The title “Regents’ Professor” is the highest faculty honor awarded at Arizona State University. It is conferred on ASU faculty who have made pioneering contributions in their areas of expertise, who have achieved a sustained level of distinction, and who enjoy national and international recognition for these accomplishments. This collection contains primarily open access works by ASU Regents' Professors.
Filtering by
- Creators: Boutet, Sebastien
- Creators: Buman, Matthew
The aim of this study was to investigate the potential associations of reallocating 30 minutes sedentary time in long bouts (>60 min) to sedentary time in non-bouts, light intensity physical activity (LPA) and moderate- to vigorous physical activity (MVPA) with cardiometabolic risk factors in a population diagnosed with prediabetes or type 2 diabetes.
Methods
Participants diagnosed with prediabetes and type 2 diabetes (n = 124, 50% men, mean [SD] age = 63.8 [7.5] years) were recruited to the physical activity intervention Sophia Step Study. For this study baseline data was used with a cross-sectional design. Time spent in sedentary behaviors in bouts (>60 min) and non-bouts (accrued in <60 min bouts) and physical activity was measured using the ActiGraph GT1M. Associations of reallocating bouted sedentary time to non-bouted sedentary time, LPA and MVPA with cardiometabolic risk factors were examined using an isotemporal substitution framework with linear regression models.
Results
Reallocating 30 minutes sedentary time in bouts to MVPA was associated with lower waist circumference (b = -4.30 95% CI:-7.23, -1.38 cm), lower BMI (b = -1.46 95% CI:-2.60, -0.33 kg/m2) and higher HDL cholesterol levels (b = 0.11 95% CI: 0.02, 0.21 kg/m[superscript 2]. Similar associations were seen for reallocation of sedentary time in non-bouts to MVPA. Reallocating sedentary time in bouts to LPA was associated only with lower waist circumference.
Conclusion
Reallocation of sedentary time in bouts as well as non-bouts to MVPA, but not to LPA, was beneficially associated with waist circumference, BMI and HDL cholesterol in individuals with prediabetes and type 2 diabetes. The results of this study confirm the importance of reallocation sedentary time to MVPA.
Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a well-characterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 μm diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 Ångström were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.
X-ray free-electron lasers provide novel opportunities to conduct single particle analysis on nanoscale particles. Coherent diffractive imaging experiments were performed at the Linac Coherent Light Source (LCLS), SLAC National Laboratory, exposing single inorganic core-shell nanoparticles to femtosecond hard-X-ray pulses. Each facetted nanoparticle consisted of a crystalline gold core and a differently shaped palladium shell. Scattered intensities were observed up to about 7 nm resolution. Analysis of the scattering patterns revealed the size distribution of the samples, which is consistent with that obtained from direct real-space imaging by electron microscopy. Scattering patterns resulting from single particles were selected and compiled into a dataset which can be valuable for algorithm developments in single particle scattering research.
Serial femtosecond crystallography requires reliable and efficient delivery of fresh crystals across the beam of an X-ray free-electron laser over the course of an experiment. We introduce a double-flow focusing nozzle to meet this challenge, with significantly reduced sample consumption, while improving jet stability over previous generations of nozzles. We demonstrate its use to determine the first room-temperature structure of RNA polymerase II at high resolution, revealing new structural details. Moreover, the double flow-focusing nozzles were successfully tested with three other protein samples and the first room temperature structure of an extradiol ring-cleaving dioxygenase was solved by utilizing the improved operation and characteristics of these devices.