Matching Items (49)
Description

Original exhibit panel text and an associated interview with ASU faculty Charles Backus and Harvey Bryan for the exhibit presented at the Luhrs Gallery, Hayden Library, Fall, 2013.

ContributorsSpindler, Rob (Curator) / Backus, Charles (Interviewee) / Bryan, Harvey (Interviewee)
Created2013-07-01
ContributorsSpindler, Rob (Curator) / Backus, Charles (Interviewee) / Bryan, Harvey (Interviewee)
Created2013-07-01
ContributorsSpindler, Rob (Curator) / Backus, Charles (Interviewee) / Bryan, Harvey (Interviewee)
Created2013-07-01
150039-Thumbnail Image.png
Description
The intent of this research is to determine if cool roofs lead to increased energy use in the U.S. and if so, in what climates. Directed by the LEED environmental building rating system, cool roofs are increasingly specified in an attempt to mitigate urban heat island effect. A typical single

The intent of this research is to determine if cool roofs lead to increased energy use in the U.S. and if so, in what climates. Directed by the LEED environmental building rating system, cool roofs are increasingly specified in an attempt to mitigate urban heat island effect. A typical single story retail building was simulated using eQUEST energy software across seven different climatic zones in the U.S.. Two roof types are varied, one with a low solar reflectance index of 30 (typical bituminous roof), and a roof with SRI of 90 (high performing membrane roof). The model also varied the perimeter / core fraction, internal loads, and schedule of operations. The data suggests a certain point at which a high SRI roofing finish results in energy penalties over the course of the year in climate zones which are heating driven. Climate zones 5 and above appear to be the flipping point, beyond which the application of a high SRI roof creates sufficient heating penalties to outweigh the cooling energy benefits.
ContributorsLee, John (Author) / Bryan, Harvey (Thesis advisor) / Marlin, Marlin (Committee member) / Ramalingam, Muthukumar (Committee member) / Arizona State University (Publisher)
Created2011
149726-Thumbnail Image.png
Description
In recent years, the length of time people use and keep belongings has decreased. With the acceptance of short-lived furniture and inexpensive replacements, the American mentality has shifted to thinking that discarding furniture is normal, often in the guise of recycling. Americans are addicted to landfills. The high cost of

In recent years, the length of time people use and keep belongings has decreased. With the acceptance of short-lived furniture and inexpensive replacements, the American mentality has shifted to thinking that discarding furniture is normal, often in the guise of recycling. Americans are addicted to landfills. The high cost of landfill real estate and other considerable ecological impacts created by the manufacturing of furniture should persuade people to give their belongings a longer life, but in reality, furniture is often prematurely discarded. This grounded theory study takes a multi-method approach to analyze why some types of furniture are kept longer and to theorize about new ways to design and sell furniture that lasts well past its warranty. Case studies bring new insight into designer intention, manufacturer intent, the world of auction-worthy collectables and heirlooms, why there is a booming second-hand furniture market and the growing importance of informed interior designers and architects who specify or help clients choose interior furnishings. An environmental life cycle assessment compares how the length of furniture life affects environmental impacts. A product's life could continue for generations if properly maintained. Designers and manufacturers hoping to promote longevity can apply the conclusions of this report in bringing new pieces to the market that have a much longer life span. This study finds areas of opportunity that promote user attachment, anticipate future repurposing, and provide services. This thinking envisions a paradigm for furniture that can re-invent itself over multiple generations of users, and ultimately lead to a new wave of desirable heirloom furniture.
ContributorsIngham, Sarah (Author) / White, Philip (Thesis advisor) / Wolf, Peter (Committee member) / Underhill, Michael (Committee member) / Arizona State University (Publisher)
Created2011
149888-Thumbnail Image.png
Description
ABSTRACT In an attempt to advocate body-conscious design and healing work environments, this research study of holistic health in the workplace explores cognitive, social and physical well-being in four small US offices that are between 1000 and 4000 square feet and employ three to twelve employees. Holistic health, as pursued

ABSTRACT In an attempt to advocate body-conscious design and healing work environments, this research study of holistic health in the workplace explores cognitive, social and physical well-being in four small US offices that are between 1000 and 4000 square feet and employ three to twelve employees. Holistic health, as pursued in this research, includes social health, emotional health and physical health. These three factors of holistic health have been identified and investigated in this study: biophilia: peoples' love and affiliation with other species and the natural environment; ergonomics: the relationship between the human body, movement, the immediate environment and productivity; and exercise: exertion of the body to obtain physical fitness. This research study proposes that employees and employers of these four participating workplaces desire mobility and resources in the workplace that support holistic health practices involving biophilia, ergonomics, and exercise. Literature review of holistic health and the holistic health factors of this research topic support the idea that interaction with other species can be healing, ergonomic body-conscious furniture and equipment increase productivity, limit body aches, pains and health costs; and exercise stimulates the mind and body, increasing productivity. This study has been conducted primarily with qualitative and flexible research approaches using observation, survey, interview and pedometer readings as methods for data collection. Two small corporate franchise financial institutions and two small private healthcare providers from both Arizona and Georgia participated in this study. Each office volunteered one employer and two employee participants. Of the holistic health factors considered in these four case studies, this study found that a majority of participants equally valued emotional health, social health and physical health. A majority of participants declared a preference for workplace environments with serene natural environments with outdoor spaces and interaction with other species, work environments with body-conscious furniture, equipment and workstations, as well as exercise space and equipment. As these particular workplace environments affirmed value for elements of the factors biophilia, ergonomics and exercise, all three factors are considered valueable within the workplaces of these case studies. Furthermore, factors that were said to contribute to personal productivity in participating workplaces were found as well as sacrifices that participants stated they would be willing to make in order to implement their preferred work environment(s). In addition, this study recorded and calculated average miles walked by participants in each workplace as well as existing incentives and descriptions of ideal work environments. Implications of this research study involve interior design, industrial design and fashion design that can accommodate the desires of the four participating workplaces. Major design implications involve accommodating these particular workplaces to provide personnel with opportunities for holistic health in working environments. More specific implications of office related design involve providing access to natural environments, body-conscious equipment and spaces, as well as opportunities for exercise and social interaction. These elements of the factors biophilia, ergonomics and exercise were found to be said to contribute to cognitive, social and physical health.
ContributorsMcEwan, April (Author) / White, Philip (Thesis advisor) / Shraiky, James (Committee member) / Barry, Rebecca (Committee member) / Arizona State University (Publisher)
Created2011
149949-Thumbnail Image.png
Description
The green building movement has been an effective catalyst in reducing energy demands of buildings and a large number of `green' certified buildings have been in operation for several years. Whether these buildings are actually performing as intended, and if not, identifying specific causes for this discrepancy falls into the

The green building movement has been an effective catalyst in reducing energy demands of buildings and a large number of `green' certified buildings have been in operation for several years. Whether these buildings are actually performing as intended, and if not, identifying specific causes for this discrepancy falls into the general realm of post-occupancy evaluation (POE). POE involves evaluating building performance in terms of energy-use, indoor environmental quality, acoustics and water-use; the first aspect i.e. energy-use is addressed in this thesis. Normally, a full year or more of energy-use and weather data is required to determine the actual post-occupancy energy-use of buildings. In many cases, either measured building performance data is not available or the time and cost implications may not make it feasible to invest in monitoring the building for a whole year. Knowledge about the minimum amount of measured data needed to accurately capture the behavior of the building over the entire year can be immensely beneficial. This research identifies simple modeling techniques to determine best time of the year to begin in-situ monitoring of building energy-use, and the least amount of data required for generating acceptable long-term predictions. Four analysis procedures are studied. The short-term monitoring for long-term prediction (SMLP) approach and dry-bulb temperature analysis (DBTA) approach allow determining the best time and duration of the year for in-situ monitoring to be performed based only on the ambient temperature data of the location. Multivariate change-point (MCP) modeling uses simulated/monitored data to determine best monitoring period of the year. This is also used to validate the SMLP and DBTA approaches. The hybrid inverse modeling method-1 predicts energy-use by combining a short dataset of monitored internal loads with a year of utility-bills, and hybrid inverse method-2 predicts long term building performance using utility-bills only. The results obtained show that often less than three to four months of monitored data is adequate for estimating the annual building energy use, provided that the monitoring is initiated at the right time, and the seasonal as well as daily variations are adequately captured by the short dataset. The predictive accuracy of the short data-sets is found to be strongly influenced by the closeness of the dataset's mean temperature to the annual average temperature. The analysis methods studied would be very useful for energy professionals involved in POE.
ContributorsSingh, Vipul (Author) / Reddy, T. Agami (Thesis advisor) / Bryan, Harvey (Committee member) / Addison, Marlin (Committee member) / Arizona State University (Publisher)
Created2011
150100-Thumbnail Image.png
Description
This study examines the applicability of high dynamic range (HDR) imagery as a diagnostic tool for studying lighting quality in interior environments. It originates from the limitations in lighting quality assessments, particularly from the problematic nature of measuring luminance contrast--a significant lighting quality definer. In this research, HDR imaging method

This study examines the applicability of high dynamic range (HDR) imagery as a diagnostic tool for studying lighting quality in interior environments. It originates from the limitations in lighting quality assessments, particularly from the problematic nature of measuring luminance contrast--a significant lighting quality definer. In this research, HDR imaging method is studied systematically and in detail via extensive camera calibration tests considering the effect of lens and light source geometry (i.e. vignetting, point spread and modulation transfer functions), in-camera variables (i.e. spectral response, sensor sensitivity, metering mode,), and environmental variables (i.e. ambient light level, surface color and reflectance, light source spectral power distribution) on the accuracy of HDR-image-derived luminance data. The calibration test findings are used to create camera setup and calibration guidelines for future research, especially to help minimize errors in image extracted lighting data. The findings are also utilized to demonstrate the viability of the tool in a real world setting--an office environment combining vertical and horizontal tasks. Via the quasi-experimental setup, the relationship between line of sight and perceived luminance contrast ratios are studied using HDR images. Future research can benefit from the calibration guidelines to minimize HDR-based luminance estimation errors. The proposed tool can be used and tested in different contexts and tasks with varying user groups for revising the former luminance-contrast guidelines as well as surface reflectance recommendations.
ContributorsTural, Mehmedalp (Author) / Bryan, Harvey (Thesis advisor) / Kroelinger, Michael D. (Committee member) / Ozel, Filiz (Committee member) / Arizona State University (Publisher)
Created2011
151819-Thumbnail Image.png
Description
Research has demonstrated that temperature and relative humidity substantially influence overall perceptions of indoor air quality (Fang, Clausen, & Fanger, 1998). This finding places temperature quality as a high priority, especially for vulnerable adults over 60. Temperature extremes and fluctuation, as well as the perception of those conditions, affect physical

Research has demonstrated that temperature and relative humidity substantially influence overall perceptions of indoor air quality (Fang, Clausen, & Fanger, 1998). This finding places temperature quality as a high priority, especially for vulnerable adults over 60. Temperature extremes and fluctuation, as well as the perception of those conditions, affect physical performance, thermal comfort and health of older adults (Chatonnet & Cabanac, 1965, pp. 185-6; Fumiharu, Watanabe, Park, Shephard, & Aoyagi, 2005; Heijs & Stringer, 1988). The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) and the International Organization for Standardization (ISO) have developed thermal-comfort standards for working-age, healthy individuals. None of these standards address the physiological and psychological needs of older adults (ASHRAE Standard 55, 2010; ISO-7730, 2005). This dissertation investigates the impacts of thermal conditions on self-reported health and perceived comfort for older adults, hypothesizing that warmer and more-table indoor thermal conditions will increase the health and perceived comfort of these adults. To this end, a new set of thermal comfort metrics was designed and tested to address the thermal preferences of older adults. The SENIOR COMFORT Metrics 2013 outlined new thresholds for optimal indoor high and low temperatures and set limits on thermal variability over time based on the ASHRAE-55 2010 model. This study was conducted at Sunnyslope Manor, a multi-unit, public-housing complex in the North Phoenix. Nearly 60% (76 of 118) of the residents (aged 62-82) were interviewed using a 110-question, self-reporting survey in 73 apartment units. A total of 40 questions and 20 sub-questions addressing perceptions of comfort, pain, sleep patterns, injuries, and mood were extracted from this larger health condition survey to assess health and thermal comfort. Indoor environmental thermal measurements included temperature in three locations: kitchen, living area, and bedroom and data were recorded every 15 minutes over 5 full days and 448 points. Study results start to indicate that older adults for Sunnyslope Manor preferred temperatures between 76 and 82.5 degrees Fahrenheit and that lower temperatures as outlined by ASHRAE-55 2010 increases the rate of injuries and mood changes in older adults among other findings.
ContributorsFonseca, Ernesto (Author) / Bryan, Harvey (Thesis advisor) / Ahrentzen, Sherry (Committee member) / Shea, Kimberly (Committee member) / Arizona State University (Publisher)
Created2013
151894-Thumbnail Image.png
Description
With the desire of high standards of comfort, huge amount of energy is being consumed to maintain the indoor environment. In US building consumes 40% of the total primary energy while residential buildings consume about 21%. A large proportion of this consumption is due to cooling of buildings. Deteriorating environmental

With the desire of high standards of comfort, huge amount of energy is being consumed to maintain the indoor environment. In US building consumes 40% of the total primary energy while residential buildings consume about 21%. A large proportion of this consumption is due to cooling of buildings. Deteriorating environmental conditions due to excessive energy use suggest that we should look at passive designs and renewable energy opportunities to supply the required comfort. Phoenix gets about 300 days of clear sky every year. It also witnesses large temperature variations from night and day. The humidity ratio almost always stays below the 50% mark. With more than six months having outside temperatures more than 75 oF, night sky radiative cooling promise to be an attractive means to cool the buildings during summer. This technique can be useful for small commercial facilities or residential buildings. The roof ponds can be made more effective by covering them with Band Filters. These band filters block the solar heat gain and allow the water to cool down to lower temperatures. It also reduces the convection heat gain. This helps rood ponds maintain lower temperatures and provide more cooling then an exposed pond. 50 μm Polyethylene band filter is used in this study. Using this band filter, roof ponds can be made up to 10% more effective. About 45% of the energy required to cool a typical residential building in summer can be saved.
ContributorsSiddiqui, Mohd. Aqdus (Author) / Bryan, Harvey (Thesis advisor) / Reddy, T Agami (Committee member) / Kroelinger, Michael D. (Committee member) / Arizona State University (Publisher)
Created2013