Barrett, The Honors College at Arizona State University proudly showcases the work of undergraduate honors students by sharing this collection exclusively with the ASU community.

Barrett accepts high performing, academically engaged undergraduate students and works with them in collaboration with all of the other academic units at Arizona State University. All Barrett students complete a thesis or creative project which is an opportunity to explore an intellectual interest and produce an original piece of scholarly research. The thesis or creative project is supervised and defended in front of a faculty committee. Students are able to engage with professors who are nationally recognized in their fields and committed to working with honors students. Completing a Barrett thesis or creative project is an opportunity for undergraduate honors students to contribute to the ASU academic community in a meaningful way.

Displaying 1 - 10 of 11
Filtering by

Clear all filters

Description
Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain

Volume depletion can lead to migraines, dizziness, and significant decreases in a subject's ability to physically perform. A major cause of volume depletion is dehydration, or loss in fluids due to an imbalance in fluid intake to fluid excretion. Because proper levels of hydration are necessary in order to maintain both short and long term health, the ability to monitor hydration levels is growing in clinical demand. Although devices capable of monitoring hydration level exist, these devices are expensive, invasive, or inaccurate and do not offer a continuous mode of measurement. The ideal hydration monitor for consumer use needs to be characterized by its portability, affordability, and accuracy. Also, this device would need to be noninvasive and offer continuous hydration monitoring in order to accurately assess fluctuations in hydration data throughout a specified time period. One particular method for hydration monitoring that fits the majority of these criteria is known as bioelectric impedance analysis (BIA). Although current devices using BIA do not provide acceptable levels of accuracy, portability, or continuity in data collection, BIA could potentially be modified to fit many, if not all, desired customer specifications. The analysis presented here assesses the viability of using BIA as a new standard in hydration level measurement. The analysis uses data collected from 22 subjects using an existing device that employs BIA. A regression derived for estimating TBW based on the parameters of age, weight, height, sex, and impedance is presented. Using impedance data collected for each subject, a regression was also derived for estimating impedance based on the factors of age, weight, height, and sex. The derived regression was then used to calculate a new impedance value for each subject, and these new impedance values were used to estimate TBW. Through a paired-t test between the TBW values derived by using the direct measurements versus the calculated measurements of impedance, the two samples were found to be comparable. Considerations for BIA as a noninvasive measurement of hydration are discussed.
ContributorsTenorio, Jorge Antonio (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Spano, Mark (Committee member) / Barrett, The Honors College (Contributor) / W. P. Carey School of Business (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137549-Thumbnail Image.png
Description
Currently, the management of diabetes mellitus (DM) involves the monitoring of only blood glucose using self-monitoring blood glucose devices (SMBGs) followed by taking interventional steps, if needed. To increase the amount of information that diabetics can have to base DM care decisions off of, the development of an insulin biosensor

Currently, the management of diabetes mellitus (DM) involves the monitoring of only blood glucose using self-monitoring blood glucose devices (SMBGs) followed by taking interventional steps, if needed. To increase the amount of information that diabetics can have to base DM care decisions off of, the development of an insulin biosensor is explored. Such a biosensor incorporates electrochemical impedance spectroscopy (EIS) to ensure an extremely sensitive platform. Additionally, anti-insulin antibody was immobilized onto the surface of a gold disk working electrode to ensure a highly specific sensing platform as well. EIS measurements were completed with a 5mV sine wave that was swept through the frequency spectrum of 100 kHz to 1 Hz on concentrations of insulin ranging from 0 pM to 100 μM. The frequency at which the interaction between insulin and its antibody was optimized was determined by finding out at which frequency the R2 and slope of the impedance-concentration plot were best. This frequency, otherwise known as the optimal binding frequency, was determined to be 459 Hz. Three separate electrodes were developed and the impedance data for each concentration measured at 459 Hz was averaged and plotted against the LOG (pM insulin) to construct the calibration curve. The response was calculated to be 263.64 ohms/LOG(pM insulin) with an R2 value of 0.89. Additionally, the average RSD was determined to be 19.24% and the LLD was calculated to be 8.47 pM, which is well below the physiological normal range. These results highlight the potential success of developing commercial point-of-care insulin biosensors or multi-marker devices operating with integrated insulin detection.
ContributorsDecke, Zachary William (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Cook, Curtiss (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137550-Thumbnail Image.png
Description
This report provides information concerning qualities of methylcellulose and how those properties affect further experimentation within the biomedical world. Utilizing the compound’s biocompatibility many issues, ranging from surgical to cosmetic, can be solved. As of recent, studies indicate, methylcellulose has been used as a physically cross-linked gel, which

This report provides information concerning qualities of methylcellulose and how those properties affect further experimentation within the biomedical world. Utilizing the compound’s biocompatibility many issues, ranging from surgical to cosmetic, can be solved. As of recent, studies indicate, methylcellulose has been used as a physically cross-linked gel, which cannot sustain a solid form within the body. Therefore, this report will ultimately explore the means of creating a non-degradable, injectable, chemically cross-linking methylcellulose- based hydrogel. Methylcellulose will be evaluated and altered in experiments conducted within this report and a chemical cross-linker, developed from Jeffamine ED 2003 (O,O′-Bis(2-aminopropyl) polypropylene glycol-block-polyethylene glycol-block-polypropylene glycol), will be created. Experimentation with these elements is outlined here, and will ultimately prompt future revisions and analysis.
ContributorsBundalo, Zoran Luka (Author) / Vernon, Brent (Thesis director) / LaBelle, Jeffrey (Committee member) / Overstreet, Derek (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137439-Thumbnail Image.png
Description
Bangladesh is facing one of the largest mass poisonings in human history with over 77 million people affected by contaminated water each and every day. Over the last few years, the 33 Buckets team has come together to help fulfill this clean water need through filtration, education, and an innovative

Bangladesh is facing one of the largest mass poisonings in human history with over 77 million people affected by contaminated water each and every day. Over the last few years, the 33 Buckets team has come together to help fulfill this clean water need through filtration, education, and an innovative distribution system to inspire and empower people in Bangladesh and across the world. To start this process, we are working with the Rahima Hoque Girls' school in the rural area of Raipura, Bangladesh to give girls access to clean water where they spend the most time. Through our assessment trip in May 2012, we were able to acquire technical data, community input, and partnerships necessary to move our project forward. Additionally, we realized that in many cases, including the Rahima Hoque school, water problems are not caused by a lack of technology, but rather a lack of utilization and maintenance long-term. To remedy this, 33 Buckets has identified a local filter to have installed at the school, and has designed a small-scale business focused on selling clean water in bulk to the surrounding community. Our price point and association with the Rahima Hoque Girls' school makes our solution sustainable. Plus, with the success of our first site, we see the potential to scale. We already have five nearby schools interested in working to implement similar water projects, and with over 100,000 schools in Bangladesh, many of which lack access to the right water systems, we have a huge opportunity to impact millions of lives. This thesis project describes our journey through this process. First, an introduction to our work prior to the assessment trip and through the ASU EPICS program is given. Second, we include quantitative and qualitative details regarding our May 2012 assessment trip to the Rahima Hoque school and Dhaka. Third, we recount some of the experiences we were able to participate in following the trip to Bangladesh, including the Dell Social Innovation Challenge. Fourth, we examine the technical filtration methods, business model development, and educational materials that will be used to implement our solution this summer. Finally, we include an Appendix with a variety of social venture competitions and applications that we have submitted over the past two years, in addition to other supplementary materials. These are excellent examples of our diligence and provide unique insight into the growth of our project.
ContributorsStrong, Paul Andrew (Co-author) / Shah, Pankti (Co-author) / Huerta, Mark (Co-author) / Henderson, Mark (Thesis director) / El Asmar, Mounir (Committee member) / LaBelle, Jeffrey (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2013-05
137648-Thumbnail Image.png
Description
Camp Hope is an organization dedicated to motivating children in foster care to pursue higher education. In this paper, the organization's founder applies the engineering design process to the problems currently facing Arizona's foster care system. What emerges is Camp Hope (i.e. the "product") and in turn a model by

Camp Hope is an organization dedicated to motivating children in foster care to pursue higher education. In this paper, the organization's founder applies the engineering design process to the problems currently facing Arizona's foster care system. What emerges is Camp Hope (i.e. the "product") and in turn a model by which it can be promulgated throughout the Phoenix metropolitan area and abroad. Prototype camps held abroad in Mexico, and at local group homes in Tempe, Arizona verify the initial user inputs with 68% of campers reporting new academic interests in pre/post camp surveys. Future work includes continued fine-tuning of the model through continued Arizona camps, and longer-term surveys tracking the development of children who participate in the program.
ContributorsSaez, Neil Alexander (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Fitzgerald, Charles A. (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137680-Thumbnail Image.png
Description
Intracranial aneurysms, which form in the blood vessels of the brain, are particularly dangerous because of the importance and fragility of the human brain. When an intracranial aneurysm gets large it poses a significant risk of bursting and causing subarachnoid hemorrhaging (SAH), a possibly fatal condition. One possible treatment involves

Intracranial aneurysms, which form in the blood vessels of the brain, are particularly dangerous because of the importance and fragility of the human brain. When an intracranial aneurysm gets large it poses a significant risk of bursting and causing subarachnoid hemorrhaging (SAH), a possibly fatal condition. One possible treatment involves placing a stent in the vessel to act as a flow diverter. In this study we look at the hemodynamics of two geometries of idealized basilar tip aneurysms, at 2,3, and 4 ml/s pulsatile flow, at three different points in the cardiac cycle. The smaller model had neck and dome diameters of 2.67 mm and 4 mm respectively, while the larger aneurysm had neck and dome diameters of 3 mm and 6 mm respectively. Both diameters and the dome to neck ratio increased in the second model, representing growth over time. Flow was analyzed using stereoscopic particle image velocimetry (PIV) for both geometries in untreated models, as well as after treatment with a high porosity Enterprise stent (Codman and Shurtleff Inc.). Flow in the models was characterized by root mean square velocity in the aneurysm and neck plane, cross neck flow, max aneurysm vorticity, and total aneurysm kinetic energy. It was found that in the smaller aneurysm model (model 1), Enterprise stent treatment reduced all flow parameters substantially. The smallest reduction was in max vorticity, at 42.48%, and the largest in total kinetic energy, at 75.69%. In the larger model (model 2) there was a 52.18% reduction in cross neck flow, but a 167.28% increase in aneurysm vorticity. The other three parameters experienced little change. These results, along with observed velocity vector fields, indicate a noticeable diversion of flow away from the aneurysm in the stent treated model 1. Treatment in model 2 had a small flow diversion effect, but also altered flow in unpredictable ways, in some cases having a detrimental effect on aneurysm hemodynamics. The results of this study indicate that Enterprise stent treatment is only effective in small, relatively undeveloped aneurysm geometries, and waiting until an aneurysm has grown too large can eliminate this treatment option altogether.
ContributorsLindsay, James Bryan (Author) / Frakes, David (Thesis director) / LaBelle, Jeffrey (Committee member) / Nair, Priya (Committee member) / Barrett, The Honors College (Contributor) / School of Humanities, Arts, and Cultural Studies (Contributor)
Created2013-05
Description
The purpose of this thesis was to explore how changes in the geometry of a bifurcating cerebral aneurysm will affect the hemodynamics in idealized models after stent treatment. This thesis explores the use of a computationally modeled Enterprise Vascular Reconstruction Device (Cordis, East Bridgewater, NJ), a high porosity and closed

The purpose of this thesis was to explore how changes in the geometry of a bifurcating cerebral aneurysm will affect the hemodynamics in idealized models after stent treatment. This thesis explores the use of a computationally modeled Enterprise Vascular Reconstruction Device (Cordis, East Bridgewater, NJ), a high porosity and closed cell design. The models represent idealized cases of saccular aneurysms with dome sizes of either 4mm or 6mm and a dome to neck ratio of either 3:2 or 2:1. Two aneurysm contact angles are studied, one at 45 degrees and the other at 90 degrees. The stent was characterized and deployed with the use of Finite Element Analysis into each model. Computational Fluid Dynamic principles were applied in series of simulations on treated and untreated models. Data was gathered in the neck plane for the average velocity magnitude, root mean squared velocity, average flow vector angle of deflection, and the cross neck flow rate. Within the aneurysm, the average velocity magnitude, root mean squared velocity, and average pressure were calculated. Additionally, the mass flow rate at each outlet was recorded. The results of this study indicate that the Enterprise Stent was most effective in the sharper, 90 degree geometry of Model 3. Additionally, the stent had an adverse effect on the Models 1 and 4, which had the smallest neck sizes. Conclusions are that the Enterprise Stent, as a stand-alone treatment method is only reliable in situations that take advantage of its design.
ContributorsThomas, Kyle Andrew (Author) / Frakes, David (Thesis director) / LaBelle, Jeffrey (Committee member) / Babiker, Haithem (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
137769-Thumbnail Image.png
Description
Electrochemical sensors function by detecting electroactive species at the electrode surface of a screen printed sensor. As more force is applied, the concentration of electroactive species at the surface of the sensor increases and a larger current is measured. Thus, when all conditions including voltage are made constant, as in

Electrochemical sensors function by detecting electroactive species at the electrode surface of a screen printed sensor. As more force is applied, the concentration of electroactive species at the surface of the sensor increases and a larger current is measured. Thus, when all conditions including voltage are made constant, as in Amp i-t, a quantifiable current can be read and the force applied can be calculated. Two common electrochemical techniques in which current is measured, cyclic voltammetry(CV) and amperometric i-t(Amp i-t), were used. A compressible sensor capable of transducing a force and acquiring feedback was created.
ContributorsFeldman, Austin Marc (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Santello, Marco (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05
Description
This report outlines the current methods and instrumentation used for diabetes monitoring and detection, and evaluates the problems that these methods face. Additionally, it will present an approach to remedy these problems. The purpose of this project is to create a potentiostat that is capable of controlling a diabetes meter

This report outlines the current methods and instrumentation used for diabetes monitoring and detection, and evaluates the problems that these methods face. Additionally, it will present an approach to remedy these problems. The purpose of this project is to create a potentiostat that is capable of controlling a diabetes meter that monitors multiple biological markers simultaneously. Glucose is the most commonly measured biomarker for diabetes. However, it provides only a limited amount of information. In order to give the user of the meter more information about the progression of his or her disease, the concentrations of several different biological markers for diabetes may be measured using a system that operates in a similar fashion to blood glucose meters. The potentiostat provides an input voltage into the electrode sensor and receives the current from the sensor as the output. From this information, the impedance may be calculated. The concentrations of each of the biomarkers in the blood sample can then be determined. In an effort to increase sensitivity, the diabetes meter forgoes the use of amperometric i-t in favor of the electrochemical impedance spectroscopy technique. A three-electrode electrochemical sensor is used with the meter. In order to perform simultaneous and rapid testing of biomarker concentration, a single multisine input wave is generated using a hardware implementation of a summing amplifier and waveform generators.
ContributorsWu, Diane Zhang (Author) / LaBelle, Jeffrey (Thesis director) / Bakkaloglu, Bertan (Committee member) / Spano, Mark (Committee member) / Barrett, The Honors College (Contributor) / Electrical Engineering Program (Contributor)
Created2013-05
137782-Thumbnail Image.png
Description
Development of a rapid and label-free Electrochemical Impedance Spectroscopy (EIS) biosensor for Cardiovascular Disease (CVD) detection based on Inerluekin-18 (IL-18) sensitivity was proposed to fill the technology gap between rapid and portable CVD point-of-care diagnosis. IL-18 was chosen for this CVD biosensor due to its ability to detect plaque vulnerability

Development of a rapid and label-free Electrochemical Impedance Spectroscopy (EIS) biosensor for Cardiovascular Disease (CVD) detection based on Inerluekin-18 (IL-18) sensitivity was proposed to fill the technology gap between rapid and portable CVD point-of-care diagnosis. IL-18 was chosen for this CVD biosensor due to its ability to detect plaque vulnerability of the heart. Custom (hand) made sensors, which utilized a three electrode configuration with a gold disk working electrode, were created to run EIS using both IL-18 and anti-IL-18 molecules in both purified and blood solutions. The EIS results for IL-18 indicated the optimal detection frequency to be 371Hz. Blood interaction on the working electrode increased the dynamic range of impedance values for the biosensor. Future work includes Developing and testing prototypes of the biosensor along with determining if a Nafion based coating on the working electrode will reduce the dynamic range of impedance values caused by blood interference.
ContributorsJha, Amit (Author) / LaBelle, Jeffrey (Thesis director) / Mossman, Kenneth (Committee member) / Frakes, David (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor) / Department of Management (Contributor)
Created2013-05