Matching Items (2)
155110-Thumbnail Image.png
Description
Accurate quantitative information of tumor/lesion volume plays a critical role

in diagnosis and treatment assessment. The current clinical practice emphasizes on efficiency, but sacrifices accuracy (bias and precision). In the other hand, many computational algorithms focus on improving the accuracy, but are often time consuming and cumbersome to use. Not to

Accurate quantitative information of tumor/lesion volume plays a critical role

in diagnosis and treatment assessment. The current clinical practice emphasizes on efficiency, but sacrifices accuracy (bias and precision). In the other hand, many computational algorithms focus on improving the accuracy, but are often time consuming and cumbersome to use. Not to mention that most of them lack validation studies on real clinical data. All of these hinder the translation of these advanced methods from benchside to bedside.

In this dissertation, I present a user interactive image application to rapidly extract accurate quantitative information of abnormalities (tumor/lesion) from multi-spectral medical images, such as measuring brain tumor volume from MRI. This is enabled by a GPU level set method, an intelligent algorithm to learn image features from user inputs, and a simple and intuitive graphical user interface with 2D/3D visualization. In addition, a comprehensive workflow is presented to validate image quantitative methods for clinical studies.

This application has been evaluated and validated in multiple cases, including quantifying healthy brain white matter volume from MRI and brain lesion volume from CT or MRI. The evaluation studies show that this application has been able to achieve comparable results to the state-of-the-art computer algorithms. More importantly, the retrospective validation study on measuring intracerebral hemorrhage volume from CT scans demonstrates that not only the measurement attributes are superior to the current practice method in terms of bias and precision but also it is achieved without a significant delay in acquisition time. In other words, it could be useful to the clinical trials and clinical practice, especially when intervention and prognostication rely upon accurate baseline lesion volume or upon detecting change in serial lesion volumetric measurements. Obviously, this application is useful to biomedical research areas which desire an accurate quantitative information of anatomies from medical images. In addition, the morphological information is retained also. This is useful to researches which require an accurate delineation of anatomic structures, such as surgery simulation and planning.
ContributorsXue, Wenzhe (Author) / Kaufman, David (Thesis advisor) / Mitchell, J. Ross (Thesis advisor) / Johnson, William (Committee member) / Scotch, Matthew (Committee member) / Arizona State University (Publisher)
Created2016
128818-Thumbnail Image.png
Description

Background: Genetic profiling represents the future of neuro-oncology but suffers from inadequate biopsies in heterogeneous tumors like Glioblastoma (GBM). Contrast-enhanced MRI (CE-MRI) targets enhancing core (ENH) but yields adequate tumor in only ~60% of cases. Further, CE-MRI poorly localizes infiltrative tumor within surrounding non-enhancing parenchyma, or brain-around-tumor (BAT), despite the importance

Background: Genetic profiling represents the future of neuro-oncology but suffers from inadequate biopsies in heterogeneous tumors like Glioblastoma (GBM). Contrast-enhanced MRI (CE-MRI) targets enhancing core (ENH) but yields adequate tumor in only ~60% of cases. Further, CE-MRI poorly localizes infiltrative tumor within surrounding non-enhancing parenchyma, or brain-around-tumor (BAT), despite the importance of characterizing this tumor segment, which universally recurs. In this study, we use multiple texture analysis and machine learning (ML) algorithms to analyze multi-parametric MRI, and produce new images indicating tumor-rich targets in GBM.

Methods: We recruited primary GBM patients undergoing image-guided biopsies and acquired pre-operative MRI: CE-MRI, Dynamic-Susceptibility-weighted-Contrast-enhanced-MRI, and Diffusion Tensor Imaging. Following image coregistration and region of interest placement at biopsy locations, we compared MRI metrics and regional texture with histologic diagnoses of high- vs low-tumor content (≥80% vs <80% tumor nuclei) for corresponding samples. In a training set, we used three texture analysis algorithms and three ML methods to identify MRI-texture features that optimized model accuracy to distinguish tumor content. We confirmed model accuracy in a separate validation set.

Results: We collected 82 biopsies from 18 GBMs throughout ENH and BAT. The MRI-based model achieved 85% cross-validated accuracy to diagnose high- vs low-tumor in the training set (60 biopsies, 11 patients). The model achieved 81.8% accuracy in the validation set (22 biopsies, 7 patients).

Conclusion: Multi-parametric MRI and texture analysis can help characterize and visualize GBM’s spatial histologic heterogeneity to identify regional tumor-rich biopsy targets.

ContributorsHu, Leland S. (Author) / Ning, Shuluo (Author) / Eschbacher, Jennifer M. (Author) / Gaw, Nathan (Author) / Dueck, Amylou C. (Author) / Smith, Kris A. (Author) / Nakaji, Peter (Author) / Plasencia, Jonathan (Author) / Ranjbar, Sara (Author) / Price, Stephen J. (Author) / Tran, Nhan (Author) / Loftus, Joseph (Author) / Jenkins, Robert (Author) / O'Neill, Brian P. (Author) / Elmquist, William (Author) / Baxter, Leslie C. (Author) / Gao, Fei (Author) / Frakes, David (Author) / Karis, John P. (Author) / Zwart, Christine (Author) / Swanson, Kristin R. (Author) / Sarkaria, Jann (Author) / Wu, Teresa (Author) / Mitchell, J. Ross (Author) / Li, Jing (Author) / Ira A. Fulton Schools of Engineering (Contributor)
Created2015-11-24