Matching Items (45)
150039-Thumbnail Image.png
Description
The intent of this research is to determine if cool roofs lead to increased energy use in the U.S. and if so, in what climates. Directed by the LEED environmental building rating system, cool roofs are increasingly specified in an attempt to mitigate urban heat island effect. A typical single

The intent of this research is to determine if cool roofs lead to increased energy use in the U.S. and if so, in what climates. Directed by the LEED environmental building rating system, cool roofs are increasingly specified in an attempt to mitigate urban heat island effect. A typical single story retail building was simulated using eQUEST energy software across seven different climatic zones in the U.S.. Two roof types are varied, one with a low solar reflectance index of 30 (typical bituminous roof), and a roof with SRI of 90 (high performing membrane roof). The model also varied the perimeter / core fraction, internal loads, and schedule of operations. The data suggests a certain point at which a high SRI roofing finish results in energy penalties over the course of the year in climate zones which are heating driven. Climate zones 5 and above appear to be the flipping point, beyond which the application of a high SRI roof creates sufficient heating penalties to outweigh the cooling energy benefits.
ContributorsLee, John (Author) / Bryan, Harvey (Thesis advisor) / Marlin, Marlin (Committee member) / Ramalingam, Muthukumar (Committee member) / Arizona State University (Publisher)
Created2011
150340-Thumbnail Image.png
Description
There is a conflict in the profession of interior design over regulation through legislation. For some organizations and individuals, regulation via legislation is the next perceived step in the professionalization process which has been evolving for over 40 years and is needed to protect the health, safety and welfare (HSW)

There is a conflict in the profession of interior design over regulation through legislation. For some organizations and individuals, regulation via legislation is the next perceived step in the professionalization process which has been evolving for over 40 years and is needed to protect the health, safety and welfare (HSW) of the public. For other organizations and individuals, legislation is deemed unnecessary and an affront to the free trade market and serves only to create anti-competitive barriers resulting in the formation of a "design cartel" (Campo-Flores, 2011; Carpenter, 2007). Research exists on the professionalization of interior design and on the reasons stated for and against legislation (ASID, 2010, Anderson, Honey, Dudek, 2007, Martin, 2008). However, there is little research on understanding how the actual stake-holders view legislation. For the purpose of this research, the stake-holders are the professional interior designers themselves. The purpose of this study was to examine the current status of relevant issues to the subject of regulation in interior design and to pose the question if there is an option to legislation. If so, could third party certification be an acceptable alternative? An on-line survey was developed and posted on interior design networking sites on LinkedIn. The results of the survey suggest that interior designers are completely divided on the issue of legislation but favorably view certification. The survey has also revealed the lack of understanding of the legislative process in interior design and confusion in the role that interior design organizations play. The study has also revealed that interior designers identify the distorted view the public has of this industry as a problem. Interior designers surveyed in this study see a need to separate commercial and residential interior design. Overall, this study has concluded that interior designers would actually prefer a certification process to legislation.
ContributorsPliess, Catherine (Author) / Bender, Diane (Thesis advisor) / Crewe, Katherine (Committee member) / Kroelinger, Michael D. (Committee member) / Arizona State University (Publisher)
Created2011
149873-Thumbnail Image.png
Description
Passive cooling designs & technologies offer great promise to lower energy use in buildings. Though the working principles of these designs and technologies are well understood, simplified tools to quantitatively evaluate their performance are lacking. Cooling by night ventilation, which is the topic of this research, is one of the

Passive cooling designs & technologies offer great promise to lower energy use in buildings. Though the working principles of these designs and technologies are well understood, simplified tools to quantitatively evaluate their performance are lacking. Cooling by night ventilation, which is the topic of this research, is one of the well known passive cooling technologies. The building's thermal mass can be cooled at night by ventilating the inside of the space with the relatively lower outdoor air temperatures, thereby maintaining lower indoor temperatures during the warmer daytime period. Numerous studies, both experimental and theoretical, have been performed and have shown the effectiveness of the method to significantly reduce air conditioning loads or improve comfort levels in those climates where the night time ambient air temperature drops below that of the indoor air. The impact of widespread adoption of night ventilation cooling can be substantial, given the large fraction of energy consumed by air conditioning of buildings (about 12-13% of the total electricity use in U.S. buildings). Night ventilation is relatively easy to implement with minimal design changes to existing buildings. Contemporary mathematical models to evaluate the performance of night ventilation are embedded in detailed whole building simulation tools which require a certain amount of expertise and is a time consuming approach. This research proposes a methodology incorporating two models, Heat Transfer model and Thermal Network model, to evaluate the effectiveness of night ventilation. This methodology is easier to use and the run time to evaluate the results is faster. Both these models are approximations of thermal coupling between thermal mass and night ventilation in buildings. These models are modifications of existing approaches meant to model dynamic thermal response in buildings subject to natural ventilation. Effectiveness of night ventilation was quantified by a parameter called the Discomfort Reduction Factor (DRF) which is the index of reduction of occupant discomfort levels during the day time from night ventilation. Daily and Monthly DRFs are calculated for two climate zones and three building heat capacities. It is verified that night ventilation is effective in seasons and regions when day temperatures are between 30 oC and 36 oC and night temperatures are below 20 oC. The accuracy of these models may be lower than using a detailed simulation program but the loss in accuracy in using these tools more than compensates for the insights provided and better transparency in the analysis approach and results obtained.
ContributorsEndurthy, Akhilesh Reddy (Author) / Reddy, T Agami (Thesis advisor) / Phelan, Patrick (Committee member) / Addison, Marlin (Committee member) / Arizona State University (Publisher)
Created2011
149949-Thumbnail Image.png
Description
The green building movement has been an effective catalyst in reducing energy demands of buildings and a large number of `green' certified buildings have been in operation for several years. Whether these buildings are actually performing as intended, and if not, identifying specific causes for this discrepancy falls into the

The green building movement has been an effective catalyst in reducing energy demands of buildings and a large number of `green' certified buildings have been in operation for several years. Whether these buildings are actually performing as intended, and if not, identifying specific causes for this discrepancy falls into the general realm of post-occupancy evaluation (POE). POE involves evaluating building performance in terms of energy-use, indoor environmental quality, acoustics and water-use; the first aspect i.e. energy-use is addressed in this thesis. Normally, a full year or more of energy-use and weather data is required to determine the actual post-occupancy energy-use of buildings. In many cases, either measured building performance data is not available or the time and cost implications may not make it feasible to invest in monitoring the building for a whole year. Knowledge about the minimum amount of measured data needed to accurately capture the behavior of the building over the entire year can be immensely beneficial. This research identifies simple modeling techniques to determine best time of the year to begin in-situ monitoring of building energy-use, and the least amount of data required for generating acceptable long-term predictions. Four analysis procedures are studied. The short-term monitoring for long-term prediction (SMLP) approach and dry-bulb temperature analysis (DBTA) approach allow determining the best time and duration of the year for in-situ monitoring to be performed based only on the ambient temperature data of the location. Multivariate change-point (MCP) modeling uses simulated/monitored data to determine best monitoring period of the year. This is also used to validate the SMLP and DBTA approaches. The hybrid inverse modeling method-1 predicts energy-use by combining a short dataset of monitored internal loads with a year of utility-bills, and hybrid inverse method-2 predicts long term building performance using utility-bills only. The results obtained show that often less than three to four months of monitored data is adequate for estimating the annual building energy use, provided that the monitoring is initiated at the right time, and the seasonal as well as daily variations are adequately captured by the short dataset. The predictive accuracy of the short data-sets is found to be strongly influenced by the closeness of the dataset's mean temperature to the annual average temperature. The analysis methods studied would be very useful for energy professionals involved in POE.
ContributorsSingh, Vipul (Author) / Reddy, T. Agami (Thesis advisor) / Bryan, Harvey (Committee member) / Addison, Marlin (Committee member) / Arizona State University (Publisher)
Created2011
150100-Thumbnail Image.png
Description
This study examines the applicability of high dynamic range (HDR) imagery as a diagnostic tool for studying lighting quality in interior environments. It originates from the limitations in lighting quality assessments, particularly from the problematic nature of measuring luminance contrast--a significant lighting quality definer. In this research, HDR imaging method

This study examines the applicability of high dynamic range (HDR) imagery as a diagnostic tool for studying lighting quality in interior environments. It originates from the limitations in lighting quality assessments, particularly from the problematic nature of measuring luminance contrast--a significant lighting quality definer. In this research, HDR imaging method is studied systematically and in detail via extensive camera calibration tests considering the effect of lens and light source geometry (i.e. vignetting, point spread and modulation transfer functions), in-camera variables (i.e. spectral response, sensor sensitivity, metering mode,), and environmental variables (i.e. ambient light level, surface color and reflectance, light source spectral power distribution) on the accuracy of HDR-image-derived luminance data. The calibration test findings are used to create camera setup and calibration guidelines for future research, especially to help minimize errors in image extracted lighting data. The findings are also utilized to demonstrate the viability of the tool in a real world setting--an office environment combining vertical and horizontal tasks. Via the quasi-experimental setup, the relationship between line of sight and perceived luminance contrast ratios are studied using HDR images. Future research can benefit from the calibration guidelines to minimize HDR-based luminance estimation errors. The proposed tool can be used and tested in different contexts and tasks with varying user groups for revising the former luminance-contrast guidelines as well as surface reflectance recommendations.
ContributorsTural, Mehmedalp (Author) / Bryan, Harvey (Thesis advisor) / Kroelinger, Michael D. (Committee member) / Ozel, Filiz (Committee member) / Arizona State University (Publisher)
Created2011
152294-Thumbnail Image.png
Description
The study of lighting design has important implications for consumer behavior and is an important aspect of consideration for the retail industry. In today's global economy consumers can come from a number of cultural backgrounds. It is important to understand various cultures' perceptions of lighting design in order for retailers

The study of lighting design has important implications for consumer behavior and is an important aspect of consideration for the retail industry. In today's global economy consumers can come from a number of cultural backgrounds. It is important to understand various cultures' perceptions of lighting design in order for retailers to better understand how to use lighting as a benefit to provide consumers with a desirable shopping experience. This thesis provides insight into the effects of ambient lighting on product perception among Americans and Middle Easterners. Both cultural groups' possess significant purchasing power in the worldwide market place. This research will allow marketers, designers and consumers a better understanding of how culture may play a role in consumer perceptions and behavior Results of this study are based on data gathered from 164 surveys from individuals of American and Middle Eastern heritage. Follow up interviews were also conducted to examine the nuances of product perception and potential differences across cultures. This study, using qualitative and quantitative methods, was executed using a Sequential Explanatory Strategy. Survey data were analyzed to uncover significant correlations and relationships using measures of descriptive analysis, analysis of variance (ANOVA), and regression analysis. Interviews were analyzed using theme-based coding and reported in narrative form. The results suggest that lighting does in fact have an impact on product perception, however despite minor differences, this perception does not vary much between individuals from American and Middle Eastern cultures. It was found that lighting could affect price and quality perception with reference to store-image and store atmospherics. Additionally, lighting has a higher impact on subjective impressions of product (such as Freshness, Pleasantness, and Attractiveness), more than Price and Quality perceptions. This study suggests that particular lighting characteristics could be responsible for differences in product perception between these two cultures. This is important to note for lighting designers and marketers to create retail atmospheres that are preferable to both cultures.
ContributorsAlsharhan, Dalal Anwar (Author) / Kroelinger, Michael D. (Thesis advisor) / Eaton, John (Committee member) / Heywood, William (Committee member) / Arizona State University (Publisher)
Created2013
152295-Thumbnail Image.png
Description
ABSTRACT Recent studies indicate that top-performing companies have higher-performing work environments than average companies. They receive higher scores for worker satisfaction with their overall physical work environment as well as higher effectiveness ratings for their workspaces (Gensler, 2008; Harter et al., 2003). While these studies indicate a relationship between effective

ABSTRACT Recent studies indicate that top-performing companies have higher-performing work environments than average companies. They receive higher scores for worker satisfaction with their overall physical work environment as well as higher effectiveness ratings for their workspaces (Gensler, 2008; Harter et al., 2003). While these studies indicate a relationship between effective office design and satisfaction they have not explored which specific space types may contribute to workers' overall satisfaction with their physical work environment. Therefore, the purpose of this study is to explore the relationship between workers' overall satisfaction with their physical work environments and their perception of the effectiveness of spaces designed for Conceptual Age work including learning, focusing, collaborating, and socializing tasks. This research is designed to identify which workspace types are related to workers' satisfaction with their overall work environment and which are perceived to be most and least effective. To accomplish this two primary and four secondary research questions were developed for this study. The first primary question considers overall workers' satisfaction with their overall physical work environments (offices, workstations, hallways, common areas, reception, waiting areas, etc.) related to the effective use of work mode workspaces (learning, focusing, collaborating, socializing). The second primary research question was developed to identify which of the four work mode space types had the greatest and least relationship to workers' satisfaction with the overall physical work environment. Secondary research questions were developed to address workers' perceptions of effectiveness of each space type. This research project used data from a previous study collected from 2007 to 2012. Responses were from all staff levels of US office-based office workers and resulted in a blind sample of approximately 48,000 respondents. The data for this study were developed from SPSS data reports that included descriptive data and Pearson correlations. Findings were developed from those statistics using coefficient of determination.
ContributorsHarmon-Vaughan, Elizabeth (Author) / Kroelinger, Michael D. (Thesis advisor) / Bernardi, Jose (Committee member) / Ozel, Filiz (Committee member) / Arizona State University (Publisher)
Created2013
151819-Thumbnail Image.png
Description
Research has demonstrated that temperature and relative humidity substantially influence overall perceptions of indoor air quality (Fang, Clausen, & Fanger, 1998). This finding places temperature quality as a high priority, especially for vulnerable adults over 60. Temperature extremes and fluctuation, as well as the perception of those conditions, affect physical

Research has demonstrated that temperature and relative humidity substantially influence overall perceptions of indoor air quality (Fang, Clausen, & Fanger, 1998). This finding places temperature quality as a high priority, especially for vulnerable adults over 60. Temperature extremes and fluctuation, as well as the perception of those conditions, affect physical performance, thermal comfort and health of older adults (Chatonnet & Cabanac, 1965, pp. 185-6; Fumiharu, Watanabe, Park, Shephard, & Aoyagi, 2005; Heijs & Stringer, 1988). The American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) and the International Organization for Standardization (ISO) have developed thermal-comfort standards for working-age, healthy individuals. None of these standards address the physiological and psychological needs of older adults (ASHRAE Standard 55, 2010; ISO-7730, 2005). This dissertation investigates the impacts of thermal conditions on self-reported health and perceived comfort for older adults, hypothesizing that warmer and more-table indoor thermal conditions will increase the health and perceived comfort of these adults. To this end, a new set of thermal comfort metrics was designed and tested to address the thermal preferences of older adults. The SENIOR COMFORT Metrics 2013 outlined new thresholds for optimal indoor high and low temperatures and set limits on thermal variability over time based on the ASHRAE-55 2010 model. This study was conducted at Sunnyslope Manor, a multi-unit, public-housing complex in the North Phoenix. Nearly 60% (76 of 118) of the residents (aged 62-82) were interviewed using a 110-question, self-reporting survey in 73 apartment units. A total of 40 questions and 20 sub-questions addressing perceptions of comfort, pain, sleep patterns, injuries, and mood were extracted from this larger health condition survey to assess health and thermal comfort. Indoor environmental thermal measurements included temperature in three locations: kitchen, living area, and bedroom and data were recorded every 15 minutes over 5 full days and 448 points. Study results start to indicate that older adults for Sunnyslope Manor preferred temperatures between 76 and 82.5 degrees Fahrenheit and that lower temperatures as outlined by ASHRAE-55 2010 increases the rate of injuries and mood changes in older adults among other findings.
ContributorsFonseca, Ernesto (Author) / Bryan, Harvey (Thesis advisor) / Ahrentzen, Sherry (Committee member) / Shea, Kimberly (Committee member) / Arizona State University (Publisher)
Created2013
151894-Thumbnail Image.png
Description
With the desire of high standards of comfort, huge amount of energy is being consumed to maintain the indoor environment. In US building consumes 40% of the total primary energy while residential buildings consume about 21%. A large proportion of this consumption is due to cooling of buildings. Deteriorating environmental

With the desire of high standards of comfort, huge amount of energy is being consumed to maintain the indoor environment. In US building consumes 40% of the total primary energy while residential buildings consume about 21%. A large proportion of this consumption is due to cooling of buildings. Deteriorating environmental conditions due to excessive energy use suggest that we should look at passive designs and renewable energy opportunities to supply the required comfort. Phoenix gets about 300 days of clear sky every year. It also witnesses large temperature variations from night and day. The humidity ratio almost always stays below the 50% mark. With more than six months having outside temperatures more than 75 oF, night sky radiative cooling promise to be an attractive means to cool the buildings during summer. This technique can be useful for small commercial facilities or residential buildings. The roof ponds can be made more effective by covering them with Band Filters. These band filters block the solar heat gain and allow the water to cool down to lower temperatures. It also reduces the convection heat gain. This helps rood ponds maintain lower temperatures and provide more cooling then an exposed pond. 50 μm Polyethylene band filter is used in this study. Using this band filter, roof ponds can be made up to 10% more effective. About 45% of the energy required to cool a typical residential building in summer can be saved.
ContributorsSiddiqui, Mohd. Aqdus (Author) / Bryan, Harvey (Thesis advisor) / Reddy, T Agami (Committee member) / Kroelinger, Michael D. (Committee member) / Arizona State University (Publisher)
Created2013
151916-Thumbnail Image.png
Description
Through manipulation of adaptable opportunities available within a given environment, individuals become active participants in managing personal comfort requirements, by exercising control over their comfort without the assistance of mechanical heating and cooling systems. Similarly, continuous manipulation of a building skin's form, insulation, porosity, and transmissivity qualities exerts control over

Through manipulation of adaptable opportunities available within a given environment, individuals become active participants in managing personal comfort requirements, by exercising control over their comfort without the assistance of mechanical heating and cooling systems. Similarly, continuous manipulation of a building skin's form, insulation, porosity, and transmissivity qualities exerts control over the energy exchanged between indoor and outdoor environments. This research uses four adaptive response variables in a modified software algorithm to explore an adaptive building skin's potential in reacting to environmental stimuli with the purpose of minimizing energy use without sacrificing occupant comfort. Results illustrate that significant energy savings can be realized with adaptive envelopes over static building envelopes even under extreme summer and winter climate conditions; that the magnitude of these savings are dependent on climate and orientation; and that occupant thermal comfort can be improved consistently over comfort levels achieved by optimized static building envelopes. The resulting adaptive envelope's unique climate-specific behavior could inform designers in creating an intelligent kinetic aesthetic that helps facilitate adaptability and resiliency in architecture.
ContributorsErickson, James (Author) / Bryan, Harvey (Thesis advisor) / Addison, Marlin (Committee member) / Kroelinger, Michael D. (Committee member) / Reddy, T. Agami (Committee member) / Arizona State University (Publisher)
Created2013