This study investigated the difference in biofilm growth between pristine polypropylene microplastics and aged polypropylene microplastics. The microplastics were added to Tempe Town Lake water for 4 weeks. Each week the microplastic biofilms were quantified. Comparing the total biofilm counts, the results showed that the aged microplastic biofilms were larger than the pristine each week. By week 3 the aged microplastic counts had almost doubled in size increasing from 324 to 626 Colony Forming Units per gram in just one week. There was a significant difference in the diversity found from week 1 to week 4. About 40% of the diversity for the pristine microplastic biofilm was seen as light-yellow dots and about 60% of these dots were seen on the aged microplastic biofilms in both weeks. As the microplastics were submerged in the lake water, new phenotypes emerged varying from week 1 to week 4 and from pristine to aged microplastic biofilms. Generally, it was found that as the microplastics stay in the environment there is more biofilm on the particles. The aged microplastics have a larger amount of biofouling, and the pristine microplastic biofilms were found to have more diversity of phenotypes.
-see the additional "abstract.pdf" document for formatting
In arid environments like Phoenix, many professional and residential outdoor spaces are cooled by the use of misting systems. These systems spray a fine mist of water droplets that cool down the surrounding air through the endothermic evaporation process. When the water droplets evaporate, they leave behind dissolved material that is present in the water, generating ambient particulate matter (PM). Thus, misting systems are a point source of PM. Currently there is no information on their impact on air quality in close proximity to these systems, or on the chemical composition of the particulate matter generated by the evaporating mist.
In this project, PM concentrations are found to increase on average by a factor of 8 from ambient levels in the vicinity of a residential misting system in controlled experiments. PM concentrations in public places that use misting systems are also investigated. The PM10 concentrations in public places ranged from 0.102 ± 0.010 mg m-3 to 1.47 ± 0.15 mg m-3, and PM2.5 ranged from 0.095 ± 0.010 mg m-3 to 0.99 ± 0.10 mg m-3. Air quality index (AQI) values based on these concentrations indicate that these levels of PM range from unhealthy to hazardous in most cases. PM concentrations tend to decrease after remaining relatively constant with increasing distance from misting systems. Chemical data reveal that chloride and magnesium ions may be used as tracers of aerosolized water from misting systems. The average chloride concentration was 71 µg m-3 in misting samples and below the detection limit for Cl- (< 8.2 µg m-3) in ambient samples. The average magnesium concentration was 11.7 µg m-3 in misting samples and 0.23 µg m-3 in ambient samples.