Theses and Dissertations
Displaying 1 - 2 of 2
Filtering by
- Creators: Cao, Linyu
- Creators: Gonzalez-Velo, Yago
Description
Over the past three decades, significant progress in the development of organic light-emitting diodes (OLEDs) has been achieved, enabling OLEDs to become a main component in state-of-the-art displays and next generation solid-state lighting. As this technology advances, it is highly desirable to further improve the device efficiency and operational stability to drive the success of OLEDs in future display and lighting applications. This dissertation aims at developing novel organic emitting materials covering visible and near-infrared (NIR) emissions for efficient and table OLEDs. Firstly, a series of tetradentate Pd(II) complexes, which have attractive phosphorescent aggregate emission performance especially at high brightness level in device settings, have been developed. The luminescent lifetime of Pd(II) complex aggregates was demonstrated to be shorter than 1 μs with a close-to-unity photoluminescence quantum yield. Moreover, a systematic study regarding structure-property relationship was conducted on four tetradentate Pd(II) complexes, i.e., Pd3O3, Pd3O8-P, Pd3O8-Py2, and Pd3O8-Py5, featuring aggregate emission. As a result, an extremely efficient and stable OLED device utilizing Pd3O8-Py5 was achieved. It demonstrated a peak external quantum efficiency (EQE) of 37.3% with a reduced efficiency roll-off retaining a high EQE of 32.5% at 10000 cd m-2, and an estimated LT95 lifetime (time to 95% of the initial luminance) of 48246 h at 1000 cd m-2. Secondly, there is an increasing demand for NIR OLEDs with emission spectra beyond 900 nm to expand their applications in biometric authentication, night vision display, and telecommunication, etc. A stable and efficient NIR Pt(II) porphyrin complex named PtTPTNP-F8 was developed, and exhibited an electroluminescent spectrum at 920 nm. By carefully choosing the host materials, an PtTPTNP-F8 based NIR OLED achieved a EQE of 1.9%. Furthermore, an PtTPTNP-F8 OLED fabricated in a stable device structure demonstrated extraordinary operational stability with LT99 of >1000 h at 20 mA cm-2. Lastly, a series of imidazole-based blue Pt(II) complexes were developed and studied. Results indicated that structural modification of ligand molecules effectively tuned the emission spectral wavelength and bandwidth. Two blue complexes, i.e., Pt2O2 P2M and Pt2O2-PPy5-M, emitting at 472 and 476 nm respectively, exhibited narrow-band emission spectra with a full width at half maximum of 16 nm.
ContributorsCao, Linyu (Author) / Li, Jian (Thesis advisor) / Adams, James (Committee member) / Alford, Terry (Committee member) / Arizona State University (Publisher)
Created2021
Description
Total dose sensing systems (or radiation detection systems) have many applications,
ranging from survey monitors used to supervise the generated radioactive waste at
nuclear power plants to personal dosimeters which measure the radiation dose
accumulated in individuals. This dissertation work will present two different types of
novel devices developed at Arizona State University for total dose sensing applications.
The first detector technology is a mechanically flexible metal-chalcogenide glass (ChG)
based system which is fabricated on low cost substrates and are intended as disposable
total dose sensors. Compared to existing commercial technologies, these thin film
radiation sensors are simpler in form and function, and cheaper to produce and operate.
The sensors measure dose through resistance change and are suitable for applications
such as reactor dosimetry, radiation chemistry, and clinical dosimetry. They are ideal for
wearable devices due to the lightweight construction, inherent robustness to resist
breaking when mechanically stressed, and ability to attach to non-flat objects. Moreover,
their performance can be easily controlled by tuning design variables and changing
incorporated materials. The second detector technology is a wireless dosimeter intended
for remote total dose sensing. They are based on a capacitively loaded folded patch
antenna resonating in the range of 3 GHz to 8 GHz for which the load capacitance varies
as a function of total dose. The dosimeter does not need power to operate thus enabling
its use and implementation in the field without requiring a battery for its read-out. As a
result, the dosimeter is suitable for applications such as unattended detection systems
destined for covert monitoring of merchandise crossing borders, where nuclear material
tracking is a concern. The sensitive element can be any device exhibiting a known
variation of capacitance with total ionizing dose. The sensitivity of the dosimeter is
related to the capacitance variation of the radiation sensitive device as well as the high
frequency system used for reading. Both technologies come with the advantage that they
are easy to manufacture with reasonably low cost and sensing can be readily read-out.
ranging from survey monitors used to supervise the generated radioactive waste at
nuclear power plants to personal dosimeters which measure the radiation dose
accumulated in individuals. This dissertation work will present two different types of
novel devices developed at Arizona State University for total dose sensing applications.
The first detector technology is a mechanically flexible metal-chalcogenide glass (ChG)
based system which is fabricated on low cost substrates and are intended as disposable
total dose sensors. Compared to existing commercial technologies, these thin film
radiation sensors are simpler in form and function, and cheaper to produce and operate.
The sensors measure dose through resistance change and are suitable for applications
such as reactor dosimetry, radiation chemistry, and clinical dosimetry. They are ideal for
wearable devices due to the lightweight construction, inherent robustness to resist
breaking when mechanically stressed, and ability to attach to non-flat objects. Moreover,
their performance can be easily controlled by tuning design variables and changing
incorporated materials. The second detector technology is a wireless dosimeter intended
for remote total dose sensing. They are based on a capacitively loaded folded patch
antenna resonating in the range of 3 GHz to 8 GHz for which the load capacitance varies
as a function of total dose. The dosimeter does not need power to operate thus enabling
its use and implementation in the field without requiring a battery for its read-out. As a
result, the dosimeter is suitable for applications such as unattended detection systems
destined for covert monitoring of merchandise crossing borders, where nuclear material
tracking is a concern. The sensitive element can be any device exhibiting a known
variation of capacitance with total ionizing dose. The sensitivity of the dosimeter is
related to the capacitance variation of the radiation sensitive device as well as the high
frequency system used for reading. Both technologies come with the advantage that they
are easy to manufacture with reasonably low cost and sensing can be readily read-out.
ContributorsMahmud, Adnan, Ph.D (Author) / Barnaby, Hugh J. (Thesis advisor) / Kozicki, Michael N (Committee member) / Gonzalez-Velo, Yago (Committee member) / Goryll, Michael (Committee member) / Alford, Terry (Committee member) / Arizona State University (Publisher)
Created2017