Matching Items (4)
150896-Thumbnail Image.png
Description
Human operators have difficulty driving cranes quickly, accurately, and safely because of the slow response of heavy crane structures, non-intuitive control interfaces, and payload oscillations. Recently, a novel hand-motion crane control system has been proposed to improve performance by coupling an intuitive control interface with an element that reduces the

Human operators have difficulty driving cranes quickly, accurately, and safely because of the slow response of heavy crane structures, non-intuitive control interfaces, and payload oscillations. Recently, a novel hand-motion crane control system has been proposed to improve performance by coupling an intuitive control interface with an element that reduces the complex oscillatory behavior of the payload. Hand-motion control allows operators to drive a crane by simply moving a hand-held radio-frequency tag through the desired path. Real-time location sensors are used to track the movements of the tag and the tag position is used in a feedback control loop to drive the crane. An input shaper is added to eliminate dangerous payload oscillations. However, tag position measurements are corrupted by noise. It is important to understand the noise properties so that appropriate filters can be designed to mitigate the effects of noise and improve tracking accuracy. This work discusses implementing filtering techniques to address the issue of noise in the operating environment. Five different filters are used on experimentally-acquired tag trajectories to reduce noise. The filtered trajectories are then used to drive crane simulations. Filter performance is evaluated with respect to the energy usage of the crane trolley, the settling time of the crane payload oscillations, and the safety corridor of the crane trajectory. The effects of filter window lengths on these parameters are also investigated. An adaptive filtering technique, namely the Kalman filter, adapts to the noise characteristics of the workspace to minimize the tag tracking error and performs better than the other filtering techniques examined.
ContributorsRagunathan, Sudarshan (Author) / Frakes, David (Thesis advisor) / Singhose, William (Committee member) / Tillery, Stephen Helms (Committee member) / Arizona State University (Publisher)
Created2012
153632-Thumbnail Image.png
Description
Intracranial pressure is an important parameter to monitor, and elevated intracranial pressure can be life threatening. Elevated intracranial pressure is indicative of distress in the brain attributed by conditions such as aneurysm, traumatic brain injury, brain tumor, hydrocephalus, stroke, or meningitis.

Electrocorticography (ECoG) recordings are invaluable in understanding epilepsy and

Intracranial pressure is an important parameter to monitor, and elevated intracranial pressure can be life threatening. Elevated intracranial pressure is indicative of distress in the brain attributed by conditions such as aneurysm, traumatic brain injury, brain tumor, hydrocephalus, stroke, or meningitis.

Electrocorticography (ECoG) recordings are invaluable in understanding epilepsy and detecting seizure zones. However, ECoG electrodes cause a foreign body mass effect, swelling, and pneumocephaly, which results in elevation of intracranial pressure (ICP). Thus, the aim of this work is to design an intracranial pressure monitoring system that could augment ECoG electrodes.

A minimally invasive, low-cost epidural intracranial pressure monitoring system is developed for this purpose, using a commercial pressure transducer available for biomedical applications. The system is composed of a pressure transducer, sensing cup, electronics, and data acquisition system. The pressure transducer is a microelectromechanical system (MEMS)-based die that works on piezoresistive phenomenon with dielectric isolation for direct contact with fluids.

The developed system was bench tested and verified in an animal model to confirm the efficacy of the system for intracranial pressure monitoring. The system has a 0.1 mmHg accuracy and a 2% error for the 0-10 mmHg range, with resolution of 0.01 mmHg. This system serves as a minimally invasive (2 mm burr hole) epidural ICP monitor, which could augment existing ECoG electrode arrays, to simultaneously measure intracranial pressure along with the neural signals.

This device could also be employed with brain implants that causes elevation in ICP due to tissue - implant interaction often leading to edema. This research explores the concept and feasibility for integrating the sensing component directly on to the ECoG electrode arrays.
ContributorsSampath Kumaran, Ranjani (Author) / Christen, Jennifer Blain (Thesis advisor) / Tillery, Stephen Helms (Committee member) / Greger, Bradley (Committee member) / Arizona State University (Publisher)
Created2015
Description
Understanding human-human interactions during the performance of joint motor tasks is critical for developing rehabilitation robots that could aid therapists in providing effective treatments for motor problems. However, there is a lack of understanding of strategies (cooperative or competitive) adopted by humans when interacting with other individuals. Previous studies have

Understanding human-human interactions during the performance of joint motor tasks is critical for developing rehabilitation robots that could aid therapists in providing effective treatments for motor problems. However, there is a lack of understanding of strategies (cooperative or competitive) adopted by humans when interacting with other individuals. Previous studies have investigated the cues (auditory, visual and haptic) that support these interactions but understanding how these unconscious interactions happen even without those cues is yet to be explained. To address this issue, in this study, a paradigm that tests the parallel efforts of pairs of individuals (dyads) to complete a jointly performed virtual reaching task, without any auditory or visual information exchange was employed. Motion was tracked with a NDI OptoTrak 3D motion tracking system that captured each subject’s movement kinematics, through which we could measure the level of synchronization between two subjects in space and time. For the spatial analyses, the movement amplitudes and direction errors at peak velocities and at endpoints were analyzed. Significant differences in the movement amplitudes were found for subjects in 4 out of 6 dyads which were expected due to the lack of feedback between the subjects. Interestingly, subjects in this study also planned their movements in different directions in order to counteract the visuomotor rotation offered in the test blocks, which suggests the difference in strategies for the subjects in each dyad. Also, the level of de-adaptation in the control blocks in which no visuomotor rotation was offered to the subjects was measured. To further validate the results obtained through spatial analyses, a temporal analyses was done in which the movement times for the two subjects were compared. With the help of these results, numerous interaction scenarios that are possible in the human joint actions in without feedback were analyzed.
ContributorsAgrawal, Ankit (Author) / Buneo, Christopher (Thesis advisor) / Santello, Marco (Committee member) / Tillery, Stephen Helms (Committee member) / Arizona State University (Publisher)
Created2016
158637-Thumbnail Image.png
Description
The ability to inhibit a planned but inappropriate response, and switch to executing a goal-relevant motor response, is critically important for the regulation of motor behaviors. Inhibition and switching could be mediated by various control mechanisms. Proactive control uses contextual information (cues) to plan the response for the target stimulus

The ability to inhibit a planned but inappropriate response, and switch to executing a goal-relevant motor response, is critically important for the regulation of motor behaviors. Inhibition and switching could be mediated by various control mechanisms. Proactive control uses contextual information (cues) to plan the response for the target stimulus (probe) based on the expectation of a response inhibition or switching stimulus combination. Previous work has reported the involvement of several brain areas associated with proactive inhibition and switching, e.g., dorsolateral prefrontal cortex, anterior cingulate cortex, inferior frontal junction, and pre-supplementary motor area. However, how these areas interact and their functional role in different types of cognitive control is still debated. An AX-version of the continuous performance task (AX-CPT) was used to examine proactive inhibition and switching of motor actions. In a typical AX-CPT trial, a contextual cue stimulus is presented, followed by a probe stimulus after a specific inter-stimulus interval. As part of a trial sequence, if a target cue and target probe are presented, a target response is to be provided when the probe is observed. Otherwise, a non-target response is to be provided for all other stimuli. A behavioral switching AX-CPT experiment (48 subjects) was conducted to explore the parameters that induce a proactive shift in the motor response. Participants who performed the AX-CPT task with relatively shorter interstimulus interval predominantly and consistently exhibited proactive control behavior. A follow-up pilot study (3 subjects) of response inhibition versus response switching AX-CPT was performed using 256-channel high-density electroencephalography (HD-EEG). HD-EEG was used to identify the time course of cortical activation in brain areas associated with response inhibition. It was observed that one out of three participants used a proactive strategy for response switching based on probe response error and probe response reaction time. Instantaneous amplitude spatial maps obtained from HD-EEG revealed cortical activity corresponding to conflict between proactively-prepared incorrect responses and reactively-corrected goal-relevant responses after the probe was presented.
ContributorsMysore, Archana Shashidhar (Author) / Santello, Marco (Thesis advisor) / Blais, Christopher (Committee member) / Brewer, Gene (Committee member) / Tillery, Stephen Helms (Committee member) / Arizona State University (Publisher)
Created2020