Early detection and treatment of disease is paramount for improving human health and wellness. Micro-scale devices promote new opportunities for the rapid, cost-effective, and accurate identification of altered biological states indicative of disease early-onset; these devices function at a scale more sensitive to numerous biological processes. The application of Micro-Electro-Mechanical

Early detection and treatment of disease is paramount for improving human health and wellness. Micro-scale devices promote new opportunities for the rapid, cost-effective, and accurate identification of altered biological states indicative of disease early-onset; these devices function at a scale more sensitive to numerous biological processes. The application of Micro-Electro-Mechanical Systems (MEMS) in biomedical settings has recently emerged and flourished over course of the last two decades, requiring a deep understanding of material biocompatibility, biosensing sensitively/selectively, biological constraints for artificial tissue/organ replacement, and the regulations in place to ensure device safety. Capitalizing on the inherent physical differences between cancerous and healthy cells, our ultra-thin silicone membrane enables earlier identification of bladder cancer—with a 70% recurrence rate. Building on this breakthrough, we have devised an array to multiplex this sample-analysis in real-time as well as expanding beyond bladder cancer. The introduction of new materials—with novel properties—to augment current and create innovative medical implants requires the careful analysis of material impact on cellular toxicity, mutagenicity, reactivity, and stability. Finally, the achievement of replacing defective biological systems with implanted artificial equivalents that must function within the same biological constraints, have consistent reliability, and ultimately show the promise of improving human health as demonstrated by our hydrogel check valve. The ongoing proliferation, expanding prevalence, and persistent improvement in MEMS devices through greater sensitivity, specificity, and integration with biological processes will undoubtedly bolster medical science with novel MEMS-based diagnostics and therapeutics.
ContributorsPodlevsky, Jennie Hewitt Appel (Author) / Chae, Junseok (Thesis advisor) / Goryll, Michael (Committee member) / Kozicki, Michael (Committee member) / Nikkhah, Mehdi (Committee member) / Arizona State University (Publisher)
Created2018
135403-Thumbnail Image.png
Description
Hydrocephalus is a chronic medical condition characterized by the excessive accumulation of cerebrospinal fluid in the brain. It is estimated that 1-2 of every 1000 babies in the United States is born with congenital hydrocephalus, with many individuals acquiring hydrocephalus later in life through brain injury. Despite these alarming statistics,

Hydrocephalus is a chronic medical condition characterized by the excessive accumulation of cerebrospinal fluid in the brain. It is estimated that 1-2 of every 1000 babies in the United States is born with congenital hydrocephalus, with many individuals acquiring hydrocephalus later in life through brain injury. Despite these alarming statistics, current shunts for the treatment of hydrocephalus display operational failure rates as high as 40-50% within two years following implantation. Failure of current shunts is attributed to complexity of design, external implantation, and the requirement of multiple catheters. The presented hydrogel wafer check valve avoids all the debilitating features of current shunts, relying only on the swelling of hydrogel for operation, and is designed to directly replace failed arachnoid granulations- the brain’s natural cerebrospinal fluid drainage valves. The valve was validated via bench-top (1) hydrodynamic pressure-flow response characterizations, (2) transient response analysis, and (3) overtime performance response in brain-analogous conditions. In-vitro measurements display operation in range of natural CSF draining (cracking pressure, PT ~ 1–110 mmH2O and outflow hydraulic resistance, Rh ~ 24 – 152 mmH2O/mL/min), negligible reverse flow leakages (flow, QO > -10 µL/min), and demonstrate the valve’s operational reproducibility of this new valve as an implantable treatment.
ContributorsAmjad, Usamma Muhammad (Author) / Chae, Junseok (Thesis director) / Appel, Jennie (Committee member) / Chemical Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
173228-Thumbnail Image.png
Description

Walter Edward Dandy studied abnormalities in the developing human brain in the United States in the twentieth century. He collaborated with pediatrician Kenneth Blackfan to provide the first clinical description of Dandy-Walker Syndrome, a congenital brain malformation in which the medial part of the brain, called the cerebellar vermis, is

Walter Edward Dandy studied abnormalities in the developing human brain in the United States in the twentieth century. He collaborated with pediatrician Kenneth Blackfan to provide the first clinical description of Dandy-Walker Syndrome, a congenital brain malformation in which the medial part of the brain, called the cerebellar vermis, is absent. Dandy also described the circulation of cerebral spinal fluid, the clear, watery fluid that surrounds and cushions the brain and spinal cord. That description led Dandy to examine how the impeded flow of cerebral spinal fluid caused congenital hydrocephalus, which occurs when fluid accumulates in the brain causes it to swell. Dandy discovered brain anomalies that primarily develop during embryonic development, and his work helped to detect brain abnormalities.

Created2017-03-02
173237-Thumbnail Image.png
Description

Hydrocephalus is a congenital or acquired disorder characterized by the abnormal accumulation of cerebrospinal fluid within the cavities of the brain, called ventricles. The accumulation of cerebrospinal fluid, the clear fluid surrounding the brain and spinal cord, causes an abnormal widening of the ventricles. The widening creates potentially harmful pressure

Hydrocephalus is a congenital or acquired disorder characterized by the abnormal accumulation of cerebrospinal fluid within the cavities of the brain, called ventricles. The accumulation of cerebrospinal fluid, the clear fluid surrounding the brain and spinal cord, causes an abnormal widening of the ventricles. The widening creates potentially harmful pressure on the tissues of the brain that can result in brain damage or death. The most obvious sign of hydrocephalus is the rapid increase in head circumference or an unusual large head size due to the accumulation of cerebrospinal fluid in the brain. In infants, hydrocephalus can be caused by congenital factors such as malformations of the brain, or acquired factors such as tumors, cysts, meningitis, or bleeding. Treatment after the infant is born can lead to normal cognitive and physical development with few limitations.

Created2017-03-07
Description

Dandy-Walker Syndrome is a congenital brain defect in humans characterized by malformations to the cerebellum, the part of the brain that controls movement, and to the ventricles, the fluid-filled cavities that surround the cerebellum. The syndrome is named for physicians Walter Dandy and Arthur Walker who described associated signs and

Dandy-Walker Syndrome is a congenital brain defect in humans characterized by malformations to the cerebellum, the part of the brain that controls movement, and to the ventricles, the fluid-filled cavities that surround the cerebellum. The syndrome is named for physicians Walter Dandy and Arthur Walker who described associated signs and symptoms of the syndrome in the 1900s. The malformations often develop during embryonic stages. In early infancy, symptoms include slow motor development and a progressive enlargement of the skull due to cerebrospinal fluid accumulation called hydrocephalus. The prognosis of Dandy-Walker syndrome is highly variable, ranging from minor or negligible birth defects to profound malformations, disability, or early death.

Created2017-03-02
173492-Thumbnail Image.png
Description

From February 2003 to December 2010, researchers of the Management of Myelomeningocele Study, or MOMS, clinical trial compared the safety and efficacy of different treatments for a specific type of spina bifida, called myelomeningocele. Myelomeningocele, the most frequent and severe form of spina bifida, is a condition in which the

From February 2003 to December 2010, researchers of the Management of Myelomeningocele Study, or MOMS, clinical trial compared the safety and efficacy of different treatments for a specific type of spina bifida, called myelomeningocele. Myelomeningocele, the most frequent and severe form of spina bifida, is a condition in which the bony spinal column does not develop correctly, which causes an opening of the spine, exposure of the spinal cord, and formation of a small sac containing cerebrospinal fluid. Myelomeningocele affects 3.4 infants per 10,000 live births in the United States and is fatal in ten percent of affected infants. Investigators in the MOMS trial aimed to find a more successful treatment for myelomeningocele through different types of surgery. To accomplish that, they performed prenatal, or in utero, and postnatal repair operations in their study. The MOMS researchers concluded that prenatal repair improved motor and neurologic outcomes, such as the ability to activate and coordinate the muscles and limbs, and reduced the risk for fetal death.

Created2017-11-15
158825-Thumbnail Image.png
Description
BioMEMS has the potential to provide many future tools for life sciences, combined with microfabrication technologies and biomaterials. Especially due to the recent corona 19 epidemic, interest in BioMEMS technology has increased significantly, and the related research has also grown significantly. The field with the highest demand for BioMEMS devices

BioMEMS has the potential to provide many future tools for life sciences, combined with microfabrication technologies and biomaterials. Especially due to the recent corona 19 epidemic, interest in BioMEMS technology has increased significantly, and the related research has also grown significantly. The field with the highest demand for BioMEMS devices is in the medical field. In particular, the implantable device field is the largest sector where cutting-edge BioMEMS technology is applied along with nanotechnology, artificial intelligence, genetic engineering, etc. However, implantable devices used for brain diseases are still very limited because unlike other parts of human organs, the brain is still unknow area which cannot be completely replaceable.To date, the most commercially used, almost only, implantable device for the brain is a shunt system for the treatment of hydrocephalus. The current cerebrospinal fluid (CSF) shunt treatment yields high failure rates: ~40% within first 2 years and 98% within 10 years. These failures lead to high hospital admission rates and repeated invasive surgical procedures, along with reduced quality of life. New treatments are needed to improve the disease burden associated with hydrocephalus. In this research, the proposed catheter-free, completely-passive miniaturized valve is designed to alleviate hydrocephalus at the originating site of the disorder and diminish failure mechanisms associated with current treatment methods. The valve is composed of hydrogel diaphragm structure and polymer or glass outer frame which are 100% bio-compatible material. The valve aims to be implanted between the sub-arachnoid space and the superior sagittal sinus to regulate the CSF flow substituting for the obstructed arachnoid granulations.
A cardiac pacemaker is one of the longest and most widely used implantable devices and the wireless technology is the most widely used with it for easy acquisition of vital signs and rapid disease diagnosis without clinical surgery. But the conventional pacemakers with some wireless technology face some essential complications associated with finite battery life, ultra-vein pacing leads, and risk of infection from device pockets and leads. To solve these problems, wireless cardiac pacemaker operating in fully-passive modality is proposed and demonstrates the promising potential by realizing a prototype and functional evaluating.
ContributorsLee, Seunghyun (Author) / Christen, Jennifer (Thesis advisor) / Goryll, Michael (Committee member) / Nikkhah, Mehdi (Committee member) / Sohn, SungMin (Committee member) / Arizona State University (Publisher)