The title “Regents’ Professor” is the highest faculty honor awarded at Arizona State University. It is conferred on ASU faculty who have made pioneering contributions in their areas of expertise, who have achieved a sustained level of distinction, and who enjoy national and international recognition for these accomplishments. This collection contains primarily open access works by ASU Regents' Professors.
Filtering by
- Creators: Aquila, Andrew
- Creators: Buman, Matthew
The aim of this study was to investigate the potential associations of reallocating 30 minutes sedentary time in long bouts (>60 min) to sedentary time in non-bouts, light intensity physical activity (LPA) and moderate- to vigorous physical activity (MVPA) with cardiometabolic risk factors in a population diagnosed with prediabetes or type 2 diabetes.
Methods
Participants diagnosed with prediabetes and type 2 diabetes (n = 124, 50% men, mean [SD] age = 63.8 [7.5] years) were recruited to the physical activity intervention Sophia Step Study. For this study baseline data was used with a cross-sectional design. Time spent in sedentary behaviors in bouts (>60 min) and non-bouts (accrued in <60 min bouts) and physical activity was measured using the ActiGraph GT1M. Associations of reallocating bouted sedentary time to non-bouted sedentary time, LPA and MVPA with cardiometabolic risk factors were examined using an isotemporal substitution framework with linear regression models.
Results
Reallocating 30 minutes sedentary time in bouts to MVPA was associated with lower waist circumference (b = -4.30 95% CI:-7.23, -1.38 cm), lower BMI (b = -1.46 95% CI:-2.60, -0.33 kg/m2) and higher HDL cholesterol levels (b = 0.11 95% CI: 0.02, 0.21 kg/m[superscript 2]. Similar associations were seen for reallocation of sedentary time in non-bouts to MVPA. Reallocating sedentary time in bouts to LPA was associated only with lower waist circumference.
Conclusion
Reallocation of sedentary time in bouts as well as non-bouts to MVPA, but not to LPA, was beneficially associated with waist circumference, BMI and HDL cholesterol in individuals with prediabetes and type 2 diabetes. The results of this study confirm the importance of reallocation sedentary time to MVPA.
Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a well-characterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 μm diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 Ångström were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.
Serial femtosecond crystallography requires reliable and efficient delivery of fresh crystals across the beam of an X-ray free-electron laser over the course of an experiment. We introduce a double-flow focusing nozzle to meet this challenge, with significantly reduced sample consumption, while improving jet stability over previous generations of nozzles. We demonstrate its use to determine the first room-temperature structure of RNA polymerase II at high resolution, revealing new structural details. Moreover, the double flow-focusing nozzles were successfully tested with three other protein samples and the first room temperature structure of an extradiol ring-cleaving dioxygenase was solved by utilizing the improved operation and characteristics of these devices.
The purpose of this study is to determine the feasibility of three widely used wearable sensors in research settings for 24 h monitoring of sleep, sedentary, and active behaviors in middle-aged women.
Methods
Participants were 21 inactive, overweight (M Body Mass Index (BMI) = 29.27 ± 7.43) women, 30 to 64 years (M = 45.31 ± 9.67). Women were instructed to wear each sensor on the non-dominant hip (ActiGraph GT3X+), wrist (GENEActiv), or upper arm (BodyMedia SenseWear Mini) for 24 h/day and record daily wake and bed times for one week over the course of three consecutive weeks. Women received feedback about their daily physical activity and sleep behaviors. Feasibility (i.e., acceptability and demand) was measured using surveys, interviews, and wear time.
Results
Women felt the GENEActiv (94.7 %) and SenseWear Mini (90.0 %) were easier to wear and preferred the placement (68.4, 80 % respectively) as compared to the ActiGraph (42.9, 47.6 % respectively). Mean wear time on valid days was similar across sensors (ActiGraph: M = 918.8 ± 115.0 min; GENEActiv: M = 949.3 ± 86.6; SenseWear: M = 928.0 ± 101.8) and well above other studies using wake time only protocols. Informational feedback was the biggest motivator, while appearance, comfort, and inconvenience were the biggest barriers to wearing sensors. Wear time was valid on 93.9 % (ActiGraph), 100 % (GENEActiv), and 95.2 % (SenseWear) of eligible days. 61.9, 95.2, and 71.4 % of participants had seven valid days of data for the ActiGraph, GENEActiv, and SenseWear, respectively.
Conclusion
Twenty-four hour monitoring over seven consecutive days is a feasible approach in middle-aged women. Researchers should consider participant acceptability and demand, in addition to validity and reliability, when choosing a wearable sensor. More research is needed across populations and study designs.