This growing collection consists of scholarly works authored by ASU-affiliated faculty, staff, and community members, and it contains many open access articles. ASU-affiliated authors are encouraged to Share Your Work in KEEP.

Displaying 11 - 16 of 16
Filtering by

Clear all filters

129185-Thumbnail Image.png
Description

In this work, a selective solar absorber made of nanostructured titanium gratings deposited on an ultrathin MgF2 spacer and a tungsten ground film is proposed and experimentally demonstrated. Normal absorptance of the fabricated solar absorber is characterized to be higher than 0.9 in the UV, visible and, near infrared (IR)

In this work, a selective solar absorber made of nanostructured titanium gratings deposited on an ultrathin MgF2 spacer and a tungsten ground film is proposed and experimentally demonstrated. Normal absorptance of the fabricated solar absorber is characterized to be higher than 0.9 in the UV, visible and, near infrared (IR) regime, while the mid-IR emittance is around 0.2. The high broadband absorption in the solar spectrum is realized by the excitation of surface plasmon and magnetic polariton resonances, while the low mid-IR emittance is due to the highly reflective nature of the metallic components. Further directional and polarized reflectance measurements show wide-angle and polarization-insensitive high absorption within solar spectrum. Temperature-dependent spectroscopic characterization indicates that the optical properties barely change at elevated temperatures up to 350 °C. The solar-to-heat conversion efficiency with the fabricated metamaterial solar absorber is predicted to be 78% at 100 °C without optical concentration or 80% at 400 °C with 25 suns. The performance could be further improved with better fabrication processes and geometric optimization during metamaterial design. The strong spectral selectivity, favorable diffuse-like behavior, and good thermal stability make the metamaterial selective absorber promising for significantly enhancing solar thermal energy harvesting in various systems at mid to high temperatures.

ContributorsWang, Hao (Author) / Sivan, Vijay Prasad (Author) / Mitchell, Arnan (Author) / Rosengarten, Gary (Author) / Phelan, Patrick (Author) / Wang, Liping (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2015-06-01
129169-Thumbnail Image.png
Description

In this work, we numerically demonstrate an infrared (IR) frequency-tunable selective thermal emitter made of graphene-covered silicon carbide (SiC) gratings. Rigorous coupled-wave analysis shows temporally-coherent emission peaks associated with magnetic polariton (MP), whose resonance frequency can be dynamically tuned within the phonon absorption band of SiC by varying graphene chemical

In this work, we numerically demonstrate an infrared (IR) frequency-tunable selective thermal emitter made of graphene-covered silicon carbide (SiC) gratings. Rigorous coupled-wave analysis shows temporally-coherent emission peaks associated with magnetic polariton (MP), whose resonance frequency can be dynamically tuned within the phonon absorption band of SiC by varying graphene chemical potential. An analytical inductor–capacitor circuit model is introduced to quantitatively predict the resonance frequency and further elucidate the mechanism for the tunable emission peak. The effects of grating geometric parameters, such as grating height, groove width and grating period, on the selective emission peak are explored. The direction-independent behavior of MP and associated coherent emission are also demonstrated. Moreover, by depositing four layers of graphene sheets onto the SiC gratings, a large tunability of 8.5% in peak frequency can be obtained to yield the coherent emission covering a broad frequency range from 820 to 890 cm-1. The novel tunable metamaterial could pave the way to a new class of tunable thermal sources in the IR region.

ContributorsWang, Hao (Author) / Yang, Yue (Author) / Wang, Liping (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2015-04-01
127977-Thumbnail Image.png
Description

Background: To identify social ecological correlates of objectively measured workplace sedentary behavior.

Methods: Participants from 24 worksites - across academic, industrial, and government sectors - wore an activPAL-micro accelerometer for 7-days (Jan-Nov 2016). Work time was segmented using daily logs. Sedentary behavior outcomes included time spent sitting, standing, in light intensity physical activity

Background: To identify social ecological correlates of objectively measured workplace sedentary behavior.

Methods: Participants from 24 worksites - across academic, industrial, and government sectors - wore an activPAL-micro accelerometer for 7-days (Jan-Nov 2016). Work time was segmented using daily logs. Sedentary behavior outcomes included time spent sitting, standing, in light intensity physical activity (LPA, stepping cadence <100 steps/min), and in prolonged sitting bouts (>30 min). Outcomes were standardized to an 8 h work day. Two electronic surveys were completed to derive individual (job type and work engagement), cultural (lunch away from the desk, walking at lunch and face-to-face interaction), physical (personal printer and office type) and organizational (sector) factors. Mixed-model analyses with worksite-level clustering were performed to examine multi-level associations. Secondary analyses examined job type and sector as moderators of these associations. All models were adjusted for age, race/ethnicity and gender.

Results: Participants (N = 478; 72% female; age: 45.0 ± 11.3 years; 77.8% non-Hispanic white) wore the activPAL-micro for 90.2 ± 15.5% of the reported workday. Walking at lunch was positively associated with LPA (5.0 ± 0.5 min/8 h, P < 0.001). Regular face-to-face interaction was negatively associated with prolonged sitting (−11.3 ± 4.8 min/8 h, P < 0.05). Individuals in private offices sat more (20.1 ± 9.1 min/8 h, P < 0.05), stood less (−21.5 ± 8.8 min/8 h, P < 0.05), and engaged in more prolonged sitting (40.9 ± 11.2 min/8 h, P < 0.001) than those in public office space. These associations were further modified by job type and sector.

Conclusions: Work-specific individual, cultural, physical and organizational factors are associated with workplace sedentary behavior. Associations vary by job type and sector and should be considered in the design of workplace interventions to reduce sedentary behavior.

ContributorsMullane, Sarah (Author) / Toledo, Meynard John (Author) / Rydell, Sarah A. (Author) / Feltes, Linda H. (Author) / Vuong, Brenna (Author) / Crespo, Noe C. (Author) / Pereira, Mark A. (Author) / Buman, Matthew (Author) / College of Health Solutions (Contributor)
Created2017-08-31
127974-Thumbnail Image.png
Description

We numerically demonstrate a switchable metamaterial absorber/emitter by thermally turning on or off the excitation of magnetic resonance upon the phase transition of vanadium dioxide (VO2). Perfect absorption peak exists around the wavelength of 5 lm when the excitation of magnetic resonance is supported with the insulating VO2 spacer layer.

We numerically demonstrate a switchable metamaterial absorber/emitter by thermally turning on or off the excitation of magnetic resonance upon the phase transition of vanadium dioxide (VO2). Perfect absorption peak exists around the wavelength of 5 lm when the excitation of magnetic resonance is supported with the insulating VO2 spacer layer. The wavelength-selective absorption is switched off when the magnetic resonance is disabled with metallic VO2 that shorts the top and bottom metallic structures. The resonance wavelength can be tuned with different geometry, and the switchable metamaterial exhibits diffuse behaviors at oblique angles. The results would facilitate the design of switchable metamaterials for active control in energy and sensing applications.

ContributorsWang, Hao (Author) / Wang, Yue (Author) / Wang, Liping (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2014-08-19
128081-Thumbnail Image.png
Description

Background: Although current technological advancements have allowed for objective measurements of sedentary behavior via accelerometers, these devices do not provide the contextual information needed to identify targets for behavioral interventions and generate public health guidelines to reduce sedentary behavior. Thus, self-reports still remain an important method of measurement for physical

Background: Although current technological advancements have allowed for objective measurements of sedentary behavior via accelerometers, these devices do not provide the contextual information needed to identify targets for behavioral interventions and generate public health guidelines to reduce sedentary behavior. Thus, self-reports still remain an important method of measurement for physical activity and sedentary behaviors.

Objective: This study evaluated the reliability, validity, and sensitivity to change of a smartphone app in assessing sitting, light-intensity physical activity (LPA), and moderate-vigorous physical activity (MVPA).
Methods: Adults (N=28; 49.0 years old, standard deviation [SD] 8.9; 85% men; 73% Caucasian; body mass index=35.0, SD 8.3 kg/m2) reported their sitting, LPA, and MVPA over an 11-week behavioral intervention. During three separate 7-day periods, participants wore the activPAL3c accelerometer/inclinometer as a criterion measure. Intraclass correlation (ICC; 95% CI) and bias estimates (mean difference [δ] and root of mean square error [RMSE]) were used to compare app-based reported behaviors to measured sitting time (lying/seated position), LPA (standing or stepping at <100 steps/minute), and MVPA (stepping at >100 steps/minute).

Results: Test-retest results suggested moderate agreement with the criterion for sedentary time, LPA, and MVPA (ICC=0.65 [0.43-0.82], 0.67 [0.44-0.83] and 0.69 [0.48-0.84], respectively). The agreement between the two measures was poor (ICC=0.05-0.40). The app underestimated sedentary time (δ=-45.9 [-67.6, -24.2] minutes/day, RMSE=201.6) and overestimated LPA and MVPA (δ=18.8 [-1.30 to 38.9] minutes/day, RMSE=183; and δ=29.3 [25.3 to 33.2] minutes/day, RMSE=71.6, respectively). The app underestimated change in time spent during LPA and MVPA but overestimated change in sedentary time. Both measures showed similar directions in changed scores on sedentary time and LPA.

Conclusions: Despite its inaccuracy, the app may be useful as a self-monitoring tool in the context of a behavioral intervention. Future research may help to clarify reasons for under- or over-reporting of behaviors.

ContributorsToledo, Meynard John (Author) / Hekler, Eric (Author) / Hollingshead, Kevin (Author) / Epstein, Dana (Author) / Buman, Matthew (Author) / College of Health Solutions (Contributor)
Created2017-08
128035-Thumbnail Image.png
Description

Recently, near-field thermal radiation has attracted much attention in several fields since it can exceed the Planck blackbody limit through the coupling of evanescent waves. In this work, near-field radiative heat transfer between two semi-infinite dual uniaxial electromagnetic metamaterials with two different material property sets is theoretically analyzed. The near-field

Recently, near-field thermal radiation has attracted much attention in several fields since it can exceed the Planck blackbody limit through the coupling of evanescent waves. In this work, near-field radiative heat transfer between two semi-infinite dual uniaxial electromagnetic metamaterials with two different material property sets is theoretically analyzed. The near-field radiative heat transfer is calculated using fluctuational electrodynamics incorporated with anisotropic wave optics. The underlying mechanisms, namely, magnetic hyperbolic mode, magnetic surface polariton, electrical hyperbolic mode, and electrical surface polariton, between two homogeneous dual uniaxial electromagnetic metamaterials are investigated by examining the transmission coefficient and the spectral heat flux. The effect of vacuum gap distance is also studied, which shows that the enhancement at smaller vacuum gap is mainly due to hyperbolic mode and surface plasmon polariton modes. In addition, the results show that the contribution of s-polarized waves is significant and should not be excluded due to the strong magnetic response regardless of vacuum gap distances. The fundamental understanding and insights obtained here will facilitate the finding and application of novel materials for near-field thermal radiation.

ContributorsChang, Jui-Yung (Author) / Basu, Soumyadipta (Author) / Yang, Yue (Author) / Wang, Liping (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2016-06-07