149529-Thumbnail Image.png
Description
This research work illustrates the use of software packages based on the concept of nu-merical analysis technique to evaluate the electric field and voltage distribution along composite insulators for system voltages ranging from 138 kV up to 1200 kV ac. A part of the calculations was made using the 3D

This research work illustrates the use of software packages based on the concept of nu-merical analysis technique to evaluate the electric field and voltage distribution along composite insulators for system voltages ranging from 138 kV up to 1200 kV ac. A part of the calculations was made using the 3D software package, COULOMB 8.0, based on the concept of Boundary Element Method (BEM). The electric field was calculated under dry and wet conditions. Compo-site insulators experience more electrical stress when compared to porcelain and are also more prone to damage caused by corona activity. The work presented here investigates the effect of corona rings of specific dimensions and bundled conductors on the electric field along composite insulators. Inappropriate placement or dimensions of corona rings could enhance the electric field instead of mitigating it. Corona ring optimization for a 1000 kV composite insulator was per-formed by changing parameters of the ring, such as the diameter of the ring, thickness of the ring tube and the projection of the ring from the high voltage energized end fitting. Grading rings were designed for Ultra High Voltage (UHV) systems that use two units of composite insulators in pa-rallel. The insulation distance, which bears 50% of the total applied voltage, is raised by 61% with the grading ring installed, when compared to the distance without the grading ring. In other words, the electric field and voltage distribution was found to be more linear with the application of grad-ing rings. The second part of this project was carried out using the EPRI designed software EPIC. This is based on the concept of Charge Simulation method (CSM). Comparisons were made be-tween electric field magnitude along composite insulators used for suspension and dead end configuration for system voltages ranging from 138 kV to 500 kV. It was found that the dead end composite insulators experience significantly higher electrical stress when compared to their suspension counterpart. It was also concluded that this difference gets more prominent as the system voltage increases. A comparison made between electric field distribution along composite insulators used in single and double dead end structures suggested that the electric stress experienced by the single dead end composite insulators is relatively higher when compared to double dead end composite insulators.
ContributorsDoshi, Tanushri (Author) / Gorur, Ravi S (Thesis advisor) / Vittal, Vijay (Committee member) / Farmer, Richard (Committee member) / Arizona State University (Publisher)
Created2010
149514-Thumbnail Image.png
Description
Composite insulators on overhead lines are frequently subjected to corona discharges due to increased electric field intensities under various conditions. These discharges can cause localized heating on the surface and affect the hydrophobicity of the insulator. A study has been undertaken to quantify and evaluate the thermal degradation that composite

Composite insulators on overhead lines are frequently subjected to corona discharges due to increased electric field intensities under various conditions. These discharges can cause localized heating on the surface and affect the hydrophobicity of the insulator. A study has been undertaken to quantify and evaluate the thermal degradation that composite insulation is subjected to from corona discharges. This has been conducted primarily at the power frequency (60 Hz) and at the low frequency range (37 kHz). Point to plane corona discharge experiments have been performed in the laboratory at both the frequencies and varying levels of thermal degradation has been observed. The amplitude and the frequency of current spikes have been recorded at different voltage levels. A temperature model based on the amplitude and the frequency of current data has been formulated to calculate the maximum temperature attained due to these discharges. Visual thermal degradation has been found to set in at a low frequency range while there is no visual degradation observed at power frequency even when exposed to discharges for relatively much longer periods of time. However, microscopic experiments have been conducted which revealed degradation on the surface at 60 Hz. It has also been found that temperatures in excess of 300 Celsius have been obtained at 37 kHz. This corroborates the thermo gravimetric analysis data that proves thermal degradation in silicone rubber samples at temperatures greater than 300 Celsius. Using the above model, the maximum temperature rise can be evaluated due to discharges occurring on high voltage insulation. This model has also been used to calculate the temperature rise on medium voltage distribution equipment such as composite bushings and stand-off plugs. The samples were subjected to standard partial discharge tests and the corresponding discharge magnitudes have been recorded. The samples passed the tests and the corresponding temperatures plotted have been found to be within thermal limits of the respective insulation used on the samples. The experimental results concur with the theoretical model. A knowledge of the maximum temperatures attained due to these discharges can help in design of insulation with better thermal properties.
ContributorsSangaraju Venkateshwara, Pradeep Varma (Author) / Gorur, Ravi S (Thesis advisor) / Farmer, Richard (Committee member) / Vittal, Vijay (Committee member) / Arizona State University (Publisher)
Created2010
189203-Thumbnail Image.png
Description
Both molecular structure of macromolecular materials and subsequent processing of these materials dictate resulting material properties. In this work novel synthetic strategies combined with detailed analytical methodology reveal fundamental structure-processing-property relationships in thermoplastic polyesters, thermoplastic polyurethanes, covalently crosslinked acetal functionalized networks, and small molecule surfactants. 4,4’ dimethyloxybisbenzoate afforded a series

Both molecular structure of macromolecular materials and subsequent processing of these materials dictate resulting material properties. In this work novel synthetic strategies combined with detailed analytical methodology reveal fundamental structure-processing-property relationships in thermoplastic polyesters, thermoplastic polyurethanes, covalently crosslinked acetal functionalized networks, and small molecule surfactants. 4,4’ dimethyloxybisbenzoate afforded a series of novel polyester structures, and the incorporation of this monomer both increased the Tg and decreased the crystallinity in cyclohexane dimethanol based polyesters. Solubility and dynamic light scattering experiments combined with oscillatory rheology techniques provided methodology to validate polyurethane extrusion in commercial polyurethanes. Acid catalyzed hydroxyl addition to vinyl ethers provided two families of acetal functionalized poly(ethylene glycol hydrogels). Stoichiometric control of binary thiol-acrylate polymerizations afforded hydrogels with both tunable mechanical properties and predictable degradation profiles. Following this work, a photoacid generator catalyzed cationic catalysis provided acetal functionalized organogels whose mechanical properties were predicted by excess vinyl ether monomers which underwent cationic polymerization under the same reaction conditions that yielded acetal functionalization. Time resolved FT-IR spectroscopy provided new understanding in hydroxyl vinyl ether reactions, where both hydroxyl addition to a vinyl ether and vinyl ether cationic polymerization occur concurrently. This work inspired research into new reactive systems for photobase generator applications. However, current photobase generator technologies proved incompatible for carbon-Michael reactions between acetoacetate and acrylate functionalities as a result of uncontrollable acrylate free radical polymerization. The fundamental knowledge and synthetic strategies afforded by these investigations were applied to small molecule surfactant systems for fire-fighting applications. Triethylsilyl-containing zwitterionic and cationic surfactants displayed surface tensions lower than hydrocarbon surfactants, but larger than siloxane-containing surfactants. For the first time, oscillatory rheology and polarized optical light imagine rheology highlighted shear-induced micelle alignment in triethylsilyl surfactants, which provided more stable foams than zwitterionic analogues. The knowledge gained from these investigations provided fundamental structure-processing-property relationships in small molecule surfactant solutions applied as fire-fighting foams. This discovery regarding the effect of self-assembled structures in foam solutions informs the design and analysis of next generation surfactants to replace fluorocarbon surfactants in fire-fighting foam applications.
ContributorsBrown, James Robert (Author) / Long, Timothy E (Thesis advisor) / Bortner, Michael J (Committee member) / Biegasiewicz, Kyle F (Committee member) / Jin, Kailong (Committee member) / Arizona State University (Publisher)