This collection includes most of the ASU Theses and Dissertations from 2011 to present. ASU Theses and Dissertations are available in downloadable PDF format; however, a small percentage of items are under embargo. Information about the dissertations/theses includes degree information, committee members, an abstract, supporting data or media.
In addition to the electronic theses found in the ASU Digital Repository, ASU Theses and Dissertations can be found in the ASU Library Catalog.
Dissertations and Theses granted by Arizona State University are archived and made available through a joint effort of the ASU Graduate College and the ASU Libraries. For more information or questions about this collection contact or visit the Digital Repository ETD Library Guide or contact the ASU Graduate College at gradformat@asu.edu.
Traditionally, grid connected PV inverters required a transformer for isolation and safety. The disadvantage of high frequency transformer based inverters is complexity and cost. Transformerless inverters have become more popular recently, although they can be challenging to implement because of possible high frequency currents through the PV array's stay capacitance to earth ground. Conventional PV inverters also typically utilize electrolytic capacitors for bulk power buffering. However such capacitors can be prone to decreased reliability.
The solution proposed here to solve these problems is a bi directional buck boost converter combined with half bridge inverters. This configuration enables grounding of the array's negative terminal and passive power decoupling with only film capacitors.
Several aspects of the proposed converter are discussed. First a literature review is presented on the issues to be addressed. The proposed circuit is then presented and examined in detail. This includes theory of operation, component selection, and control systems. An efficiency analysis is also conducted. Simulation results are then presented that show correct functionality. A hardware prototype is built and experiment results also prove the concept. Finally some further developments are mentioned.
As a summary of the research a new topology and control technique were developed. The resultant circuit is a high performance transformerless PV inverter with upwards of 97% efficiency.
The goal of this study was to relate specific characteristics of team briefings back to objective measures of team performance. The study employed cognitive interviews, prospective observations, and principle component regression to characterize and model the relationship between team briefing characteristics and non-routine events (NREs) in gynecological surgery. Interviews were conducted with 13 team members representing each role on the surgical team and data were collected for 24 pre-operative team briefings and 45 subsequent surgical cases. The findings revealed that variations within the team briefing are associated with differences in team-related outcomes, namely NREs, during the subsequent surgical procedures. Synthesis of the data highlighted three important trends which include the need to promote team communication during the briefing, the importance of attendance by all surgical team members, and the value of holding a briefing prior to each surgical procedure. These findings have implications for development of formal briefing protocols.
Pre-operative team briefings are beneficial for team performance in the operating room. Future research will be needed to continue understanding this relationship between how briefings are conducted and team performance to establish more consistent approaches and as well as for the continuing assessment of team briefings and other similar team-related events in the operating room.
This document presents the research conducted to discriminate between reliable and unreliable models with the help of certain metrics. This was done by first eyeballing the prediction performance and then evaluating a number of mathematical metrics. Efforts were made to recognize the cause behind an unreliable model. Also research was conducted to improve the accuracy of the performance of the existing models.
A new application, described in this document, has been developed to automate the process of building thermal models for multiple transformers. These thermal models can then be used for transformer dynamic loading.