Studies on anticipatory planning of object manipulation showed initial task failure (i.e., object roll) when visual object shape cues are incongruent with other visual cues, such as weight distribution/density (e.g., symmetrically shaped object with an asymmetrical density). This suggests that shape cues override density cues. However, these studies typically only measured forces, with digit placement constrained. Recent evidence suggests that when digit placement is unconstrained, subjects modulate digit forces and placement. Thus, unconstrained digit placement might be modulated on initial trials (since it is an explicit process), but not forces (since it is an implicit process). We tested whether shape and density cues would differentially influence anticipatory planning of digit placement and forces during initial trials of a two-digit object manipulation task. Furthermore, we tested whether shape cues would override density cues when cues are incongruent. Subjects grasped and lifted an object with the aim of preventing roll. In Experiment 1, the object was symmetrically shaped, but with asymmetrical density (incongruent cues). In Experiment 2, the object was asymmetrical in shape and density (congruent cues). In Experiment 3, the object was asymmetrically shaped, but with symmetrical density (incongruent cues). Results showed differential modulation of digit placement and forces (modulation of load force but not placement), but only when shape and density cues were congruent. When shape and density cues were incongruent, we found collinear digit placement and symmetrical force sharing. This suggests that congruent and incongruent shape and density cues differentially influence anticipatory planning of digit forces and placement. Furthermore, shape cues do not always override density cues. A continuum of visual cues, such as those alluding to shape and density, need to be integrated.
Background: Cystatin C (CysC) is an endogenous cysteine protease inhibitor that can be used to assess the progression of kidney function. Recent studies demonstrate that CysC is a more specific indicator of glomerular filtration rate (GFR) than creatinine. CysC in plasma exists in multiple proteoforms. The goal of this study was to clarify the association of native CysC, CysC missing N-terminal Serine (CysC des-S), and CysC without three N-terminal residues (CysC des-SSP) with diabetic chronic kidney disease (CKD).
Results: Using mass spectrometric immunoassay, the plasma concentrations of native CysC and the two CysC truncation proteoforms were examined in 111 individuals from three groups: 33 non-diabetic controls, 34 participants with type 2 diabetes (DM) and without CKD and 44 participants with diabetic CKD. Native CysC concentrations were 1.4 fold greater in CKD compared to DM group (p = 0.02) and 1.5 fold greater in CKD compared to the control group (p = 0.001). CysC des-S concentrations were 1.55 fold greater in CKD compared to the DM group (p = 0.002) and 1.9 fold greater in CKD compared to the control group (p = 0.0002). CysC des-SSP concentrations were 1.8 fold greater in CKD compared to the DM group (p = 0.008) and 1.52 fold greater in CKD compared to the control group (p = 0.002). In addition, the concentrations of CysC proteoforms were greater in the setting of albuminuria. The truncated CysC proteoform concentrations were associated with estimated GFR independent of native CysC concentrations.
Conclusion: Our findings demonstrate a greater amount of CysC proteoforms in diabetic CKD. We therefore suggest assessing the role of cystatin C proteoforms in the progression of CKD.
Humans desire compliant robots to safely interact in dynamic environments
associated with daily activities. As surface electromyography non-invasively measures
limb motion intent and correlates with joint stiness during co-contractions,
it has been identied as a candidate for naturally controlling such robots. However,
state-of-the-art myoelectric interfaces have struggled to achieve both enhanced
functionality and long-term reliability. As demands in myoelectric interfaces trend
toward simultaneous and proportional control of compliant robots, robust processing
of multi-muscle coordinations, or synergies, plays a larger role in the success of the
control scheme. This dissertation presents a framework enhancing the utility of myoelectric
interfaces by exploiting motor skill learning and
exible muscle synergies for
reliable long-term simultaneous and proportional control of multifunctional compliant
robots. The interface is learned as a new motor skill specic to the controller,
providing long-term performance enhancements without requiring any retraining or
recalibration of the system. Moreover, the framework oers control of both motion
and stiness simultaneously for intuitive and compliant human-robot interaction. The
framework is validated through a series of experiments characterizing motor learning
properties and demonstrating control capabilities not seen previously in the literature.
The results validate the approach as a viable option to remove the trade-o
between functionality and reliability that have hindered state-of-the-art myoelectric
interfaces. Thus, this research contributes to the expansion and enhancement of myoelectric
controlled applications beyond commonly perceived anthropomorphic and
\intuitive control" constraints and into more advanced robotic systems designed for
everyday tasks.
In both areas, individual neurons were classified based on the spectrum of their spiking patterns. A large proportion of cells in the SPL that exhibited sensory condition-specific oscillatory spiking in the beta (13-30Hz) frequency band. Cells in the IPL typically had a more diverse mix of oscillatory and refractory spiking patterns during the task in response to changing sensory condition. Contrary to the assumptions made in many modelling studies, none of the cells exhibited Poisson-spiking statistics in SPL or IPL.
Evoked LFPs in both areas exhibited greater effects of target location than visual condition, though the evoked responses in the preferred reach direction were generally suppressed in the bimodal condition relative to the unimodal condition. Significant effects of target location on evoked responses were observed during the movement period of the task well.
In the frequency domain, LFP power in both cortical areas was enhanced in the beta band during the position estimation epoch of the task, indicating that LFP beta oscillations may be important for maintaining the ongoing state. This was particularly evident at the population level, with clear increase in alpha and beta power. Differences in spectral power between conditions also became apparent at the population level, with power during bimodal trials being suppressed relative to unimodal. The spike-field coherence showed confounding results in both the SPL and IPL, with no clear correlation between incidence of beta oscillations and significant beta coherence.
dexterous task was analyzed. An eye-tracking device was affixed to subjects during
sequences of null (salient center of mass) and weighted (non salient center of mass) trials
with unconstrained precision grasp. Subjects experienced both expected and unexpected
perturbations, with the task of minimizing object roll. Unexpected perturbations were
controlled by switching weights between trials, expected perturbations were controlled by
asking subjects to rotate the object themselves. In all cases subjects were able to
minimize the roll of the object within three trials. Eye fixations were correlated with
object weight for the initial context and for known shifts in center of mass. In subsequent
trials with unexpected weight shifts, subjects appeared to scan areas of interest from both
contexts even after learning present orientation.
The human hand has so many degrees of freedom that it may seem impossible to control. A potential solution to this problem is “synergy control” which combines dimensionality reduction with great flexibility. With applicability to a wide range of tasks, this has become a very popular concept. In this review, we describe the evolution of the modern concept using studies of kinematic and force synergies in human hand control, neurophysiology of cortical and spinal neurons, and electromyographic (EMG) activity of hand muscles. We go beyond the often purely descriptive usage of synergy by reviewing the organization of the underlying neuronal circuitry in order to propose mechanistic explanations for various observed synergy phenomena. Finally, we propose a theoretical framework to reconcile important and still debated concepts such as the definitions of “fixed” vs. “flexible” synergies and mechanisms underlying the combination of synergies for hand control.
Insulin-like growth factor 1 (IGF1) is an important biomarker for the management of growth hormone disorders. Recently there has been rising interest in deploying mass spectrometric (MS) methods of detection for measuring IGF1. However, widespread clinical adoption of any MS-based IGF1 assay will require increased throughput and speed to justify the costs of analyses, and robust industrial platforms that are reproducible across laboratories. Presented here is an MS-based quantitative IGF1 assay with performance rating of >1,000 samples/day, and a capability of quantifying IGF1 point mutations and posttranslational modifications. The throughput of the IGF1 mass spectrometric immunoassay (MSIA) benefited from a simplified sample preparation step, IGF1 immunocapture in a tip format, and high-throughput MALDI-TOF MS analysis. The Limit of Detection and Limit of Quantification of the resulting assay were 1.5 μg/L and 5 μg/L, respectively, with intra- and inter-assay precision CVs of less than 10%, and good linearity and recovery characteristics. The IGF1 MSIA was benchmarked against commercially available IGF1 ELISA via Bland-Altman method comparison test, resulting in a slight positive bias of 16%. The IGF1 MSIA was employed in an optimized parallel workflow utilizing two pipetting robots and MALDI-TOF-MS instruments synced into one-hour phases of sample preparation, extraction and MSIA pipette tip elution, MS data collection, and data processing. Using this workflow, high-throughput IGF1 quantification of 1,054 human samples was achieved in approximately 9 hours. This rate of assaying is a significant improvement over existing MS-based IGF1 assays, and is on par with that of the enzyme-based immunoassays. Furthermore, a mutation was detected in ∼1% of the samples (SNP: rs17884626, creating an A→T substitution at position 67 of the IGF1), demonstrating the capability of IGF1 MSIA to detect point mutations and posttranslational modifications.
Pure coconut oil, lanolin, and acetaminophen were vaporized at rates of 1–50 mg/min, using a porous network exhibiting a temperature gradient from 5000 to 5500 K/mm, without incurring noticeable chemical changes due to combustion, oxidation, or other thermally-induced chemical structural changes. The newly coined term “ereptiospiration” is used here to describe this combination of thermal transpiration at high temperature gradients since the process can force the creation of thermal aerosols by rapid heating in a localized zone. Experimental data were generated for these materials using two different supports for metering the materials to the battery powered coil: namely, a stainless steel fiber bundle and a 3-D printed steel cartridge. Heating coconut oil, lanolin, or acetaminophen in a beaker to lower temperatures than those achieved at the surface of the coil showed noticeable and rapid degradation in the samples, while visual and olfactory observations for ereptiospiration showed no noticeable degradation in lanolin and coconut oil while HPLC chromatograms along with visual observation confirm that within the limit of detection, acetaminophen remains chemically unaltered by ereptiospiration.