This collection includes both ASU Theses and Dissertations, submitted by graduate students, and the Barrett, Honors College theses submitted by undergraduate students. 

Displaying 1 - 10 of 26
Filtering by

Clear all filters

150162-Thumbnail Image.png
Description
Disinfection byproducts are the result of reactions between natural organic matter (NOM) and a disinfectant. The formation and speciation of DBP formation is largely dependent on the disinfectant used and the natural organic matter (NOM) concentration and composition. This study examined the use of photocatalysis with titanium dioxide for the

Disinfection byproducts are the result of reactions between natural organic matter (NOM) and a disinfectant. The formation and speciation of DBP formation is largely dependent on the disinfectant used and the natural organic matter (NOM) concentration and composition. This study examined the use of photocatalysis with titanium dioxide for the oxidation and removal of DBP precursors (NOM) and the inhibition of DBP formation. Water sources were collected from various points in the treatment process, treated with photocatalysis, and chlorinated to analyze the implications on total trihalomethane (TTHM) and the five haloacetic acids (HAA5) formations. The three sub-objectives for this study included: the comparison of enhanced and standard coagulation to photocatalysis for the removal of DBP precursors; the analysis of photocatalysis and characterization of organic matter using size exclusion chromatography and fluorescence spectroscopy and excitation-emission matrices; and the analysis of photocatalysis before GAC filtration. There were consistencies in the trends for each objective including reduced DBP precursors, measured as dissolved organic carbon DOC concentration and UV absorbance at 254 nm. Both of these parameters decreased with increased photocatalytic treatment and could be due in part to the adsorption to as well as the oxidation of NOM on the TiO2 surface. This resulted in lower THM and HAA concentrations at Medium and High photocatalytic treatment levels. However, at No UV exposure and Low photocatalytic treatment levels where oxidation reactions were inherently incomplete, there was an increase in THM and HAA formation potential, in most cases being significantly greater than those found in the raw water or Control samples. The size exclusion chromatography (SEC) results suggest that photocatalysis preferentially degrades the higher molecular mass fraction of NOM releasing lower molecular mass (LMM) compounds that have not been completely oxidized. The molecular weight distributions could explain the THM and HAA formation potentials that decreased at the No UV exposure samples but increased at Low photocatalytic treatment levels. The use of photocatalysis before GAC adsorption appears to increase bed life of the contactors; however, higher photocatalytic treatment levels have been shown to completely mineralize NOM and would therefore not require additional GAC adsorption after photocatalysis.
ContributorsDaugherty, Erin (Author) / Abbaszadegan, Morteza (Thesis advisor) / Fox, Peter (Committee member) / Mayer, Brooke (Committee member) / Arizona State University (Publisher)
Created2011
150939-Thumbnail Image.png
Description
Bacteroides have been suggested as alternative indicators of fecal pollution since they are highly abundant in feces and are thought to have limited potential to grow in environment. However, recent literature suggests that Bacteroides can potentially survive within water distribution systems. The first objective of this study was therefore to

Bacteroides have been suggested as alternative indicators of fecal pollution since they are highly abundant in feces and are thought to have limited potential to grow in environment. However, recent literature suggests that Bacteroides can potentially survive within water distribution systems. The first objective of this study was therefore to investigate the validity of Bacteroides as a fecal indicator for drinking water through laboratory experiments and field studies. Experiments were performed using a laboratory scale PVC model water distribution system that was spiked with 109 Bacteroides. Samples were collected over the following four and analyzed by culture and molecular-based techniques. Second, field studies were performed by collecting water meters from two large chlorinated water distribution systems in central Arizona. Upon removal for repair by city personnel, meters were collected and biofilms samples were gathered within two hours. The biofilms were then analyzed using culture and molecular-based assays. The results from these studies support the hypothesis that Bacteroides DNA may be found in water distribution systems despite the difficulty of cultivating these bacterial cells. These experiments present the importance of considering biofilm interactions with fecal indicator bacteria when performing molecular assays on environmental samples, as biofilms may provide protection from high oxygen concentrations and grazing protozoa in bulk water that limit the persistence Bacteroides in the environment. Although the significance of biofilm interactions with surface or recreational waters may be small, they are likely important when considering drinking water delivered through distribution systems. The second objective of this study was to investigate alternative detection methodologies for the fecal indicator Bacteroides. In particular, this study focused on using a simplified protocol of Nucleic Acid Sequence Based Amplification (NASBA) and Thermophilic Helicase-Dependent Amplification (tHDA) to amplify the highly conserved 16s rRNA gene in the genomic DNA of fecal indicator Bacteroides. The results of this study show that the simplified NASBA procedure was not able to amplify the target, while continuous problems with tHDA exposed the methods lack of reliability. These results suggest higher reliability in the isothermal amplification methods needs to be achieved before application to environmental samples.
ContributorsDunkin, Nate (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2012
171533-Thumbnail Image.png
Description
Corrosion is known to have severe infrastructure integrity implications in a broad range of industries including water and wastewater treatment and reclamation. In the U.S. alone, the total losses due to corrosion in drinking water and wastewater systems can account for economic losses as high as $80 billion dollars a

Corrosion is known to have severe infrastructure integrity implications in a broad range of industries including water and wastewater treatment and reclamation. In the U.S. alone, the total losses due to corrosion in drinking water and wastewater systems can account for economic losses as high as $80 billion dollars a year. Microbially induced corrosion is a complex phenomenon which involve various phases; 1) formation of biofilms on submerged surfaces, 2) creation of micro-environmental niches associated with biofilm growth, 3) altered availability nutrients, 4) changes in the pH and oxygen concentrations. Biofilms can harbor opportunistic or pathogenic bacteria for a long time increasing the risk of pathogen exposure for the end users. The focus of this thesis research was to study the kinetics of microbially induced corrosion of various materials in water and reclaimed water systems. The specific objective was to assess the biofilms formation potential on stainless steel 304, stainless steel 316, galvanized steel, copper, cPVC, glass, carbon steel, and cast iron in water and reclaimed water systems. Experiments were conducted using bioreactor containers, each bioreactor housed four sampling boxes with eight partitions, dedicated to each material type coupon. One bioreactor was stationed at ASU, and one at Vistancia Aquifer Storage and Recovery (ASR) well; while three bioreactors were stationed at Butler facility, at pre-disinfection, post-UV and post-chlorination. From each location, one submerged sampling box was retrieved after 1, 3, 6 and 12 months. Time series of biofilm samples recovered from various types of coupons from different locations were analyzed using physical and culture-based techniques for quantification of biofilms and detection of heterotrophic plate count (HPC) bacteria, Legionella, Mycobacterium, and sulfate reducing bacteria (SRB). After one-year, galvanized steel had the highest concentration of HPC at 4.27 logs while copper had the lowest concentration of 3.08 logs of HPC. Bacterial growth data collected from the SRB tests was compiled to develop a numerical matrix using growth potential, biofilm formation potential and metal reduction potential of SRB isolates. This risk assessment matrix can be a useful tool for the water industry to evaluate the potential risk of MIC in their systems.
ContributorsNeal, Amber (Author) / Abbaszadegan, Morteza (Thesis advisor) / Fox, Peter (Committee member) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2022
171558-Thumbnail Image.png
Description
Megapolitan cities have emerged due to unprecedented urban migration. These changes strain urban resources, especially water distribution and treatment systems. The recent rise of Legionella cases linked to water distribution systems highlights this issue.Bacterial growth and biofilm formation are influenced by factors, such as type and concentration of residual disinfectant,

Megapolitan cities have emerged due to unprecedented urban migration. These changes strain urban resources, especially water distribution and treatment systems. The recent rise of Legionella cases linked to water distribution systems highlights this issue.Bacterial growth and biofilm formation are influenced by factors, such as type and concentration of residual disinfectant, pipe material, water temperature. Experiments were conducted in identical model water distribution systems (WDSs) constructed of three different pipe materials: galvanized steel, copper, and cross-linked polyethylene (PEX) operated under a continuous flow rate of 15 L/min. Each model WDS includes 11 steel coupons screwed to the water distribution pipes. City of Tempe (Arizona) municipal water was used in the experimentation, with no nutrients added. Following biofilm growth, coupons were removed and processed by scrubbing biofilm into phosphate-buffered saline (PBS). Reasoner's 2A (R2A), Trypticase Soy Agar (TSA), Brilliant, and buffered charcoal yeast extract (BCYE) agar media were used to examine biofilm samples for heterotrophic plate counts (HPC), metabolically active bacteria, E coli, and Legionella. Simultaneously, water samples from the reservoirs of model WDSs were also collected and examined for the same bacteria.Next, an electrochlorination cell maintained free chlorine residuals in unheated PEX and copper model WDSs. These two systems maintained free chlorine residuals for one week and evaluated biofilm and bacterial kinetics. Higher water temperature increased biofilm development. Bacterial counts in biofilms were higher on new (fresh) coupons compared to the old coupons. Heterotrophic and metabolically active bacteria behaved similarly. Only control and heating systems in copper water reservoirs have Legionella spp. Biofilms formed less on copper systems than steel and PEX systems. Initially, PEX had more HPC than copper. After electrochlorination, HPC concentration in the PEX system rapidly declined to non-detect, whereas in the copper system dropped to 0.54 log CFU/mL. Thus, higher temperature increases biofilm growth on all pipe materials and reservoirs bacterial concentration. Electrochlorination is a potential biofilm and microbial disinfection method. This thesis topic investigated how these parameters affect the model distribution system bacterial populations and biofilm growth.
ContributorsKolahi Kouchaki, Bita (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Perreault, Francois (Committee member) / Arizona State University (Publisher)
Created2022
161990-Thumbnail Image.png
Description
The ongoing COVID pandemic has opened the doors for the development of effective surface disinfection technologies. UV technology is one of the most effective technique to be used in combination with different photocatalytic agents such as Titanium Dioxide (TiO2) for microbial inactivation. There are many bacteria and viruses which have

The ongoing COVID pandemic has opened the doors for the development of effective surface disinfection technologies. UV technology is one of the most effective technique to be used in combination with different photocatalytic agents such as Titanium Dioxide (TiO2) for microbial inactivation. There are many bacteria and viruses which have the potential to infect humans via surface-oral/inhalation pathway. Thus, it is important to evaluate the effectiveness of these techniques used to inactivate microorganisms to minimize environmental transmission. UV light directly acts on bacteria and viruses by damaging their nucleic acids and protein structures. TiO2 acts as a photocatalyst, generates hydroxyl radicals under UV, leading to enhanced inactivation efficacy. This study focuses on the impact of UVC light at 254 nm wavelength in combination with spray formulations with TiO2 for the inactivation of E. coli (exposure times of 1, 5 and 10 minutes) and bacteriophages P22 (exposure times of 5 and 10 minutes) and MS2 (exposure times of 1 and 5 minutes). This study includes tests that explored the long-lasting impact of spray formulations on non-porous surface. Minimal inactivation of ~ 0.15 log inactivation of E. coli was resulted using TiO¬2 alone but when UV was added to the procedure on average 3 log inactivation was achieved. It was noted that MS2 was found to be more susceptible to UV as compared to P22 due to its higher inactivation rate. The spray formulation homogeneity is a critical factor in consistent microbial inactivation. In addition, the UV intensity of the handheld device is an important factor for total disinfection. However, the combined spray formulation and UV technology is an effective method of surface disinfection.
ContributorsBaxi, Dhatri Kamleshbhai (Author) / Abbaszadegan, Morteza (Thesis advisor) / Fox, Peter (Committee member) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2021
156991-Thumbnail Image.png
Description
One of the two objectives of this dissertation is an investigation into the possible correlation between rainfall events and increased levels of E. coli and Mycobacterium using an existing data set. The literature states that levels of microbial concentrations do increase after rainfall events, but there are no studies to

One of the two objectives of this dissertation is an investigation into the possible correlation between rainfall events and increased levels of E. coli and Mycobacterium using an existing data set. The literature states that levels of microbial concentrations do increase after rainfall events, but there are no studies to indicate this correlation applies in any Arizona water systems. The data analyzed for the bacterial concentrations project suggested the possibility of a correlation along one river but it is not conclusive to state that any correlation exists between rainfall events and the microbial concentration for many other sites included in the analysis. This is most likely due to the highly engineered water delivery systems that are not directly impacted.

The secondary objective was to determine if there are environmental variables collected from an ongoing project which would be a good candidate for making predictions about any of the project data parameters. Of the 79 possible opportunities for the model to accurately predict the dependent variable, it showed strong statistical favorability as well as experimentally favorable results towards Dissolved Organic Carbon as the best dependent variable from the data set, resulting in an accuracy of 41%. This is relevant since Dissolved Organic Carbon is one of the most important water quality parameters of concern for drinking water treatment plants where disinfection by-products are a limiting factor. The need for further analysis and additional data collection is an obvious result from both studies. The use of hydrograph data instead of rainfall would be a logical new direction for the heavily engineered water delivery systems.
ContributorsBuell, Andrew (Author) / Fox, Peter (Thesis advisor) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2018
154188-Thumbnail Image.png
Description
Quagga Mussels (Dreissena bugensis) are an invasive species of mollusk that have established themselves within the Colorado River system of Arizona since 2007. However, despite close proximity and frequent travel by recreational boaters between reservoirs, they have not yet infested the Salt River or Verde River systems. Laboratory experimentation was

Quagga Mussels (Dreissena bugensis) are an invasive species of mollusk that have established themselves within the Colorado River system of Arizona since 2007. However, despite close proximity and frequent travel by recreational boaters between reservoirs, they have not yet infested the Salt River or Verde River systems. Laboratory experimentation was done to test the survival rate of adult D. bugensis specimens in waters collected from Bartlett Lake (Verde River), Saguaro Lake (Salt River), and Salt River Project (SRP) canals (Salt River/Verde River/Colorado River blend) as well as Central Arizona Project (CAP) canals with the addition of turbidity to simulate high runoff storm events. Under each condition, adult survival for a time period of 21 days exceeded 98%, ruling out water chemistry or turbidity as a factor. Spawning was investigated using mussels collected from Lake Pleasant in August 2015. In 4 trials of serotonin dosage between 0.5 – 1.0 mMol, spawning was not successful. Calanoid copepod predation was also investigated by field sampling at Lake Pleasant, Saguaro Lake, and Bartlett Lake during September 2015. Calanoid copepods were identified in Lake Pleasant at a density of 104.22 individuals per cubic meter at a depth of 2 meters and 9.75 individuals per cubic meter at the surface. Calanoid copepods were not found in Bartlett Lake or Saguaro Lake, ruling out copepod predation as a factor. Finally, dissolved oxygen and temperature trends were analyzed in each reservoir. While temperature profiles are similar throughout the year, seasonal drops in dissolved oxygen below survivable concentrations for D. bugensis has been observed in both Saguaro Lake and Bartlett Lake but not Lake Pleasant, representing the most plausible explanation for no observed infestation.
ContributorsSokolowski, Matthew (Author) / Fox, Peter (Thesis advisor) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2015
154207-Thumbnail Image.png
Description
Since its first report in 1976, many outbreaks linked to Legionella have been reported in the world. These outbreaks are a public health concern because of legionellosis, which is found in two forms, Pontiac fever and Legionnaires disease. Legionnaires disease is a type of pneumonia responsible for the majority of

Since its first report in 1976, many outbreaks linked to Legionella have been reported in the world. These outbreaks are a public health concern because of legionellosis, which is found in two forms, Pontiac fever and Legionnaires disease. Legionnaires disease is a type of pneumonia responsible for the majority of the illness in the reported outbreaks of legionellosis. This study consists of an extensive literature review and experimental work on the aerosolization and UV inactivation of E.coli and Legionella under laboratory conditions. The literature review summarizes Legionella general information, occurrence, environmental conditions for its survival, transmission to human, collection and detection methodologies and Legionella disinfection in air and during water treatment processes.

E. coli was used as an surrogate for Legionella in experimentation due to their similar bacterial properties such as size, gram-negative rod-shaped, un-encapsulated and non-spore-forming bacterial cells. The accessibility and non-pathogenicity of E. coli also served as factors for the substitution.

Three methods of bacterial aerosolization were examined, these included an electric spray gun, an air spray gun and a hand-held spray bottle. A set of experiments were performed to examine E. coli aerosolization and transport in the aerosolization chamber (an air tight box) placed in a Biological Safety Cabinet. Spiked sample was sprayed through the opening from one side of the aerosolization chamber using the selected aerosolization methods. The air sampler was placed at the other side to collect 100 L air sample from the aerosolization chamber. A Tryptic Soy Agar plate was placed inside the air sampler to collect and subsequently culture E. coli cells from air. Results showed that the air spray gun has the best capability of aerosolizing bacteria cells under all the conditions examined in this study compared to the other two spray methods. In this study, we provide a practical and efficient method of bacterial aerosolization technique for microbial dispersion in air. The suggested method can be used in future research for microbial dispersion and transmission studies.

A set of experiments were performed to examine UV inactivation of E. coli and Legionella cells in air. Spiked samples were sprayed through the opening from one side of the aerosolization chamber using the air spray gun. A UV-C germicidal lamp inside the Biological Safety Cabinet was turned on after each spray. The air samples were collected as previously described. The application of UV-C for the inactivation of bacterial cells resulted in removing aerosolized E. coli and Legionella cells in air. A 1 log reduction was achieved with 5 seconds UV exposure time while 10 seconds UV exposure resulted in a 2 log bacterial reduction for both bacteria. This study shows the applicability of UV inactivation of pathogenic bacterial cells in air by short UV exposure time. This method may be applicable for the inactivation of Legionella in air ducts by installing germicidal UV lamps for protecting susceptible populations in certain indoor settings such as nursing homes or other community rooms.
ContributorsYao, Wei (Author) / Abbaszadegan, Morteza (Thesis advisor) / Fox, Peter (Committee member) / Alum, Absar (Committee member) / Arizona State University (Publisher)
Created2015
154132-Thumbnail Image.png
Description
The purpose of this study was to determine the applicability of fluorescent microspheres as a surrogate to measure the removal of Cryptosporidium oocysts through the coagulation, flocculation, sedimentation, and filtration steps of conventional water treatment. In order to maintain accuracy and applicability, a local water treatment facility was chosen as

The purpose of this study was to determine the applicability of fluorescent microspheres as a surrogate to measure the removal of Cryptosporidium oocysts through the coagulation, flocculation, sedimentation, and filtration steps of conventional water treatment. In order to maintain accuracy and applicability, a local water treatment facility was chosen as the system to model. The city of Chandler Arizona utilizes conventional treatment methodologies to remove pathogens from municipal drinking water and thus the water, coagulant, polymer, and doses concentrations were sourced directly from the plant. Jar testing was performed on four combinations of coagulant, polymer, and fluorescent microsphere to determine if the log removal was similar to that of Cryptosporidium oocysts.

Complications with the material properties of the microspheres arose during testing that ultimately yielded unfavorable but conclusive results. Log removal of microspheres did not increase with added coagulant in the predicted manner, though the beads were seen aggregating, the low density of the particles made the sedimentation step inefficient. This result can be explained by the low density of the microspheres as well as the potential presence of residual coagulant present in the system. Given the unfavorable properties of the beads, they do not appear to be a suitable candidate for the surrogacy of Cryptosporidium oocysts in conventional drinking water treatment. The beads in their current state are not an adequate surrogate; however, future testing has been outlined to modify the experiment in such a way that the microspheres should behave like oocysts in terms of physical transportation.
ContributorsLinks, Alexander Glenn (Author) / Abbaszadegan, Morteza (Thesis advisor) / Alum, Absar (Committee member) / Fox, Peter (Committee member) / Arizona State University (Publisher)
Created2015
153232-Thumbnail Image.png
Description
Since its first report in 1976, many outbreaks of Legionella have been reported in the world. These outbreaks are a public health concern because of legionellosis, which cause Pontiac fever and Legionnaires disease. Legionnaires disease is a type of pneumonia responsible for the majority of the illness in

Since its first report in 1976, many outbreaks of Legionella have been reported in the world. These outbreaks are a public health concern because of legionellosis, which cause Pontiac fever and Legionnaires disease. Legionnaires disease is a type of pneumonia responsible for the majority of the illness in the reported outbreaks. This study consists of an extensive literature review and experimental work on the aerosolization of Legionella and a bacterial surrogate under laboratory conditions. The literature review summarizes Legionella characteristics, legionellosis, potential sources of Legionella, disease outbreaks, collection and detection methodologies, environmental conditions for growth and survival of Legionella, Gaussian plume dispersion modeling, and recommendations for reducing potential Legionella outbreaks. The aerosolization and airborne dispersion of Legionella and E. coli was conducted separately inside of a closed environment. First, the bacterial cells were sprayed inside of an airtight box and then samples were collected using a microbial air sampler to measure the number of bacterial cells aerosolized and transported in air. Furthermore, a Gaussian plume dispersion model was used to estimate the dispersion under the experimental conditions and parameters. The concentration of Legionella was estimated for a person inhaling the air at three different distances away from the spray. The concentration of Legionella at distances of 0.1 km, 1 km, and 10 km away from the source was predicted to be 1.7x10-1, 2.2x10-3, and 2.6x10-5 CFU/m3, respectively.
ContributorsTaghdiri, Sepideh (Author) / Abbaszadegan, Morteza (Thesis advisor) / Fox, Peter (Committee member) / Estes, Robert (Committee member) / Arizona State University (Publisher)
Created2014