Matching Items (2)
Filtering by

Clear all filters

155565-Thumbnail Image.png
Description
The American Diabetes Association reports that diabetes costs $322 billion annually and affects 29.1 million Americans. The high out-of-pocket cost of managing diabetes can lead to noncompliance causing serious and expensive complications. There is a large market potential for a more cost-effective alternative to the current market standard of screen-printed

The American Diabetes Association reports that diabetes costs $322 billion annually and affects 29.1 million Americans. The high out-of-pocket cost of managing diabetes can lead to noncompliance causing serious and expensive complications. There is a large market potential for a more cost-effective alternative to the current market standard of screen-printed self-monitoring blood glucose (SMBG) strips. Additive manufacturing, specifically 3D printing, is a developing field that is growing in popularity and functionality. 3D printers are now being used in a variety of applications from consumer goods to medical devices. Healthcare delivery will change as the availability of 3D printers expands into patient homes, which will create alternative and more cost-effective methods of monitoring and managing diseases, such as diabetes. 3D printing technology could transform this expensive industry. A 3D printed sensor was designed to have similar dimensions and features to the SMBG strips to comply with current manufacturing standards. To make the sensor electrically active, various conductive filaments were tested and the conductive graphene filament was determined to be the best material for the sensor. Experiments were conducted to determine the optimal print settings for printing this filament onto a mylar substrate, the industry standard. The reagents used include a mixture of a ferricyanide redox mediator and flavin adenine dinucleotide dependent glucose dehydrogenase. With these materials, each sensor only costs $0.40 to print and use. Before testing the 3D printed sensor, a suitable design, voltage range, and redox probe concentration were determined. Experiments demonstrated that this novel 3D printed sensor can accurately correlate current output to glucose concentration. It was verified that the sensor can accurately detect glucose levels from 25 mg/dL to 400 mg/dL, with an R2 correlation value as high as 0.97, which was critical as it covered hypoglycemic to hyperglycemic levels. This demonstrated that a 3D-printed sensor was created that had characteristics that are suitable for clinical use. This will allow diabetics to print their own test strips at home at a much lower cost compared to SMBG strips, which will reduce noncompliance due to the high cost of testing. In the future, this technology could be applied to additional biomarkers to measure and monitor other diseases.
ContributorsAdams, Anngela (Author) / LaBelle, Jeffrey (Thesis advisor) / Pizziconi, Vincent (Committee member) / Abbas, James (Committee member) / Arizona State University (Publisher)
Created2017
158252-Thumbnail Image.png
Description
Background: Process mining (PM) using event log files is gaining popularity in healthcare to investigate clinical pathways. But it has many unique challenges. Clinical Pathways (CPs) are often complex and unstructured which results in spaghetti-like models. Moreover, the log files collected from the electronic health record (EHR) often contain noisy

Background: Process mining (PM) using event log files is gaining popularity in healthcare to investigate clinical pathways. But it has many unique challenges. Clinical Pathways (CPs) are often complex and unstructured which results in spaghetti-like models. Moreover, the log files collected from the electronic health record (EHR) often contain noisy and incomplete data. Objective: Based on the traditional process mining technique of using event logs generated by an EHR, observational video data from rapid ethnography (RE) were combined to model, interpret, simplify and validate the perioperative (PeriOp) CPs. Method: The data collection and analysis pipeline consisted of the following steps: (1) Obtain RE data, (2) Obtain EHR event logs, (3) Generate CP from RE data, (4) Identify EHR interfaces and functionalities, (5) Analyze EHR functionalities to identify missing events, (6) Clean and preprocess event logs to remove noise, (7) Use PM to compute CP time metrics, (8) Further remove noise by removing outliers, (9) Mine CP from event logs and (10) Compare CPs resulting from RE and PM. Results: Four provider interviews and 1,917,059 event logs and 877 minutes of video ethnography recording EHRs interaction were collected. When mapping event logs to EHR functionalities, the intraoperative (IntraOp) event logs were more complete (45%) when compared with preoperative (35%) and postoperative (21.5%) event logs. After removing the noise (496 outliers) and calculating the duration of the PeriOp CP, the median was 189 minutes and the standard deviation was 291 minutes. Finally, RE data were analyzed to help identify most clinically relevant event logs and simplify spaghetti-like CPs resulting from PM. Conclusion: The study demonstrated the use of RE to help overcome challenges of automatic discovery of CPs. It also demonstrated that RE data could be used to identify relevant clinical tasks and incomplete data, remove noise (outliers), simplify CPs and validate mined CPs.
ContributorsDeotale, Aditya Vijay (Author) / Liu, Huan (Thesis advisor) / Grando, Maria (Thesis advisor) / Manikonda, Lydia (Committee member) / Arizona State University (Publisher)
Created2020