This repository houses peer-reviewed literature, data sets, reports, and other materials generated by researchers, practitioners, and other regional stakeholders that may be informative for local and regional efforts mitigating the adverse impacts of heat. The collection is intended to serve as a resource for anyone looking for information on top research findings, reports, or initiatives related to heat and air quality. This includes community, local, state, and regional partners and other interested parties contributing to heat and air quality planning, preparedness, and response activities.

More Information: The Phoenix Regional Heat and Air Quality Knowledge Repository is product of the Healthy Urban Environments (HUE) initiative in partnership with the Urban Climate Research Center. 

Displaying 1 - 2 of 2
Filtering by

Clear all filters

141437-Thumbnail Image.png
Description

Evaluation of built environment energy demand is necessary in light of global projections of urban expansion. Of particular concern are rapidly expanding urban areas in environments where consumption requirements for cooling are excessive. Here, we simulate urban air conditioning (AC) electric consumption for several extreme heat events during summertime over

Evaluation of built environment energy demand is necessary in light of global projections of urban expansion. Of particular concern are rapidly expanding urban areas in environments where consumption requirements for cooling are excessive. Here, we simulate urban air conditioning (AC) electric consumption for several extreme heat events during summertime over a semiarid metropolitan area with the Weather Research and Forecasting (WRF) model coupled to a multilayer building energy scheme. Observed total load values obtained from an electric utility company were split into two parts, one linked to meteorology (i.e., AC consumption) which was compared to WRF simulations, and another to human behavior. WRF-simulated non-dimensional AC consumption profiles compared favorably to diurnal observations in terms of both amplitude and timing. The hourly ratio of AC to total electricity consumption accounted for ~53% of diurnally averaged total electric demand, ranging from ~35% during early morning to ~65% during evening hours. Our work highlights the importance of modeling AC electricity consumption and its role for the sustainable planning of future urban energy needs. Finally, the methodology presented in this article establishes a new energy consumption-modeling framework that can be applied to any urban environment where the use of AC systems is prevalent.

ContributorsSalamanca, F. (Author) / Georgescu, Matei (Author) / Mahalov, A. (Author) / Moustaoui, M. (Author) / Wang, M. (Author) / Svoma, B. M. (Author)
Created2013-08-29
141441-Thumbnail Image.png
Description

Objectives: To provide novel quantification and advanced measurements of surface temperatures (Ts) in playgrounds, employing multiple scales of data, and provide insight into hot-hazard mitigation techniques and designs for improved environmental and public health.

Methods: We conduct an analysis of Ts in two Metro-Phoenix playgrounds at three scales: neighborhood (1 km

Objectives: To provide novel quantification and advanced measurements of surface temperatures (Ts) in playgrounds, employing multiple scales of data, and provide insight into hot-hazard mitigation techniques and designs for improved environmental and public health.

Methods: We conduct an analysis of Ts in two Metro-Phoenix playgrounds at three scales: neighborhood (1 km resolution), microscale (6.8 m resolution), and touch-scale (1 cm resolution). Data were derived from two sources: airborne remote sensing (neighborhood and microscale) and in situ (playground site) infrared Ts (touch-scale). Metrics of surface-to-air temperature deltas (Ts–a) and scale offsets (errors) are introduced.

Results: Select in situ Ts in direct sunlight are shown to approach or surpass values likely to result in burns to children at touch-scales much finer than Ts resolved by airborne remote sensing. Scale offsets based on neighbourhood and microscale ground observations are 3.8 ◦C and 7.3 ◦C less than the Ts–a at the 1 cm touch-scale, respectively, and 6.6 ◦C and 10.1 ◦C lower than touch-scale playground equipment Ts, respectively. Hence, the coarser scales underestimate high Ts within playgrounds. Both natural (tree) and artificial (shade sail) shade types are associated with significant reductions in Ts.

Conclusions: A scale mismatch exists based on differing methods of urban Ts measurement. The sub-meter touch-scale is the spatial scale at which data must be collected and policies of urban landscape design and health must be executed in order to mitigate high Ts in high-contact environments such as playgrounds. Shade implementation is the most promising mitigation technique to reduce child burns, increase park usability, and mitigate urban heating.

ContributorsVanos, Jennifer K. (Author) / Middel, Ariane (Author) / McKercher, Grant R. (Author) / Kuras, Evan R. (Author) / Ruddell, Benjamin L. (Author)
Created2015-11-10