The title “Regents’ Professor” is the highest faculty honor awarded at Arizona State University. It is conferred on ASU faculty who have made pioneering contributions in their areas of expertise, who have achieved a sustained level of distinction, and who enjoy national and international recognition for these accomplishments. This collection contains primarily open access works by ASU Regents' Professors.

Displaying 1 - 5 of 5
Filtering by

Clear all filters

130268-Thumbnail Image.png
Description
Purpose: To evaluate a new method of measuring ocular exposure in the context of a natural blink pattern through analysis of the variables tear film breakup time (TFBUT), interblink interval (IBI), and tear film breakup area (BUA).
Methods: The traditional methodology (Forced-Stare [FS]) measures TFBUT and IBI separately. TFBUT is measured

Purpose: To evaluate a new method of measuring ocular exposure in the context of a natural blink pattern through analysis of the variables tear film breakup time (TFBUT), interblink interval (IBI), and tear film breakup area (BUA).
Methods: The traditional methodology (Forced-Stare [FS]) measures TFBUT and IBI separately. TFBUT is measured under forced-stare conditions by an examiner using a stopwatch, while IBI is measured as the subject watches television. The new methodology (video capture manual analysis [VCMA]) involves retrospective analysis of video data of fluorescein-stained eyes taken through a slit lamp while the subject watches television, and provides TFBUT and BUA for each IBI during the 1-minute video under natural blink conditions. The FS and VCMA methods were directly compared in the same set of dry-eye subjects. The VCMA method was evaluated for the ability to discriminate between dry-eye subjects and normal subjects. The VCMA method was further evaluated in the dry eye subjects for the ability to detect a treatment effect before, and 10 minutes after, bilateral instillation of an artificial tear solution.
Results: Ten normal subjects and 17 dry-eye subjects were studied. In the dry-eye subjects, the two methods differed with respect to mean TFBUTs (5.82 seconds, FS; 3.98 seconds, VCMA; P = 0.002). The FS variables alone (TFBUT, IBI) were not able to successfully distinguish between the dry-eye and normal subjects, whereas the additional VCMA variables, both derived and observed (BUA, BUA/IBI, breakup rate), were able to successfully distinguish between the dry-eye and normal subjects in a statistically significant fashion. TFBUT (P = 0.034) and BUA/IBI (P = 0.001) were able to distinguish the treatment effect of artificial tears in dry-eye subjects.
Conclusion: The VCMA methodology provides a clinically relevant analysis of tear film stability measured in the context of a natural blink pattern.
Created2011-09-21
130267-Thumbnail Image.png
Description
Purpose: To investigate use of an improved ocular tear film analysis protocol (OPI 2.0) in the Controlled Adverse Environment (CAE[superscript SM]) model of dry eye disease, and to examine the utility of new metrics in the identification of subpopulations of dry eye patients.
Methods: Thirty-three dry eye subjects completed a single-center,

Purpose: To investigate use of an improved ocular tear film analysis protocol (OPI 2.0) in the Controlled Adverse Environment (CAE[superscript SM]) model of dry eye disease, and to examine the utility of new metrics in the identification of subpopulations of dry eye patients.
Methods: Thirty-three dry eye subjects completed a single-center, single-visit, pilot CAE study. The primary endpoint was mean break-up area (MBA) as assessed by the OPI 2.0 system. Secondary endpoints included corneal fluorescein staining, tear film break-up time, and OPI 2.0 system measurements. Subjects were also asked to rate their ocular discomfort throughout the CAE. Dry eye endpoints were measured at baseline, immediately following a 90-minute CAE exposure, and again 30 minutes after exposure.
Results: The post-CAE measurements of MBA showed a statistically significant decrease from the baseline measurements. The decrease was relatively specific to those patients with moderate to severe dry eye, as measured by baseline MBA. Secondary endpoints including palpebral fissure size, corneal staining, and redness, also showed significant changes when pre- and post-CAE measurements were compared. A correlation analysis identified specific associations between MBA, blink rate, and palpebral fissure size. Comparison of MBA responses allowed us to identify subpopulations of subjects who exhibited different compensatory mechanisms in response to CAE challenge. Of note, none of the measures of tear film break-up time showed statistically significant changes or correlations in pre-, versus post-CAE measures.
Conclusion: This pilot study confirms that the tear film metric MBA can detect changes in the ocular surface induced by a CAE, and that these changes are correlated with other, established measures of dry eye disease. The observed decrease in MBA following CAE exposure demonstrates that compensatory mechanisms are initiated during the CAE exposure, and that this compensation may provide the means to identify and characterize clinically relevant subpopulations of dry eye patients.
Created2012-11-12
130428-Thumbnail Image.png
Description
The impact of increasing penetration of converter control-based generators (CCBGs) in a large-scale power system is assessed through a model based small signal stability analysis. Three test bed cases for the years 2010, 2020, and 2022 of the Western Electricity Coordinating Council (WECC) in the United States are used for

The impact of increasing penetration of converter control-based generators (CCBGs) in a large-scale power system is assessed through a model based small signal stability analysis. Three test bed cases for the years 2010, 2020, and 2022 of the Western Electricity Coordinating Council (WECC) in the United States are used for the analysis. Increasing penetration of wind-based Type 3 and wind-based Type 4 and PV Solar CCBGs is used in the tests. The participation and interaction of CCBGs and synchronous generators in traditional electromechanical interarea modes is analyzed. Two new types of modes dominated by CCBGs are identified. The characteristics of these new modes are described and compared to electromechanical modes in the frequency domain. An examination of the mechanism of the interaction between the CCBG control states and the synchronous generator control states is presented and validated through dynamic simulations. Actual system and forecast load data are used throughout.
Created2014-09-01
130417-Thumbnail Image.png
Description
The increase of transmission line thermal ratings by reconductoring with high temperature low sag conductors is a comparatively new technology introduced for transmission expansion. A special design permits high temperature low sag conductors to operate at higher temperatures, therefore allowing passage of higher current and, thus, increasing the thermal rating

The increase of transmission line thermal ratings by reconductoring with high temperature low sag conductors is a comparatively new technology introduced for transmission expansion. A special design permits high temperature low sag conductors to operate at higher temperatures, therefore allowing passage of higher current and, thus, increasing the thermal rating of the transmission line. The comparatively high cost of high temperature low sag conductors may be an obstacle to its large-scale implementation. This article evaluates the expenditures for transmission line reconductoring using high temperature low sag, the consequent benefits obtained from the potential decrease in operating cost for thermally limited power transmission systems. Estimates of the “payback period” are used to evaluate the cost effectiveness of reconductoring with high temperature low sag. The evaluation is performed using a 225 bus equivalent of the 2012 summer peak Arizona portion of the Western Electricity Coordinating Council. The method is offered for transmission expansion analysis in which an economic benefit is calculated to assist in the transmission expansion decision.
Created2015-02-07
130416-Thumbnail Image.png
Description
High phase order systems have been proposed at the early inception of power transmission engineering, but few direct applications have been made. High phase order transmission should be considered as an alternative in the case of high power density applications. In this article, an analysis of transposition of high phase

High phase order systems have been proposed at the early inception of power transmission engineering, but few direct applications have been made. High phase order transmission should be considered as an alternative in the case of high power density applications. In this article, an analysis of transposition of high phase order overhead transmission lines is presented and voltage unbalance in high phase order systems is considered. Definitions are presented for “fully transposed” and “roll transposed” along with advantages and disadvantages of each. A generalized voltage unbalance factor is introduced and utilized to determine the benefits of transposition. The generalized voltage unbalance factor is compared with three other possible unbalance factors to determine if the generalized voltage unbalance factor is an appropriate indication of unbalance. Exemplary results are presented for 6-phase and 12-phase designs. Conclusions show that the generalized voltage unbalance factor is a good indication of transmission line voltage unbalance and certain configurations may not need full rotation transposition to minimize the unbalance factor. The transposition analysis and voltage unbalance are considerations in the assessment of high phase order as a high power transmission alternative.
Created2014-11-18