Matching Items (2)
172014-Thumbnail Image.png
Description
A well-insulated dark conventional rooftop can be hotter than any other urban surface, including pavements. Since rooftops cover around 20 – 25% of most urban areas, their role in the urban heat island effect is significant. In general, buildings exchange heat with the surroundings in three ways: heat release from

A well-insulated dark conventional rooftop can be hotter than any other urban surface, including pavements. Since rooftops cover around 20 – 25% of most urban areas, their role in the urban heat island effect is significant. In general, buildings exchange heat with the surroundings in three ways: heat release from the cooling/heating system, air exchange associated with exfiltration and relief air, and heat transfer between the building envelope and surroundings. Several recent studies show that the building envelope generates more heat release into the environment than any other building component.Current advancements in material science have enabled the development of materials and coatings with very high solar reflectance and thermal emissivity, and that can alter their radiative properties based on surface temperature. This dissertation is an effort to quantify the impact of recent developments in such technologies on urban air. The current study addresses three specific unresolved topics: 1) the relative importance of rooftop solar reflectance and thermal emissivity, 2) the role of rooftop radiative properties in different climates, and 3) the impact of temperature-adaptive exterior materials/coatings on building energy savings and urban cooling. The findings from this study show that the use of rooftop materials with solar reflectance above 0.9 maintain the surface temperature below ambient air temperature most of the time, even when the materials have conventional thermal emissivity (0.9). This research has demonstrated that for hot cities, rooftops with high solar reflectance and thermal emittance maximize building energy savings and always cool the surrounding air. For moderate climate regions, high solar reflectance and low thermal emittance result in the greatest building energy cost savings. This combination of radiative properties cools the air during the daytime and warms it at night. Finally, this research found that temperature-adaptive materials could play a significant role in reducing utility costs for poorly insulated buildings, but that they heat the surrounding air in the winter, irrespective of the rooftop insulation. Through the detailed analysis of building façade radiative properties, this dissertation offers climate-specific design guidance that can be used to simultaneously optimize energy costs while minimizing adverse warming of the surrounding environment.
ContributorsPrem Anand Jayaprabha, Jyothis Anand (Author) / Sailor, David (Thesis advisor) / Phelan, Patrick (Thesis advisor) / Huang, Huei-Ping (Committee member) / Wang, Liping (Committee member) / Yeom, Dongwoo Jason (Committee member) / Arizona State University (Publisher)
Created2022
156208-Thumbnail Image.png
Description
In recent years, 40% of the total world energy consumption and greenhouse gas emissions is because of buildings. Out of that 60% of building energy consumption is due to HVAC systems. Under current trends these values will increase in coming years. So, it is important to identify passive cooling or

In recent years, 40% of the total world energy consumption and greenhouse gas emissions is because of buildings. Out of that 60% of building energy consumption is due to HVAC systems. Under current trends these values will increase in coming years. So, it is important to identify passive cooling or heating technologies to meet this need. The concept of thermal energy storage (TES), as noted by many authors, is a promising way to rectify indoor temperature fluctuations. Due to its high energy density and the use of latent energy, Phase Change Materials (PCMs) are an efficient choice to use as TES. A question that has not satisfactorily been addressed, however, is the optimum location of PCM. In other words, given a constant PCM mass, where is the best location for it in a building? This thesis addresses this question by positioning PCM to obtain maximum energy savings and peak time delay. This study is divided into three parts. The first part is to understand the thermal behavior of building surfaces, using EnergyPlus software. For analysis, a commercial prototype building model for a small office in Phoenix, provided by the U.S. Department of Energy, is applied and the weather location file for Phoenix, Arizona is also used. The second part is to justify the best location, which is obtained from EnergyPlus, using a transient grey box building model. For that we have developed a Resistance-Capacitance (RC) thermal network and studied the thermal profile of a building in Phoenix. The final part is to find the best location for PCMs in buildings using EnergyPlus software. In this part, the mass of PCM used in each location remains unchanged. This part also includes the impact of the PCM mass on the optimized location and how the peak shift varies. From the analysis, it is observed that the ceiling is the best location to install PCM for yielding the maximum reduction in HVAC energy consumption for a hot, arid climate like Phoenix.
ContributorsPrem Anand Jayaprabha, Jyothis Anand (Author) / Phelan, Patrick (Thesis advisor) / Wang, Robert (Committee member) / Parrish, Kristen (Committee member) / Arizona State University (Publisher)
Created2018