This collection includes both ASU Theses and Dissertations, submitted by graduate students, and the Barrett, Honors College theses submitted by undergraduate students. 

Displaying 1 - 10 of 148
152222-Thumbnail Image.png
Description
An embedded HVDC system is a dc link with at least two ends being physically connected within a single synchronous ac network. The thesis reviews previous works on embedded HVDC, proposes a dynamic embedded HVDC model by PSCAD program, and compares the transient stability performance among AC, DC and embedded

An embedded HVDC system is a dc link with at least two ends being physically connected within a single synchronous ac network. The thesis reviews previous works on embedded HVDC, proposes a dynamic embedded HVDC model by PSCAD program, and compares the transient stability performance among AC, DC and embedded HVDC. The test results indicate that by installing the embedded HVDC, AC network transient stability performance has been largely improved. Therefore the thesis designs a novel frequency control topology for embedded HVDC. According to the dynamic performance test results, when the embedded HVDC system equipped with a frequency control, the system transient stability will be improved further.
ContributorsYu, Jicheng (Author) / Karady, George G. (Thesis advisor) / Hui, Yu (Committee member) / Holbert, Keith E. (Committee member) / Arizona State University (Publisher)
Created2013
152174-Thumbnail Image.png
Description
Recent trends in the electric power industry have led to more attention to optimal operation of power transformers. In a deregulated environment, optimal operation means minimizing the maintenance and extending the life of this critical and costly equipment for the purpose of maximizing profits. Optimal utilization of a transformer can

Recent trends in the electric power industry have led to more attention to optimal operation of power transformers. In a deregulated environment, optimal operation means minimizing the maintenance and extending the life of this critical and costly equipment for the purpose of maximizing profits. Optimal utilization of a transformer can be achieved through the use of dynamic loading. A benefit of dynamic loading is that it allows better utilization of the transformer capacity, thus increasing the flexibility and reliability of the power system. This document presents the progress on a software application which can estimate the maximum time-varying loading capability of transformers. This information can be used to load devices closer to their limits without exceeding the manufacturer specified operating limits. The maximally efficient dynamic loading of transformers requires a model that can accurately predict both top-oil temperatures (TOTs) and hottest-spot temperatures (HSTs). In the previous work, two kinds of thermal TOT and HST models have been studied and used in the application: the IEEE TOT/HST models and the ASU TOT/HST models. And, several metrics have been applied to evaluate the model acceptability and determine the most appropriate models for using in the dynamic loading calculations. In this work, an investigation to improve the existing transformer thermal models performance is presented. Some factors that may affect the model performance such as improper fan status and the error caused by the poor performance of IEEE models are discussed. Additional methods to determine the reliability of transformer thermal models using metrics such as time constant and the model parameters are also provided. A new production grade application for real-time dynamic loading operating purpose is introduced. This application is developed by using an existing planning application, TTeMP, as a start point, which is designed for the dispatchers and load specialists. To overcome the limitations of TTeMP, the new application can perform dynamic loading under emergency conditions, such as loss-of transformer loading. It also has the capability to determine the emergency rating of the transformers for a real-time estimation.
ContributorsZhang, Ming (Author) / Tylavsky, Daniel J (Thesis advisor) / Ayyanar, Raja (Committee member) / Holbert, Keith E. (Committee member) / Arizona State University (Publisher)
Created2013
152258-Thumbnail Image.png
Description
Underground cables have been widely used in big cities. This is because underground cables offer the benefits of reducing visual impact and the disturbance caused by bad weather (wind, ice, snow, and the lightning strikes). Additionally, when placing power lines underground, the maintenance costs can also be reduced as a

Underground cables have been widely used in big cities. This is because underground cables offer the benefits of reducing visual impact and the disturbance caused by bad weather (wind, ice, snow, and the lightning strikes). Additionally, when placing power lines underground, the maintenance costs can also be reduced as a result. The underground cable rating calculation is the most critical part of designing the cable construction and cable installation. In this thesis, three contributions regarding the cable ampacity study have been made. First, an analytical method for rating of underground cables has been presented. Second, this research also develops the steady state and transient ratings for Salt River Project (SRP) 69 kV underground system using the commercial software CYMCAP for several typical substations. Third, to find an alternative way to predict the cable ratings, three regression models have been built. The residual plot and mean square error for the three methods have been analyzed. The conclusion is dawn that the nonlinear regression model provides the sufficient accuracy of the cable rating prediction for SRP's typical installation.
ContributorsWang, Tong (Author) / Tylavsky, Daniel (Thesis advisor) / Karady, George G. (Committee member) / Holbert, Keith E. (Committee member) / Arizona State University (Publisher)
Created2013
151785-Thumbnail Image.png
Description
This dissertation explores the role of smart home service provisions (SHSP) as motivational agents supporting goal attainment and human flourishing. Evoking human flourishing as a lens for interaction encapsulates issues of wellbeing, adaptation and problem solving within the context of social interaction. To investigate this line of research a new,

This dissertation explores the role of smart home service provisions (SHSP) as motivational agents supporting goal attainment and human flourishing. Evoking human flourishing as a lens for interaction encapsulates issues of wellbeing, adaptation and problem solving within the context of social interaction. To investigate this line of research a new, motivation-sensitive approach to design was implemented. This approach combined psychometric analysis from motivational psychology's Personal Project Analysis (PPA) and Place Attachment theory's Sense of Place (SoP) analysis to produce project-centered motivational models for environmental congruence. Regression analysis of surveys collected from 150 (n = 150) young adults about their homes revealed PPA motivational dimensions had significant main affects on all three SoP factors. Model one indicated PPA dimensions Fearful and Value Congruency predicted the SoP factor Place Attachment (p = 0.012). Model two indicated the PPA factor Positive Affect and PPA dimensions Value Congruency, Self Identity and Autonomy predicted Place Identity (p = .0003). Model three indicated PPA dimensions Difficulty and Likelihood of Success predicted the SoP factor Place Dependency. The relationships between motivational PPA dimensions and SoP demonstrated in these models informed creation of a set of motivational design heuristics. These heuristics guided 20 participants (n = 20) through co-design of paper prototypes of SHSPs supporting goal attainment and human flourishing. Normative analysis of these paper prototypes fashioned a design framework consisting of the use cases "make with me", "keep me on task" and "improve myself"; the four design principles "time and timing", "guidance and accountability", "project ambiguity" and "positivity mechanisms"; and the seven interaction models "structuring time", "prompt user", "gather resources", "consume content", "create content", "restrict and/or restore access to content" and "share content". This design framework described and evaluated three technology probes installed in the homes of three participants (n = 3) for field-testing over the course of one week. A priori and post priori samples of psychometric measures were inconclusive in determining if SHSP motivated goal attainment or increased environmental congruency between young adults and their homes.
ContributorsBrotman, Ryan Scott (Author) / Burleson, Winsow (Thesis advisor) / Heywood, William (Committee member) / Forlizzi, Jodi (Committee member) / Arizona State University (Publisher)
Created2013
151824-Thumbnail Image.png
Description
There is a lack of music therapy services for college students who have problems with depression and/or anxiety. Even among universities and colleges that offer music therapy degrees, there are no known programs offering music therapy to the institution's students. Female college students are particularly vulnerable to depression and anxiety

There is a lack of music therapy services for college students who have problems with depression and/or anxiety. Even among universities and colleges that offer music therapy degrees, there are no known programs offering music therapy to the institution's students. Female college students are particularly vulnerable to depression and anxiety symptoms compared to their male counterparts. Many students who experience mental health problems do not receive treatment, because of lack of knowledge, lack of services, or refusal of treatment. Music therapy is proposed as a reliable and valid complement or even an alternative to traditional counseling and pharmacotherapy because of the appeal of music to young women and the potential for a music therapy group to help isolated students form supportive networks. The present study recruited 14 female university students to participate in a randomized controlled trial of short-term group music therapy to address symptoms of depression and anxiety. The students were randomly divided into either the treatment group or the control group. Over 4 weeks, each group completed surveys related to depression and anxiety. Results indicate that the treatment group's depression and anxiety scores gradually decreased over the span of the treatment protocol. The control group showed either maintenance or slight worsening of depression and anxiety scores. Although none of the results were statistically significant, the general trend indicates that group music therapy was beneficial for the students. A qualitative analysis was also conducted for the treatment group. Common themes were financial concerns, relationship problems, loneliness, and time management/academic stress. All participants indicated that they benefited from the sessions. The group progressed in its cohesion and the participants bonded to the extent that they formed a supportive network which lasted beyond the end of the protocol. The results of this study are by no means conclusive, but do indicate that colleges with music therapy degree programs should consider adding music therapy services for their general student bodies.
ContributorsAshton, Barbara (Author) / Crowe, Barbara J. (Thesis advisor) / Rio, Robin (Committee member) / Davis, Mary (Committee member) / Arizona State University (Publisher)
Created2013
151352-Thumbnail Image.png
Description
A fully automated logic design methodology for radiation hardened by design (RHBD) high speed logic using fine grained triple modular redundancy (TMR) is presented. The hardening techniques used in the cell library are described and evaluated, with a focus on both layout techniques that mitigate total ionizing dose (TID) and

A fully automated logic design methodology for radiation hardened by design (RHBD) high speed logic using fine grained triple modular redundancy (TMR) is presented. The hardening techniques used in the cell library are described and evaluated, with a focus on both layout techniques that mitigate total ionizing dose (TID) and latchup issues and flip-flop designs that mitigate single event transient (SET) and single event upset (SEU) issues. The base TMR self-correcting master-slave flip-flop is described and compared to more traditional hardening techniques. Additional refinements are presented, including testability features that disable the self-correction to allow detection of manufacturing defects. The circuit approach is validated for hardness using both heavy ion and proton broad beam testing. For synthesis and auto place and route, the methodology and circuits leverage commercial logic design automation tools. These tools are glued together with custom CAD tools designed to enable easy conversion of standard single redundant hardware description language (HDL) files into hardened TMR circuitry. The flow allows hardening of any synthesizable logic at clock frequencies comparable to unhardened designs and supports standard low-power techniques, e.g. clock gating and supply voltage scaling.
ContributorsHindman, Nathan (Author) / Clark, Lawrence T (Thesis advisor) / Holbert, Keith E. (Committee member) / Barnaby, Hugh (Committee member) / Allee, David (Committee member) / Arizona State University (Publisher)
Created2012
151381-Thumbnail Image.png
Description
The dissolution of metal layers such as silver into chalcogenide glass layers such as germanium selenide changes the resistivity of the metal and chalcogenide films by a great extent. It is known that the incorporation of the metal can be achieved by ultra violet light exposure or thermal processes. In

The dissolution of metal layers such as silver into chalcogenide glass layers such as germanium selenide changes the resistivity of the metal and chalcogenide films by a great extent. It is known that the incorporation of the metal can be achieved by ultra violet light exposure or thermal processes. In this work, the use of metal dissolution by exposure to gamma radiation has been explored for radiation sensor applications. Test structures were designed and a process flow was developed for prototype sensor fabrication. The test structures were designed such that sensitivity to radiation could be studied. The focus is on the effect of gamma rays as well as ultra violet light on silver dissolution in germanium selenide (Ge30Se70) chalcogenide glass. Ultra violet radiation testing was used prior to gamma exposure to assess the basic mechanism. The test structures were electrically characterized prior to and post irradiation to assess resistance change due to metal dissolution. A change in resistance was observed post irradiation and was found to be dependent on the radiation dose. The structures were also characterized using atomic force microscopy and roughness measurements were made prior to and post irradiation. A change in roughness of the silver films on Ge30Se70 was observed following exposure. This indicated the loss of continuity of the film which causes the increase in silver film resistance following irradiation. Recovery of initial resistance in the structures was also observed after the radiation stress was removed. This recovery was explained with photo-stimulated deposition of silver from the chalcogenide at room temperature confirmed with the re-appearance of silver dendrites on the chalcogenide surface. The results demonstrate that it is possible to use the metal dissolution effect in radiation sensing applications.
ContributorsChandran, Ankitha (Author) / Kozicki, Michael N (Thesis advisor) / Holbert, Keith E. (Committee member) / Barnaby, Hugh (Committee member) / Arizona State University (Publisher)
Created2012
151561-Thumbnail Image.png
Description
This dissertation presents a new hybrid fault current limiter (FCL) topology that is primarily intended to protect single-phase power equipment. It can however be extended to protect three phase systems but would need three devices to protect each individual phase. In comparison against the existing fault current limiter technology, the

This dissertation presents a new hybrid fault current limiter (FCL) topology that is primarily intended to protect single-phase power equipment. It can however be extended to protect three phase systems but would need three devices to protect each individual phase. In comparison against the existing fault current limiter technology, the salient fea-tures of the proposed topology are: a) provides variable impedance that provides a 50% reduction in prospective fault current; b) near instantaneous response time which is with-in the first half cycle (1-4 ms); c) the use of semiconductor switches as the commutating switch which produces reduced leakage current, reduced losses, improved reliability, and a faster switch time (ns-µs); d) zero losses in steady-state operation; e) use of a Neodym-ium (NdFeB) permanent magnet as the limiting impedance which reduces size, cost, weight, eliminates DC biasing and cooling costs; f) use of Pulse Width Modulation (PWM) to control the magnitude of the fault current to a user's desired level. g) experi-mental test system is developed and tested to prove the concepts of the proposed FCL. This dissertation presents the proposed topology and its working principle backed up with numerical verifications, simulation results, and hardware implementation results. Conclu-sions and future work are also presented.
ContributorsPrigmore, Jay (Author) / Karady, George G. (Thesis advisor) / Ayyanar, Raja (Committee member) / Holbert, Keith E. (Committee member) / Hedman, Kory (Committee member) / Arizona State University (Publisher)
Created2013
151600-Thumbnail Image.png
Description
Research has shown that the ability to smell is the most direct sense an individual can experience. With every breath a person takes, the brain recognizes thousands of molecules and makes connections with our memories to determine their composition. With the amount of research looking into how and why we

Research has shown that the ability to smell is the most direct sense an individual can experience. With every breath a person takes, the brain recognizes thousands of molecules and makes connections with our memories to determine their composition. With the amount of research looking into how and why we smell, researchers still have little understanding of how the nose and brain process an aroma, and how emotional and physical behavior is impacted. This research focused on the affects smell has on a caregiver in a simulated Emergency Department setting located in the SimET of Banner Good Samaritan Medical Center in Phoenix, Arizona. The study asked each participant to care for a programmed mannequin, or "patient", while performing simple computer-based tasks, including memory and recall, multi-tasking, and mood-mapping to gauge physical and mental performance. Three different aromatic environments were then introduced through diffusion and indirect inhalation near the participants' task space: 1) a control (no smell), 2) an odor (simulated dirty feet), and 3) an aroma (one of four true essential oils plus a current odor-eliminating compound used in many U.S. Emergency Departments). This study was meant to produce a stressful environment by leading the caregiver to stay in constant movement throughout the study through timed tasks, uncooperative equipment, and a needy "patient". The goal of this research was to determine if smells, and of what form of pleasantness and repulsiveness, can have an effect on the physical and mental performance of emergency caregivers. Findings from this study indicated that the "odor eliminating" method currently used in typical Emergency Departments, coffee grounds, is more problematic than helpful, and the introduction of true essential oils may not only reduce stress, but increase efficiency and, in turn, job satisfaction.
ContributorsClark, Carina M (Author) / Bernardi, Jose (Thesis advisor) / Heywood, William (Committee member) / Watts, Richard (Committee member) / Rosso, Rachel (Committee member) / Arizona State University (Publisher)
Created2013
151481-Thumbnail Image.png
Description
A growing body of research shows that characteristics of the built environment in healthcare facilities impact patients' well-being. Research findings suggest that patients form judgments of perceived quality care based on environmental characteristics. Patient outcomes and ratings of quality of care are linked to the environments' ability to reduce patient

A growing body of research shows that characteristics of the built environment in healthcare facilities impact patients' well-being. Research findings suggest that patients form judgments of perceived quality care based on environmental characteristics. Patient outcomes and ratings of quality of care are linked to the environments' ability to reduce patient stress as well as influence perceptions of quality of care. Historically, this research has been focused in the hospital environment. The United States healthcare system heavily relies on hospitals to treat (rather than prevent) illness, leading to a high per capita healthcare expenditure. Currently, this healthcare system is shifting to rely heavily on ambulatory care settings and primary care providers to detect, prevent, and manage expensive medical conditions. The highest rates of preventable disease and the lowest rates of primary care usage are found in the young adult population (ages 18 to 24). More than any other patient population, this segment rates their satisfaction with healthcare significantly low. For this population education, early detection, and monitoring will be key for a primary care focused model to have the greatest impact on care and long-term savings. Strong patient-physician connections ensure the success of a primary care focused model. The physical environment has the opportunity to provide a message consistent with a physician's practice values and goals. Environmental cues in the waiting area have the potential to relay these messages to the patient prior to physician contact. Through an understanding and optimization of these cues patient perception of quality of care may be increased, thus improving the patient-physician relationship. This study provides insight on how to optimize environmental impact on the healthcare experience. This descriptive exploratory study utilized a non-verbal self-report instrument to collect demographic information and measure participant's responses to two panoramic photos of primary care provider waiting areas. Respondents were asked to identify physical elements in the photos that contributed to their perceptions of the quality of care to be expected. The sample population consisted of 33, 18 to 24 year-olds leaving a total of 234 emotional markers and comments. Qualitative and quantitative revealed three key themes of appeal, comfort, and regard. Physical elements, in the photos, related to the themes include: General areas that were important to the respondents were the seating and reception areas, as well as the overall appearance of the waiting area. Key elements identified to be significant characteristics influencing perceptions of quality of care are presented in this study.
ContributorsBadura, Kerri (Author) / Lamb, Gerri (Thesis advisor) / Heywood, William (Committee member) / Wolf, Peter (Committee member) / Arizona State University (Publisher)
Created2012