Filtering by
- All Subjects: Biomedical Engineering
- Creators: Stabenfeldt, Sarah
- Resource Type: Text
Polymeric nanoparticles (NP) consisting of Poly Lactic-co-lactic acid - methyl polyethylene glycol (PLLA-mPEG) or Poly Lactic-co-Glycolic Acid (PLGA) are an emerging field of study for therapeutic and diagnostic applications. NPs have a variety of tunable physical characteristics like size, morphology, and surface topography. They can be loaded with therapeutic and/or diagnostic agents, either on the surface or within the core. NP size is an important characteristic as it directly impacts clearance and where the particles can travel and bind in the body. To that end, the typical target size for NPs is 30-200 nm for the majority of applications. Fabricating NPs using the typical techniques such as drop emulsion, microfluidics, or traditional nanoprecipitation can be expensive and may not yield the appropriate particle size. Therefore, a need has emerged for low-cost fabrication methods that allow customization of NP physical characteristics with high reproducibility. In this study we manufactured a low-cost (<$210), open-source syringe pump that can be used in nanoprecipitation. A design of experiments was utilized to find the relationship between the independent variables: polymer concentration (mg/mL), agitation rate of aqueous solution (rpm), and injection rate of the polymer solution (mL/min) and the dependent variables: size (nm), zeta potential, and polydispersity index (PDI). The quarter factorial design consisted of 4 experiments, each of which was manufactured in batches of three. Each sample of each batch was measured three times via dynamic light scattering. The particles were made with PLLA-mPEG dissolved in a 50% dichloromethane and 50% acetone solution. The polymer solution was dispensed into the aqueous solution containing 0.3% polyvinyl alcohol (PVA). Data suggests that none of the factors had a statistically significant effect on NP size. However, all interactions and relationships showed that there was a negative correlation between the above defined input parameters and the NP size. The NP sizes ranged from 276.144 ± 14.710 nm at the largest to 185.611 ± 15.634 nm at the smallest. In conclusion, the low-cost syringe pump nanoprecipitation method can achieve small sizes like the ones reported with drop emulsion or microfluidics. While there are trends suggesting predictable tuning of physical characteristics, significant control over the customization has not yet been achieved.
In the past decade, numerous methods have been developed to analyze in-vivo calcium imaging data that involves complex techniques such as overlapping signals segregation and motion artifact correction. The hypothesis used to detect calcium signal is the spatiotemporal sparsity of calcium signal, and these methods are unable to identify the passive cells that are not actively firing during the time frame in the video. Statistics regarding the percentage of cells in each frame of view can be critical for the analysis of calcium imaging data for human induced pluripotent stem cells derived neurons and astrocytes.
The objective of this research is to develop a simple and efficient semi-automated pipeline for analysis of in-vitro calcium imaging data. The region of interest (ROI) based image segmentation is used to extract the data regarding intensity fluctuation caused by calcium concentration changes in each cell. It is achieved by using two approaches: basic image segmentation approach and a machine learning approach. The intensity data is evaluated using a custom-made MATLAB that generates statistical information and graphical representation of the number of spiking cells in each field of view, the number of spikes per cell and spike height.