Matching Items (3)
Filtering by

Clear all filters

150596-Thumbnail Image.png
Description
Advances in miniaturized sensors and wireless technologies have enabled mobile health systems for efficient healthcare. A mobile health system assists the physician to monitor the patient's progress remotely and provide quick feedbacks and suggestions in case of emergencies, which reduces the cost of healthcare without the expense of hospitalization. This

Advances in miniaturized sensors and wireless technologies have enabled mobile health systems for efficient healthcare. A mobile health system assists the physician to monitor the patient's progress remotely and provide quick feedbacks and suggestions in case of emergencies, which reduces the cost of healthcare without the expense of hospitalization. This work involves development of an innovative mobile health system with adaptive biofeedback mechanism and demonstrates the importance of biofeedback in accurate measurements of physiological parameters to facilitate the diagnosis in mobile health systems. Resting Metabolic Rate (RMR) assessment, a key aspect in the treatment of diet related health problems is considered as a model to demonstrate the importance of adaptive biofeedback in mobile health. A breathing biofeedback mechanism has been implemented with digital signal processing techniques for real-time visual and musical guidance to accurately measure the RMR. The effects of adaptive biofeedback with musical and visual guidance were assessed on 22 healthy subjects (12 men, 10 women). Eight RMR measurements were taken for each subject on different days under same conditions. It was observed the subjects unconsciously followed breathing biofeedback, yielding consistent and accurate measurements for the diagnosis. The coefficient of variation of the measured metabolic parameters decreased significantly (p < 0.05) for 20 subjects out of 22 subjects.
ContributorsKrishnan, Ranganath (Author) / Tao, Nongjian (Thesis advisor) / Forzani, Erica (Committee member) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2012
161783-Thumbnail Image.png
Description
Energy Expenditure (EE), a key diagnostic measurement for treatment of obesity, is measured via indirect calorimetry method through breath biomarkers of CO2 production and/or O2 consumption rates (VCO2 and/or VO2, respectively). Current technologies are limited due to prevailing designs requiring wearable facial accessories that present accuracy, precision, and usability concerns

Energy Expenditure (EE), a key diagnostic measurement for treatment of obesity, is measured via indirect calorimetry method through breath biomarkers of CO2 production and/or O2 consumption rates (VCO2 and/or VO2, respectively). Current technologies are limited due to prevailing designs requiring wearable facial accessories that present accuracy, precision, and usability concerns with regards to free living measurement. A novel medical device and smart home system, named Smart Pad, has been developed, with the capability of energy expenditure assessment via VCO2 measured from a room’s CO2 concentration. The system has 3 distinct capabilities: contactless EE measurement, air quality optimization via actuation of room ventilation, and efficiency optimization via ventilation actuation of only human-occupied environments. The Smart Pad shows accuracy of 90% for 14-19 minutes of resting measurement and accuracy of 90% for 4.8-7.0 minutes of exercise measurement after calibrating for air exchange rate (λ [hour-1]) using a reference method. Without reference instrument calibration, the Smart Pad system shows average accuracy of nearly 100% with correlations of Y=1.02X, R=0.761 for high resolution measurements and Y=1.06X, R=0.937 for averaged measurements over 50-60 minutes. In addition, the Smart Pad validation for contactless EE measurement has been performed in different environments, including a vehicle, medical office, a private office, and an ambulatory enclosure with rooms, ranging in volume from 3.1 m3 to 18.8m3. It was concluded that contactless EE measurements can be accurately performed in all tested scenarios with both low and high air exchange environments with λ ranging from 1.5 Hours-1 to 10.0 Hours -1. The system represents a new way to assess EE of individuals under free-living conditions in an unobstructive, passive, and accurate manner, and it is comparable or better in single breath gas measurement accuracy (with comparisons sourced from FDA data) than other medical devices (e.g. Vyntus CPXTM, MasterScreen CPXTM, Oxycon ProTM, and MedGemTM) which were 510(k) cleared by the FDA for prescription use in metabolic/cardiopulmonary diagnostics.
ContributorsSprowls, Mark (Author) / Forzani, Erica (Thesis advisor) / Destaillats, Hugo (Committee member) / Kulick, Doina (Committee member) / Nikkhah, Mehdi (Committee member) / Raupp, Gregory (Committee member) / Arizona State University (Publisher)
Created2021
165579-Thumbnail Image.png
Description

Energy Expenditure (EE) (kcal/day) is a key parameter used to guide obesity treatment, and it is often measured from CO2 production, VCO2 (mL/min), and/or O2 consumption, VO2 (mL/min) through the principles of indirect calorimetry. Current EE measurement technologies are limited due to the requirement of wearable facial accessories, which can

Energy Expenditure (EE) (kcal/day) is a key parameter used to guide obesity treatment, and it is often measured from CO2 production, VCO2 (mL/min), and/or O2 consumption, VO2 (mL/min) through the principles of indirect calorimetry. Current EE measurement technologies are limited due to the requirement of wearable facial accessories, which can introduce errors as measurements are not taken under free-living conditions. A novel contactless system, the SmartPad, which measures EE via VCO2 from a room’s ambient CO2 concentration transients was evaluated. First, SmartPad accuracy was validated by comparing the SmartPad’s EE and VCO2 measurements with the measurements of a reference instrument, the MGC Ultima CPXTM, in a cross-sectional study consisting of 20 subjects. A high correlation between the SmartPad’s EE and VCO2 measurements and the MGC Ultima CPX’s EE and VCO2 measurements was found, and the Bland-Altman plots contained a low mean bias for EE and VCO2 measurements. Thus, the SmartPad was validated as being accurate for VCO2 and EE measurements. Next, resting EE (REE) and exercise VCO2 measurements were recorded using the SmartPad and the MGC Ultima CPXTM at different operating CO2 threshold ranges to investigate the influence of measurement duration on system accuracy in an effort to optimize the SmartPad system. The SmartPad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using a known room’s air exchange rate. Additionally, the SmartPad was validated by accurately measuring subjects’ REE across a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m^2) with REEs ranging from ~1200 to ~3000 kcal/day. Lastly, the SmartPad has been used to assess the physical fitness of subjects via the “Contactless Thermodynamic Efficiency Test” (CTET).

ContributorsVictor, Shaun (Author) / Forzani, Erica (Thesis director) / Wang, Shaopeng (Committee member) / Barrett, The Honors College (Contributor) / Watts College of Public Service & Community Solut (Contributor) / Harrington Bioengineering Program (Contributor)
Created2022-05