Theses and Dissertations
Displaying 1 - 3 of 3
Filtering by
- All Subjects: Ionizing radiation--Dosage.
Description
New technologies enable the exploration of space, high-fidelity defense systems, lighting fast intercontinental communication systems as well as medical technologies that extend and improve patient lives. The basis for these technologies is high reliability electronics devised to meet stringent design goals and to operate consistently for many years deployed in the field. An on-going concern for engineers is the consequences of ionizing radiation exposure, specifically total dose effects. For many of the different applications, there is a likelihood of exposure to radiation, which can result in device degradation and potentially failure. While the total dose effects and the resulting degradation are a well-studied field and methodologies to help mitigate degradation have been developed, there is still a need for simulation techniques to help designers understand total dose effects within their design. To that end, the work presented here details simulation techniques to analyze as well as predict the total dose response of a circuit. In this dissertation the total dose effects are broken into two sub-categories, intra-device and inter-device effects in CMOS technology. Intra-device effects degrade the performance of both n-channel and p-channel transistors, while inter-device effects result in loss of device isolation. In this work, multiple case studies are presented for which total dose degradation is of concern. Through the simulation techniques, the individual device and circuit responses are modeled post-irradiation. The use of these simulation techniques by circuit designers allow predictive simulation of total dose effects, allowing focused design changes to be implemented to increase radiation tolerance of high reliability electronics.
ContributorsSchlenvogt, Garrett (Author) / Barnaby, Hugh (Thesis advisor) / Goodnick, Stephen (Committee member) / Vasileska, Dragica (Committee member) / Holbert, Keith E. (Committee member) / Arizona State University (Publisher)
Created2014
Description
Total dose sensing systems (or radiation detection systems) have many applications,
ranging from survey monitors used to supervise the generated radioactive waste at
nuclear power plants to personal dosimeters which measure the radiation dose
accumulated in individuals. This dissertation work will present two different types of
novel devices developed at Arizona State University for total dose sensing applications.
The first detector technology is a mechanically flexible metal-chalcogenide glass (ChG)
based system which is fabricated on low cost substrates and are intended as disposable
total dose sensors. Compared to existing commercial technologies, these thin film
radiation sensors are simpler in form and function, and cheaper to produce and operate.
The sensors measure dose through resistance change and are suitable for applications
such as reactor dosimetry, radiation chemistry, and clinical dosimetry. They are ideal for
wearable devices due to the lightweight construction, inherent robustness to resist
breaking when mechanically stressed, and ability to attach to non-flat objects. Moreover,
their performance can be easily controlled by tuning design variables and changing
incorporated materials. The second detector technology is a wireless dosimeter intended
for remote total dose sensing. They are based on a capacitively loaded folded patch
antenna resonating in the range of 3 GHz to 8 GHz for which the load capacitance varies
as a function of total dose. The dosimeter does not need power to operate thus enabling
its use and implementation in the field without requiring a battery for its read-out. As a
result, the dosimeter is suitable for applications such as unattended detection systems
destined for covert monitoring of merchandise crossing borders, where nuclear material
tracking is a concern. The sensitive element can be any device exhibiting a known
variation of capacitance with total ionizing dose. The sensitivity of the dosimeter is
related to the capacitance variation of the radiation sensitive device as well as the high
frequency system used for reading. Both technologies come with the advantage that they
are easy to manufacture with reasonably low cost and sensing can be readily read-out.
ranging from survey monitors used to supervise the generated radioactive waste at
nuclear power plants to personal dosimeters which measure the radiation dose
accumulated in individuals. This dissertation work will present two different types of
novel devices developed at Arizona State University for total dose sensing applications.
The first detector technology is a mechanically flexible metal-chalcogenide glass (ChG)
based system which is fabricated on low cost substrates and are intended as disposable
total dose sensors. Compared to existing commercial technologies, these thin film
radiation sensors are simpler in form and function, and cheaper to produce and operate.
The sensors measure dose through resistance change and are suitable for applications
such as reactor dosimetry, radiation chemistry, and clinical dosimetry. They are ideal for
wearable devices due to the lightweight construction, inherent robustness to resist
breaking when mechanically stressed, and ability to attach to non-flat objects. Moreover,
their performance can be easily controlled by tuning design variables and changing
incorporated materials. The second detector technology is a wireless dosimeter intended
for remote total dose sensing. They are based on a capacitively loaded folded patch
antenna resonating in the range of 3 GHz to 8 GHz for which the load capacitance varies
as a function of total dose. The dosimeter does not need power to operate thus enabling
its use and implementation in the field without requiring a battery for its read-out. As a
result, the dosimeter is suitable for applications such as unattended detection systems
destined for covert monitoring of merchandise crossing borders, where nuclear material
tracking is a concern. The sensitive element can be any device exhibiting a known
variation of capacitance with total ionizing dose. The sensitivity of the dosimeter is
related to the capacitance variation of the radiation sensitive device as well as the high
frequency system used for reading. Both technologies come with the advantage that they
are easy to manufacture with reasonably low cost and sensing can be readily read-out.
ContributorsMahmud, Adnan, Ph.D (Author) / Barnaby, Hugh J. (Thesis advisor) / Kozicki, Michael N (Committee member) / Gonzalez-Velo, Yago (Committee member) / Goryll, Michael (Committee member) / Alford, Terry (Committee member) / Arizona State University (Publisher)
Created2017
Description
Implantable medical device technology is commonly used by doctors for disease management, aiding to improve patient quality of life. However, it is possible for these devices to be exposed to ionizing radiation during various medical therapeutic and diagnostic activities while implanted. This commands that these devices remain fully operational during, and long after, radiation exposure. Many implantable medical devices employ standard commercial complementary metal-oxide-semiconductor (CMOS) processes for integrated circuit (IC) development, which have been shown to degrade with radiation exposure. This necessitates that device manufacturers study the effects of ionizing radiation on their products, and work to mitigate those effects to maintain a high standard of reliability. Mitigation can be completed through targeted radiation hardening by design (RHBD) techniques as not to infringe on the device operational specifications. This thesis details a complete radiation analysis methodology that can be implemented to examine the effects of ionizing radiation on an IC as part of RHBD efforts. The methodology is put into practice to determine the failure mechanism in a charge pump circuit, common in many of today's implantable pacemaker designs, as a case study. Charge pump irradiation data shows a reduction of circuit output voltage with applied dose. Through testing of individual test devices, the response is identified as parasitic inter-device leakage caused by trapped oxide charge buildup in the isolation oxides. A library of compact models is generated to represent isolation oxide parasitics based on test structure data along with 2-Dimensional structure simulation results. The original charge pump schematic is then back-annotated with transistors representative of the parasitic. Inclusion of the parasitic devices in schematic allows for simulation of the entire circuit, accounting for possible parasitic devices activated by radiation exposure. By selecting a compact model for the parasitics generated at a specific dose, the compete circuit response is then simulated at the defined dose. The reduction of circuit output voltage with dose is then re-created in a radiation-enabled simulation validating the analysis methodology.
ContributorsSchlenvogt, Garrett (Author) / Barnaby, Hugh J (Thesis advisor) / Goodnick, Stephen (Committee member) / Vasileska, Dragica (Committee member) / Arizona State University (Publisher)
Created2010