This collection includes both ASU Theses and Dissertations, submitted by graduate students, and the Barrett, Honors College theses submitted by undergraduate students. 

Displaying 41 - 50 of 64
137769-Thumbnail Image.png
Description
Electrochemical sensors function by detecting electroactive species at the electrode surface of a screen printed sensor. As more force is applied, the concentration of electroactive species at the surface of the sensor increases and a larger current is measured. Thus, when all conditions including voltage are made constant, as in

Electrochemical sensors function by detecting electroactive species at the electrode surface of a screen printed sensor. As more force is applied, the concentration of electroactive species at the surface of the sensor increases and a larger current is measured. Thus, when all conditions including voltage are made constant, as in Amp i-t, a quantifiable current can be read and the force applied can be calculated. Two common electrochemical techniques in which current is measured, cyclic voltammetry(CV) and amperometric i-t(Amp i-t), were used. A compressible sensor capable of transducing a force and acquiring feedback was created.
ContributorsFeldman, Austin Marc (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Santello, Marco (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137772-Thumbnail Image.png
Description
As robots become more prevalent, the need is growing for efficient yet stable control systems for applications with humans in the loop. As such, it is a challenge for scientists and engineers to develop robust and agile systems that are capable of detecting instability in teleoperated systems. Despite how much

As robots become more prevalent, the need is growing for efficient yet stable control systems for applications with humans in the loop. As such, it is a challenge for scientists and engineers to develop robust and agile systems that are capable of detecting instability in teleoperated systems. Despite how much research has been done to characterize the spatiotemporal parameters of human arm motions for reaching and gasping, not much has been done to characterize the behavior of human arm motion in response to control errors in a system. The scope of this investigation is to investigate human corrective actions in response to error in an anthropomorphic teleoperated robot limb. Characterizing human corrective actions contributes to the development of control strategies that are capable of mitigating potential instabilities inherent in human-machine control interfaces. Characterization of human corrective actions requires the simulation of a teleoperated anthropomorphic armature and the comparison of a human subject's arm kinematics, in response to error, against the human arm kinematics without error. This was achieved using OpenGL software to simulate a teleoperated robot arm and an NDI motion tracking system to acquire the subject's arm position and orientation. Error was intermittently and programmatically introduced to the virtual robot's joints as the subject attempted to reach for several targets located around the arm. The comparison of error free human arm kinematics to error prone human arm kinematics revealed an addition of a bell shaped velocity peak into the human subject's tangential velocity profile. The size, extent, and location of the additional velocity peak depended on target location and join angle error. Some joint angle and target location combinations do not produce an additional peak but simply maintain the end effector velocity at a low value until the target is reached. Additional joint angle error parameters and degrees of freedom are needed to continue this investigation.
ContributorsBevilacqua, Vincent Frank (Author) / Artemiadis, Panagiotis (Thesis director) / Santello, Marco (Committee member) / Trimble, Steven (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2013-05
135282-Thumbnail Image.png
Description
Telestroke networks reduce disparities in acute stroke care between metropolitan primary stroke centers and remote hospitals. Current technologies used to conduct remote patient assessments have very high start-up costs, yet they cannot consistently establish quality connection in a timely manner. Smartphgones can be used for high quality video teleconferencing (HQ-VTC).

Telestroke networks reduce disparities in acute stroke care between metropolitan primary stroke centers and remote hospitals. Current technologies used to conduct remote patient assessments have very high start-up costs, yet they cannot consistently establish quality connection in a timely manner. Smartphgones can be used for high quality video teleconferencing (HQ-VTC). They are relatively inexpensive and widley used among healthcare providers. We aimed to study the reliability of HQ-VTC using smartphones for conducting the NIHSS. Two vascular neurologists (VNs) assessed 83 stroke patients with the NIHSS. The remote VN assessed patients using videoconferencing on a smartphone with the assistance of a bedside medical aide. The bedside VN rated patients ontemporaneously. Each VN was blinded to the other's NIHSS scores. We tested the inter-method agreement and physician satisfaction with the device. We demonstrated high total NIHSS score correlation between the methods (r=0.941, p<0.001). The mean total NIHSS scores for bedside and remote assessments were 7.3 plus or minus 7.9 and 6.7 plus or minus 7.6 with ranges of 0-30 and 0-37, respectively. Seven NIHSS categories had significantly high agreement beyond chance: LOC-questions, LOC-commands, visual fields, motor left arm, motor right arm, motor left leg, motor right leg; seven categories had moderate agreement: LOC-consciousness, best gaze, facial palsy, sensory, best language, dysarthria, extinction/inattention; one category had poor agreement: ataxia. There was high physician satisfaction with the device. The VNs rated 96% of the assessments as good or very good for "image quality," "sound quality," "ease of use," and "ability to assess subject using NIHSS," and 84% of the assesssments as good or very good for "reception in hospital." The smartphones with HQ-VTC is reliable, easy to use, and affordable for telestroke NIHSS administration. This device has high physician satisfaction. With the variety of smartphones and professional medical applications available today, the telestroke practitioner has all the tools necessary for fast clinical decision-makingby accessing electronic medial records, viewing images, and tracking patient vitals.
ContributorsVegunta, Sravanthi (Author) / Demaerschalk, Bart (Thesis director) / Santello, Marco (Committee member) / Hurlbut, Ben (Committee member) / Barrett, The Honors College (Contributor)
Created2012-05
168329-Thumbnail Image.png
Description
Repetitive practice of functional movement patterns during motor rehabilitation are known to drive learning (or relearning) of novel motor skills, but the learning process is highly variable between individuals such that responsiveness to task-specific training is often patient-specific. A number of neuroimaging and neurophysiological methods have been proposed to better

Repetitive practice of functional movement patterns during motor rehabilitation are known to drive learning (or relearning) of novel motor skills, but the learning process is highly variable between individuals such that responsiveness to task-specific training is often patient-specific. A number of neuroimaging and neurophysiological methods have been proposed to better predict a patient’s responsiveness to a given type or dose of motor therapy. However, these methods are often time- and resource-intensive, and yield results that are not readily interpretable by clinicians. In contrast, standardized visuospatial tests may offer a more feasible solution. The work presented in this dissertation demonstrate that a clinical paper-and-pencil test of visuospatial function may improve predictive models of motor skill learning in older adults and individuals with stroke pathology. To further our understanding of the neuroanatomical correlates underlying this behavioral relationship, I collected diffusion-weighted magnetic resonance images from 19 nondemented older adults to determine if diffusion characteristics of white matter tracts explain shared variance in delayed visuospatial memory test scores and motor skill learning. Consistent with previous work, results indicated that the structural integrity of regions with the bilateral anterior thalamic radiations, corticospinal tracts, and superior longitudinal fasciculi are related to delayed visuospatial memory performance and one-week skill retention. Overall, results of this dissertation suggest that incorporating a clinical paper-and-pencil test of delayed visuospatial memory may prognose motor rehabilitation outcomes and support that personalized variables should be considered in standards of care. Moreover, regions within specific white matter tracts may underlie this behavioral relationship and future work should investigate these regions as potential targets for therapeutic intervention.
ContributorsLingo VanGilder, Jennapher (Author) / Schaefer, Sydney Y (Thesis advisor) / Santello, Marco (Committee member) / Buneo, Christopher (Committee member) / Rogalsky, Corianne (Committee member) / Duff, Kevin (Committee member) / Arizona State University (Publisher)
Created2021
168487-Thumbnail Image.png
Description
Information processing in the brain is mediated by network interactions between anatomically distant (centimeters apart) regions of cortex and network action is fundamental to human behavior. Disruptive activity of these networks may allow a variety of diseases to develop. Degradation or loss of network function in the brain can affect

Information processing in the brain is mediated by network interactions between anatomically distant (centimeters apart) regions of cortex and network action is fundamental to human behavior. Disruptive activity of these networks may allow a variety of diseases to develop. Degradation or loss of network function in the brain can affect many aspects of the human experience; motor disorder, language difficulties, memory loss, mood swings, and more. The cortico-basal ganglia loop is a system of networks in the brain between the cortex, basal ganglia, the thalamus, and back to the cortex. It is not one singular circuit, but rather a series of parallel circuits that are relevant towards motor output, motor planning, and motivation and reward. Studying the relationship between basal ganglia neurons and cortical local field potentials may lead to insights about neurodegenerative diseases and how these diseases change the cortico-basal ganglia circuit. Speech and language are uniquely human and require the coactivation of several brain regions. The various aspects of language are spread over the temporal lobe and parts of the occipital, parietal, and frontal lobe. However, the core network for speech production involves collaboration between phonologic retrieval (encoding ideas into syllabic representations) from Wernicke’s area, and phonemic encoding (translating syllables into motor articulations) from Broca’s area. Studying the coactivation of these brain regions during a repetitive speech production task may lead to a greater understanding of their electrophysiological functional connectivity. The primary purpose of the work presented in this document is to validate the use of subdural microelectrodes in electrophysiological functional connectivity research as these devices best match the spatial and temporal scales of brain activity. Neuron populations in the cortex are organized into functional units called cortical columns. These cortical columns operate on the sub-millisecond temporal and millimeter spatial scale. The study of brain networks, both in healthy and unwell individuals, may reveal new methodologies of treatment or management for disease and injury, as well as contribute to our scientific understanding of how the brain works.
ContributorsO'Neill, Kevin John (Author) / Greger, Bradley (Thesis advisor) / Santello, Marco (Committee member) / Helms Tillery, Stephen (Committee member) / Papandreou-Suppapola, Antonia (Committee member) / Kleim, Jeffery (Committee member) / Arizona State University (Publisher)
Created2021
189324-Thumbnail Image.png
Description
A current thrust in neurorehabilitation research involves exogenous neuromodulation of peripheral nerves to enhance neuroplasticity and maximize recovery of function. This dissertation presents the results of four experiments aimed at assessing the effects of trigeminal nerve stimulation (TNS) and occipital nerve stimulation (ONS) on motor learning, which was behaviorally characterized

A current thrust in neurorehabilitation research involves exogenous neuromodulation of peripheral nerves to enhance neuroplasticity and maximize recovery of function. This dissertation presents the results of four experiments aimed at assessing the effects of trigeminal nerve stimulation (TNS) and occipital nerve stimulation (ONS) on motor learning, which was behaviorally characterized using an upper extremity visuomotor adaptation paradigm. In Aim 1a, the effects of offline TNS using clinically tested frequencies (120 and 60 Hz) were characterized. Sixty-three participants (22.75±4.6 y/o), performed a visuomotor rotation task and received TNS before encountering rotation of hand visual feedback. In Aim 1b, TNS at 3 kHz, which has been shown to be more tolerable at higher current intensities, was evaluated in 42 additional subjects (23.4±4.6 y/o). Results indicated that 3 kHz stimulation accelerated learning while 60 Hz stimulation slowed learning, suggesting a frequency-dependent effect on learning. In Aim 2, the effect of online TNS using 120 and 60 Hz were characterized to determine if this protocol would deliver better outcomes. Sixty-three participants (23.2±3.9 y/o) received either TNS or sham concurrently with perturbed visual feedback. Results showed no significant differences among groups. However, a cross-study comparison of results obtained with 60 Hz offline TNS showed a statistically significant improvement in learning rates with online stimulation relative to offline, suggesting a timing-dependent effect on learning. In Aim 3, TNS and ONS were compared using the best protocol from previous aims (offline 3 kHz). Additionally, concurrent stimulation of both nerves was explored to look for potential synergistic effects. Eighty-four participants (22.9±3.2 y/o) were assigned to one of four groups: TNS, ONS, TNS+ONS, and sham. Visual inspection of learning curves revealed that the ONS group demonstrated the fastest learning among groups. However, statistical analyses did not confirm this observation. In addition, the TNS+ONS group appeared to learn faster than the sham and TNS groups but slower than the ONS only group, suggesting no synergistic effects using this protocol, as initially hypothesized. The results provide new information on the potential use of TNS and ONS in neurorehabilitation and performance enhancement in the motor domain.
ContributorsArias, Diego (Author) / Buneo, Christopher (Thesis advisor) / Schaefer, Sydney (Committee member) / Helms-Tillery, Stephen (Committee member) / Santello, Marco (Committee member) / Kleim, Jeffrey (Committee member) / Arizona State University (Publisher)
Created2023
187872-Thumbnail Image.png
Description
Multisensory integration is the process by which information from different sensory modalities is integrated by the nervous system. This process is important not only from a basic science perspective but also for translational reasons, e.g., for the development of closed-loop neural prosthetic systems. A mixed virtual reality platform was developed

Multisensory integration is the process by which information from different sensory modalities is integrated by the nervous system. This process is important not only from a basic science perspective but also for translational reasons, e.g., for the development of closed-loop neural prosthetic systems. A mixed virtual reality platform was developed to study the neural mechanisms of multisensory integration for the upper limb during motor planning. The platform allows for selection of different arms and manipulation of the locations of physical and virtual target cues in the environment. The system was tested with two non-human primates (NHP) trained to reach to multiple virtual targets. Arm kinematic data as well as neural spiking data from primary motor (M1) and dorsal premotor cortex (PMd) were collected. The task involved manipulating visual information about initial arm position by rendering the virtual avatar arm in either its actual position (veridical (V) condition) or in a different shifted (e.g., small vs large shifts) position (perturbed (P) condition) prior to movement. Tactile feedback was modulated in blocks by placing or removing the physical start cue on the table (tactile (T), and no-tactile (NT) conditions, respectively). Behaviorally, errors in initial movement direction were larger when the physical start cue was absent. Slightly larger directional errors were found in the P condition compared to the V condition for some movement directions. Both effects were consistent with the idea that erroneous or reduced information about initial hand location led to movement direction-dependent reach planning errors. Neural correlates of these behavioral effects were probed using population decoding techniques. For small shifts in the visual position of the arm, no differences in decoding accuracy between the T and NT conditions were observed in either M1 or PMd. However, for larger visual shifts, decoding accuracy decreased in the NT condition, but only in PMd. Thus, activity in PMd, but not M1, may reflect the uncertainty in reach planning that results when sensory cues regarding initial hand position are erroneous or absent.
ContributorsPhataraphruk, Preyaporn Kris (Author) / Buneo, Christopher A (Thesis advisor) / Zhou, Yi (Committee member) / Helms Tillery, Steve (Committee member) / Greger, Bradley (Committee member) / Santello, Marco (Committee member) / Arizona State University (Publisher)
Created2023
156204-Thumbnail Image.png
Description
The human hand comprises complex sensorimotor functions that can be impaired by neurological diseases and traumatic injuries. Effective rehabilitation can bring the impaired hand back to a functional state because of the plasticity of the central nervous system to relearn and remodel the lost synapses in the brain. Current rehabilitation

The human hand comprises complex sensorimotor functions that can be impaired by neurological diseases and traumatic injuries. Effective rehabilitation can bring the impaired hand back to a functional state because of the plasticity of the central nervous system to relearn and remodel the lost synapses in the brain. Current rehabilitation therapies focus on strengthening motor skills, such as grasping, employ multiple objects of varying stiffness and devices that are bulky, costly, and have limited range of stiffness due to the rigid mechanisms employed in their variable stiffness actuators. This research project presents a portable cost-effective soft robotic haptic device with a broad stiffness range that is adjustable and can be utilized in both clinical and home settings. The device eliminates the need for multiple objects by employing a pneumatic soft structure made with highly compliant materials that act as the actuator as well as the structure of the haptic interface. It is made with interchangeable soft elastomeric sleeves that can be customized to include materials of varying stiffness to increase or decrease the stiffness range. The device is fabricated using existing 3D printing technologies, and polymer molding and casting techniques, thus keeping the cost low and throughput high. The haptic interface is linked to either an open-loop system that allows for an increased pressure during usage or closed-loop system that provides pressure regulation in accordance with the stiffness the user specifies. A preliminary evaluation is performed to characterize the effective controllable region of variance in stiffness. Results indicate that the region of controllable stiffness was in the center of the device, where the stiffness appeared to plateau with each increase in pressure. The two control systems are tested to derive relationships between internal pressure, grasping force exertion on the surface, and displacement using multiple probing points on the haptic device. Additional quantitative evaluation is performed with study participants and juxtaposed to a qualitative analysis to ensure adequate perception in compliance variance. Finally, a qualitative evaluation showed that greater than 60% of the trials resulted in the correct perception of stiffness in the haptic device.
ContributorsSebastian, Frederick (Author) / Polygerinos, Panagiotis (Thesis advisor) / Santello, Marco (Committee member) / Fu, Qiushi (Committee member) / Arizona State University (Publisher)
Created2018
187370-Thumbnail Image.png
Description
This project investigates the gleam-glum effect, a well-replicated phonetic emotion association in which words with the [i] vowel-sound (as in “gleam”) are judged more emotionally positive than words with the [Ʌ] vowel-sound (as in “glum”). The effect is observed across different modalities and languages and is moderated by mouth movements

This project investigates the gleam-glum effect, a well-replicated phonetic emotion association in which words with the [i] vowel-sound (as in “gleam”) are judged more emotionally positive than words with the [Ʌ] vowel-sound (as in “glum”). The effect is observed across different modalities and languages and is moderated by mouth movements relevant to word production. This research presents and tests an articulatory explanation for this association in three experiments. Experiment 1 supported the articulatory explanation by comparing recordings of 71 participants completing an emotional recall task and a word read-aloud task, showing that oral movements were more similar between positive emotional expressions and [i] articulation, and negative emotional expressions and [Ʌ] articulation. Experiment 2 partially supported the explanation with 98 YouTube recordings of natural speech. In Experiment 3, 149 participants judged emotions expressed by a speaker during [i] and [Ʌ] articulation. Contradicting the robust phonetic emotion association, participants judged more frequently that the speaker’s [Ʌ] articulatory movements were positive emotional expressions and [i] articulatory movements were negative emotional expressions. This is likely due to other visual emotional cues not related to oral movements and the order of word lists read by the speaker. Findings from the current project overall support an articulatory explanation for the gleam-glum effect, which has major implications for language and communication.
ContributorsYu, Shin-Phing (Author) / Mcbeath, Michael K (Thesis advisor) / Glenberg, Arthur M (Committee member) / Stone, Greg O (Committee member) / Coza, Aurel (Committee member) / Santello, Marco (Committee member) / Arizona State University (Publisher)
Created2023
171660-Thumbnail Image.png
Description
With an aging population, the number of later in life health related incidents like stroke stand to become more prevalent. Unfortunately, the majority those who are most at risk for debilitating heath episodes are either uninsured or under insured when it comes to long term physical/occupational therapy. As insurance companies

With an aging population, the number of later in life health related incidents like stroke stand to become more prevalent. Unfortunately, the majority those who are most at risk for debilitating heath episodes are either uninsured or under insured when it comes to long term physical/occupational therapy. As insurance companies lower coverage and/or raise prices of plans with sufficient coverage, it can be expected that the proportion of uninsured/under insured to fully insured people will rise. To address this, lower cost alternative methods of treatment must be developed so people can obtain the treated required for a sufficient recovery. The presented robotic glove employs low cost fabric soft pneumatic actuators which use a closed loop feedback controller based on readings from embedded soft sensors. This provides the device with proprioceptive abilities for the dynamic control of each independent actuator. Force and fatigue tests were performed to determine the viability of the actuator design. A Box and Block test along with a motion capture study was completed to study the performance of the device. This paper presents the design and classification of a soft robotic glove with a feedback controller as a at-home stroke rehabilitation device.
ContributorsAxman, Reed C (Author) / Zhang, Wenlong (Thesis advisor) / Santello, Marco (Committee member) / McDaniel, Troy (Committee member) / Arizona State University (Publisher)
Created2022