This collection includes both ASU Theses and Dissertations, submitted by graduate students, and the Barrett, Honors College theses submitted by undergraduate students. 

Displaying 1 - 10 of 14
Filtering by

Clear all filters

Description

Visual odometry (VO) plays a crucial role in determining the position and orientation of an autonomous vehicle as it navigates through its environment. However, the performance of visual odometry can be significantly affected by errors in disparity estimation and LIDAR depth measurements. This thesis investigates the use of LIDAR depth

Visual odometry (VO) plays a crucial role in determining the position and orientation of an autonomous vehicle as it navigates through its environment. However, the performance of visual odometry can be significantly affected by errors in disparity estimation and LIDAR depth measurements. This thesis investigates the use of LIDAR depth correction and Stereo disparity matching, combined with stronger match filtering, to improve the accuracy and reliability of VO estimations. The study utilizes a dataset consisting of a sequence of image frames, ground truth position data, and a range of feature detection, description, and matching techniques. Results indicate that the proposed approach significantly improves the accuracy of VO estimations, providing a valuable contribution to the development of reliable and safe autonomous navigation systems. The proposed method consists of two main components: (1) an advanced disparity matching algorithm to obtain more accurate and robust disparity estimations, and (2) a LIDAR depth correction module that employs a sensor fusion approach to refine the depth information generated by LIDAR sensors. The LIDAR depth correction module combines data from multiple sensors, including LIDAR, camera, and inertial measurement unit (IMU), to produce a more accurate depth estimation. The performance of the proposed approach is evaluated using real-world datasets and benchmark visual odometry challenges. Results demonstrate that the proposed method significantly improves the accuracy and robustness of visual odometry, leading to better localization and navigation performance for autonomous vehicles. This research contributes to the ongoing development of autonomous vehicle technology by addressing critical challenges in visual odometry and offering a practical solution for more accurate and reliable self-localization

ContributorsThanga Raj, Tilak Raj (Author) / Zhang, Wenlong (Thesis director) / Sugar, Thomas (Committee member) / Barrett, The Honors College (Contributor) / School of Mathematical and Statistical Sciences (Contributor) / Engineering Programs (Contributor)
Created2023-05
157404-Thumbnail Image.png
Description
This thesis presents the design and testing of a soft robotic device for water utility pipeline inspection. The preliminary findings of this new approach to conventional methods of pipe inspection demonstrate that a soft inflatable robot can successfully traverse the interior space of a range of diameter pipes using pneumatic

This thesis presents the design and testing of a soft robotic device for water utility pipeline inspection. The preliminary findings of this new approach to conventional methods of pipe inspection demonstrate that a soft inflatable robot can successfully traverse the interior space of a range of diameter pipes using pneumatic and without the need to adjust rigid, mechanical components. The robot utilizes inflatable soft actuators with an adjustable radius which, when pressurized, can provide a radial force, effectively anchoring the device in place. Additional soft inflatable actuators translate forces along the center axis of the device which creates forward locomotion when used in conjunction with the radial actuation. Furthermore, a bio-inspired control algorithm for locomotion allows the robot to maneuver through a pipe by mimicking the peristaltic gait of an inchworm. This thesis provides an examination and evaluation of the structure and behavior of the inflatable actuators through computational modeling of the material and design, as well as the experimental data of the forces and displacements generated by the actuators. The theoretical results are contrasted with/against experimental data utilizing a physical prototype of the soft robot. The design is anticipated to enable compliant robots to conform to the space offered to them and overcome occlusions from accumulated solids found in pipes. The intent of the device is to be used for inspecting existing pipelines owned and operated by Salt River Project, a Phoenix-area water and electricity utility provider.
ContributorsAdams, Wade Silas (Author) / Aukes, Daniel (Thesis advisor) / Sugar, Thomas (Committee member) / Zhang, Wenlong (Committee member) / Arizona State University (Publisher)
Created2019
189365-Thumbnail Image.png
Description
While wearable soft robots have successfully addressed many inherent design limitations faced by wearable rigid robots, they possess a unique set of challenges due to their soft and compliant nature. Some of these challenges are present in the sensing, modeling, control and evaluation of wearable soft robots. Machine learning algorithms

While wearable soft robots have successfully addressed many inherent design limitations faced by wearable rigid robots, they possess a unique set of challenges due to their soft and compliant nature. Some of these challenges are present in the sensing, modeling, control and evaluation of wearable soft robots. Machine learning algorithms have shown promising results for sensor fusion with wearable robots, however, they require extensive data to train models for different users and experimental conditions. Modeling soft sensors and actuators require characterizing non-linearity and hysteresis, which complicates deriving an analytical model. Experimental characterization can capture the characteristics of non-linearity and hysteresis but requires developing a synthesized model for real-time control. Controllers for wearable soft robots must be robust to compensate for unknown disturbances that arise from the soft robot and its interaction with the user. Since developing dynamic models for soft robots is complex, inaccuracies that arise from the unmodeled dynamics lead to significant disturbances that the controller needs to compensate for. In addition, obtaining a physical model of the human-robot interaction is complex due to unknown human dynamics during walking. Finally, the performance of soft robots for wearable applications requires extensive experimental evaluation to analyze the benefits for the user. To address these challenges, this dissertation focuses on the sensing, modeling, control and evaluation of soft robots for wearable applications. A model-based sensor fusion algorithm is proposed to improve the estimation of human joint kinematics, with a soft flexible robot that requires compact and lightweight sensors. To overcome limitations with rigid sensors, an inflatable soft haptic sensor is developed to enable gait sensing and haptic feedback. Through experimental characterization, a mathematical model is derived to quantify the user's ground reaction forces and the delivered haptic force. Lastly, the performance of a wearable soft exosuit in assisting human users during lifting tasks is evaluated, and the benefits obtained from the soft robot assistance are analyzed.
ContributorsQuiñones Yumbla, Emiliano (Author) / Zhang, Wenlong (Thesis advisor) / Berman, Spring (Committee member) / Lee, Hyunglae (Committee member) / Marvi, Hamid (Committee member) / Sugar, Thomas (Committee member) / Arizona State University (Publisher)
Created2023
158469-Thumbnail Image.png
Description
As the world population continues to age, the demand for treatment and rehabilitation of long-term age-related ailments will rise. Healthcare technology must keep up with this demand, and existing solutions must become more readily available to the populace. Conditions such as impairment due to stroke currently take months or years

As the world population continues to age, the demand for treatment and rehabilitation of long-term age-related ailments will rise. Healthcare technology must keep up with this demand, and existing solutions must become more readily available to the populace. Conditions such as impairment due to stroke currently take months or years of physical therapy to overcome, but rehabilitative exoskeletons can be used to greatly extend a physical therapist’s capabilities.

In this thesis, a rehabilitative knee exoskeleton was designed which is significantly lighter, more portable and less costly to manufacture than existing designs. It accomplishes this performance by making use of high-powered and weight-optimized brushless DC (BLDC) electric motors designed for drones, open-source hardware and software solutions for robotic motion control, and rapid prototyping technologies such as 3D printing and laser cutting.

The exoskeleton is made from a series of laser cut aluminum plates spaced apart with off-the-shelf standoffs. A drone motor with a torque of 1.32 Nm powers an 18.5:1 reduction two-stage belt drive, giving a maximum torque of 24.4 Nm at the output. The bearings for the belt drive are installed into 3D printed bearing mounts, which act as a snug intermediary between the bearing and the aluminum plate. The system is powered off a 24 volt, 1,500 MAh lithium battery, which can provide power for around an hour of walking activity.

The exoskeleton is controlled with an ODrive motor controller connected to a Raspberry Pi. Hip angle data is provided by an IMU, and the knee angle is provided by an encoder on the output shaft. A compact Rotary Series Elastic Actuator (cRSEA) device is mounted on the output shaft as well, to accurately measure the output torque going to the wearer. A Proportional-Derivative (PD) controller with feedforward relates the input current with the output torque. The device was tested on a treadmill and found to have an average backdrive torque of 0.39 Nm, significantly lower than the current state of the art. A gravity compensation controller and impedance controller were implemented to assist during swing and stance phases respectively. The results were compared to the muscular exertion of the knee measured via Electromyography (EMG).
ContributorsParmentier, Robin W (Author) / Zhang, Wenlong (Thesis advisor) / Sugar, Thomas (Committee member) / Lee, Hyunglae (Committee member) / Arizona State University (Publisher)
Created2020
158470-Thumbnail Image.png
Description
Traditionally, wearable exoskeletons for gait assistance have addressed the issue of high power requirement of providing support during walking. However, exoskeletons often are bulky, and suffer from misalignment of joints between the robot and the user. Soft robots in recent work have shown the ability to provide a high degree

Traditionally, wearable exoskeletons for gait assistance have addressed the issue of high power requirement of providing support during walking. However, exoskeletons often are bulky, and suffer from misalignment of joints between the robot and the user. Soft robots in recent work have shown the ability to provide a high degree of compliance with a light weight and lower cost. This work presents the design, control, and evaluation of a soft inflatable exosuit to assist knee extension. First, the design of novel soft inflatable actuators of I cross-section and their application in the soft inflatable exosuit is presented. The actuators are applied to a soft and lightweight garment interface to assist in knee extension during the swing phase demonstrating reduced muscle activity for the quadriceps. Second, the control of the soft exosuit is presented with the introduction of a knee angle measurement system and smart shoe insole sensors. A new control method using human joint stiffness models as well as actuator models is developed. The new control method is evaluated with three users and a reduction in the sEMG activity of the quadriceps is observed with an increase in the activity of the hamstrings. Third, an improved version of the exosuit and a controller to assist knee extension in swing phase and initial stance are presented. The exosuit is applied to seven healthy and three impaired participants. Kinematics, muscle activity and gait compensations are studied. Reduced muscle activity for the quadriceps is seen in healthy participants with reduced execution times for functional activities such as timed up-and-go as well as sit-to-stand transitions in impaired participants. Finally, an untethered version of the soft exosuit using inflatable actuator composites and a portable pneumatic source are presented. Finite element models for the composites and inflatable actuators are generated and the actuators are characterized for performance. The design of a portable source for the exosuit is also presented. The inflatable actuator composites and the portable source are implemented in a portable exosuit system which demonstrated a reduction in the Vastus Lateralis activity during incline walking for three participants. Overall, this work investigated the feasibility of several versions of the soft exosuit for gait assistance.
ContributorsSridar, Saivimal (Author) / Zhang, Wenlong (Thesis advisor) / Sugar, Thomas (Committee member) / Lockhart, Thurmon (Committee member) / Arizona State University (Publisher)
Created2020
Description
Bicycles and motorcycles offer maneuverability, energy efficiency and acceleration that four wheeled vehicles cannot offer given similar budget for. Two wheeled vehicles have drastically different dynamics from four wheeled vehicles due to their instability and gyroscopic effect from their wheels.

This thesis focuses on self-stabilization of a motorcycle using an

Bicycles and motorcycles offer maneuverability, energy efficiency and acceleration that four wheeled vehicles cannot offer given similar budget for. Two wheeled vehicles have drastically different dynamics from four wheeled vehicles due to their instability and gyroscopic effect from their wheels.

This thesis focuses on self-stabilization of a motorcycle using an active control momentum gyroscope (CMG) and validation of this multi-degree-of-freedom system’s mathematical model. Physical platform was created to mimic the simulation as accurately as possible and all components used were justified. This process involves derivation of a 3 Degree-of-Freedom (DOF) system’s forward kinematics and its Jacobian matrix, simulation analysis of different controller algorithms, setting the system and subsystem specifications, and real system experimentation and data analysis.

A Jacobian matrix was used to calculate accurately decomposed resultant angular velocities which are used to create the dynamics model of the system torque using the Euler-Lagrange method. This produces a nonlinear second order differential equation that is modeled using MATLAB/Simulink. PID, and cascaded feedback loop are tested in this Simulink model. Cascaded feedback loop shows most promises in the simulation analysis. Therefore, system specifications are calculated according to the data produced by this controller method. The model validation is executed using the Vicon motion capture system which captured the roll angle of the motorcycle. This work contributes to creating a set of procedures for creating a validated dynamic model for a CMG stabilized motorcycle which can be used to create variants of other self-stabilizing motorcycle system.
ContributorsMoon, Hansol (Author) / Zhang, Wenlong (Thesis advisor) / Frank, Daniel (Committee member) / Delp, Deana (Committee member) / Sugar, Thomas (Committee member) / Arizona State University (Publisher)
Created2020
161730-Thumbnail Image.png
Description
Robotic assisted devices in gait rehabilitation have not seen penetration into clinical settings proportionate to the developments in this field. A possible reason for this is due to the development and evaluation of these devices from a predominantly engineering perspective. One way to mitigate this effect is to further include

Robotic assisted devices in gait rehabilitation have not seen penetration into clinical settings proportionate to the developments in this field. A possible reason for this is due to the development and evaluation of these devices from a predominantly engineering perspective. One way to mitigate this effect is to further include the principles of neurophysiology into the development of these systems. To further include these principles, this research proposes a method for grounded evaluation of three machine learning algorithms to gain insight on what modeling approaches are able to both replicate therapist assistance and emulate therapist strategies. The algorithms evaluated in this paper include ordinary least squares regression (OLS), gaussian process regression (GPR) and inverse reinforcement learning (IRL). The results show that grounded evaluation is able to provide evidence to support the algorithms at a higher resolution. Also, it was observed that GPR is likely the most accurate algorithm to replicate therapist assistance and to emulate therapist adaptation strategies.
ContributorsSmith, Mason Owen (Author) / Zhang, Wenlong (Thesis advisor) / Ben Amor, Hani (Committee member) / Sugar, Thomas (Committee member) / Arizona State University (Publisher)
Created2021
161712-Thumbnail Image.png
Description
This dissertation studies the methods to enhance the performance of foldable robots manufactured by laminated techniques. This class of robots are unique in their manufacturing process, which involves cutting and staking up thin layers of different materials with various stiffness. While inheriting the advantages of soft robots -- low

This dissertation studies the methods to enhance the performance of foldable robots manufactured by laminated techniques. This class of robots are unique in their manufacturing process, which involves cutting and staking up thin layers of different materials with various stiffness. While inheriting the advantages of soft robots -- low weight, affordable manufacturing cost and a fast prototyping process -- a wider range of actuators is available to these mechanisms, while modeling their behavior requires less computational cost.The fundamental question this dissertation strives to answer is how to decode and leverage the effect of material stiffness in these robots. These robots' stiffness is relatively limited due to their slender design, specifically at larger scales. While compliant robots may have inherent advantages such as being safer to work around, this low rigidity makes modeling more complex. This complexity is mostly contained in material deformation since the conventional actuators such as servo motors can be easily leveraged in these robots. As a result, when introduced to real-world environments, efficient modeling and control of these robots are more achievable than conventional soft robots. Various approaches have been taken to design, model, and control a variety of laminate robot platforms by investigating the effect of material deformation in prototypes while they interact with their working environments. The results obtained show that data-driven approaches such as experimental identification and machine learning techniques are more reliable in modeling and control of these mechanisms. Also, machine learning techniques for training robots in non-ideal experimental setups that encounter the uncertainties of real-world environments can be leveraged to find effective gaits with high performance. Our studies on the effect of stiffness of thin, curved sheets of materials has evolved into introducing a new class of soft elements which we call Soft, Curved, Reconfigurable, Anisotropic Mechanisms (SCRAMs). Like bio-mechanical systems, SCRAMs are capable of re-configuring the stiffness of curved surfaces to enhance their performance and adaptability. Finally, the findings of this thesis show promising opportunities for foldable robots to become an alternative for conventional soft robots since they still offer similar advantages in a fraction of computational expense.
ContributorsSharifzadeh, Mohammad (Author) / Aukes, Daniel (Thesis advisor) / Sugar, Thomas (Committee member) / Zhang, Wenlong (Committee member) / Arizona State University (Publisher)
Created2021
161597-Thumbnail Image.png
Description
This work presents the design, modeling, analysis, and experimental characterization and testing of soft wearable robotics for lower limb rehabilitation for the ankle and hip. The Soft Robotic Ankle-Foot Orthosis (SR-AFO) is a wearable soft robot designed using multiple pneumatically-powered soft actuators to assist the ankle in multiple degrees-of-freedom during

This work presents the design, modeling, analysis, and experimental characterization and testing of soft wearable robotics for lower limb rehabilitation for the ankle and hip. The Soft Robotic Ankle-Foot Orthosis (SR-AFO) is a wearable soft robot designed using multiple pneumatically-powered soft actuators to assist the ankle in multiple degrees-of-freedom during standing and walking tasks. The flat fabric pneumatic artificial muscle (ff-PAM) contracts upon pressurization and assists ankle plantarflexion in the sagittal plane. The Multi-material Actuator for Variable Stiffness (MAVS) aids in supporting ankle inversion/eversion in the frontal plane. Analytical models of the ff-PAM and MAVS were created to understand how the changing of the design parameters affects tensile force generation and stiffness support, respectively. The models were validated by both finite element analysis and experimental characterization using a universal testing machine. A set of human experiments were performed with healthy participants: 1) to measure lateral ankle support during quiet standing, 2) to determine lateral ankle support during walking over compliant surfaces, and 3) to evaluate plantarflexion assistance at push-off during treadmill walking, and 4) determine if the SR-AFO could be used for gait entrainment. Group results revealed increased ankle stiffness during quiet standing with the MAVS active, reduced ankle deflection while walking over compliant surfaces with the MAVS active, and reduced muscle effort from the SOL and GAS during 40 - 60% of the gait cycle with the dual ff-PAM active. The SR-AFO shows promising results in providing lateral ankle support and plantarflexion assistance with healthy participants, and a drastically increased basin of entrainment, which suggests a capability to help restore the gait of impaired users in future trials. The ff-PAM actuators were used in an X-orientation to assist the hip in flexion and extension. The Soft Robotic Hip Exosuit (SR-HExo) was evaluated using the same set of actuators and trials with healthy participants showed reduction in muscle effort during hip flexion and extension to further enhance the study of soft fabric actuators on human gait assistance.
ContributorsThalman, Carly Megan (Author) / Lee, Hyunglae (Thesis advisor) / Artemiadis, Panagiotis (Thesis advisor) / Sugar, Thomas (Committee member) / Zhang, Wenlong (Committee member) / Arizona State University (Publisher)
Created2021
132015-Thumbnail Image.png
Description
The mean age of the world’s population is rapidly increasing and with that growth in an aging population a large number of elderly people are in need of walking assistance. In addition, a number of medical conditions contribute to gait disorders that require gait rehabilitation. Wearable robotics can be used

The mean age of the world’s population is rapidly increasing and with that growth in an aging population a large number of elderly people are in need of walking assistance. In addition, a number of medical conditions contribute to gait disorders that require gait rehabilitation. Wearable robotics can be used to improve functional outcomes in the gait rehabilitation process. The ankle push-off phase of an individual’s gait is vital to their ability to walk and propel themselves forward. During the ankle push-off phase of walking, plantar flexors are required to providing a large amount of force to power the heel off the ground.

The purpose of this project is to improve upon the passive ankle foot orthosis originally designed in the ASU’s Robotics and Intelligent Systems Laboratory (RISE Lab). This device utilizes springs positioned parallel to the user’s Achilles tendon which store energy to be released during the push off phase of the user’s gait cycle. Goals of the project are to improve the speed and reliability of the ratchet and pawl mechanism, design the device to fit a wider range of shoe sizes, and reduce the overall mass and size of the device. The resulting system is semi-passive and only utilizes a single solenoid to unlock the ratcheting mechanism when the spring’s potential force is required. The device created also utilizes constant force springs rather than traditional linear springs which allows for a more predictable level of force. A healthy user tested the device on a treadmill and surface electromyography (sEMG) sensors were placed on the user’s plantar flexor muscles to monitor potential reductions in muscular activity resulting from the assistance provided by the AFO device. The data demonstrates the robotic shoe was able to assist during the heel-off stage and reduced activation in the plantar flexor muscles was evident from the EMG data collected. As this is an ongoing research project, this thesis will also recommend possible design upgrades and changes to be made to the device in the future. These upgrades include utilizing a carbon fiber or lightweight plastic frame such as many of the traditional ankle foot-orthosis sold today and introducing a system to regulate the amount of spring force applied as a function of the force required at specific times of the heel off gait phase.
ContributorsSchaller, Marcus Frank (Author) / Zhang, Wenlong (Thesis director) / Sugar, Thomas (Committee member) / Engineering Programs (Contributor) / Barrett, The Honors College (Contributor)
Created2019-12