Matching Items (5)
Filtering by

Clear all filters

149765-Thumbnail Image.png
Description
The goal of the study was twofold: (i) to investigate the synthesis of hematite-impregnated granular activated carbon (Fe-GAC) by hydrolysis of Fe (III) and (ii) to assess the effectiveness of the fabricated media in removal of arsenic from water. Fe-GAC was synthesized by hydrolysis of Fe(III) salts under two Fe

The goal of the study was twofold: (i) to investigate the synthesis of hematite-impregnated granular activated carbon (Fe-GAC) by hydrolysis of Fe (III) and (ii) to assess the effectiveness of the fabricated media in removal of arsenic from water. Fe-GAC was synthesized by hydrolysis of Fe(III) salts under two Fe (III) initial dosages (0.5M and 2M) and two hydrolysis periods (24 hrs and 72 hrs). The iron content of the fabricated Fe-GAC media ranged from 0.9% to 4.4% Fe/g of the dry media. Pseudo-equilibrium batch test data at pH = 7.7±0.2 in 1mM NaHCO3 buffered ultrapure water and challenge groundwater representative of the Arizona Mexico border region were fitted to a Freundlich isotherm model. The findings suggested that the arsenic adsorption capacity of the metal (hydr)oxide modified GAC media is primarily controlled by the surface area of the media, while the metal content exhibited lesser effect. The adsorption capacity of the media in the model Mexican groundwater matrix was significantly lower for all adsorbent media. Continuous flow short bed adsorber tests (SBA) demonstrated that the adsorption capacity for arsenic in the challenge groundwater was reduced by a factor of 3 to 4 as a result of the mass transport effects. When compared on metal basis, the iron (hydr)oxide modified media performed comparably well as existing commercial media for treatment of arsenic. On dry mass basis, the fabricated media in this study removed less arsenic than their commercial counterparts because the metal content of the commercial media was significantly higher.
ContributorsJain, Arti (Author) / Hristovski, Kiril (Thesis advisor) / Olson, Larry (Committee member) / Madar, David (Committee member) / Edwards, David (Committee member) / Arizona State University (Publisher)
Created2011
168780-Thumbnail Image.png
Description
Although anion exchange resins (AERs) have been implemented for a wide range of aqueous contaminants including notorious perfluoroalkyl acids (PFAAs) that are of human health concern, the potential benefits and underlying chemistry of weak-base (WB) AERs are overlooked. To fill these key gaps in the literature, this research evaluated the

Although anion exchange resins (AERs) have been implemented for a wide range of aqueous contaminants including notorious perfluoroalkyl acids (PFAAs) that are of human health concern, the potential benefits and underlying chemistry of weak-base (WB) AERs are overlooked. To fill these key gaps in the literature, this research evaluated the removal and regeneration efficiency of WB-AER (IRA 67 and IRA 96) with strong-base (SB) AER as the baseline. Batch equilibrium tests were first conducted for the removal of nitrate, sulfate, 3-phenylpropionic acid, and six legacy PFAAs with contrasting properties at different solution pH using polyacrylic and polystyrene chloride-form AERs. In ambient (pH 7) and acidic (pH 4) solutions, the polymer composition was the controlling factor followed by the length of alkyl chain of the resin while AER basicity did not influence the selectivity for the selected contaminants. WB resin had higher capacity than SB analogs based on quantitative analysis using isotherm model parameters. Batch and column adsorption experiments showed significantly greater removal of PFAAs by polystyrene than polyacrylic AERs regardless of resin basicity, with the order of decreasing polyacrylic resin selectivity of PFOS >> PFHxS ≈ PFOA > PFBS > PFHxA ≈ PFBA. The removal performance of WB-AER was reversible, declining drastically at basic conditions and gradually regained once below the pKa of the resin due to the pH-dependent nature of amine groups. This was not the case for IRA 96 (i.e., polystyrene) which exhibited high removal of PFAAs irrelevant of pH because of the nonpolar character of polystyrene matrix. The non-hydrophobic IRA 67 (i.e., polyacrylic) had a satisfactory regeneration using non-toxic salt-only solutions comprising 1% NaOH and 0.5% NaOH + 0.5% NaCl, while IRA 96 was only amenable to brine/methanol regeneration. Important caveats on the validity of isotherm modeling in batch adsorption tests were discussed. Results for batch and column experiments using chloride-form and free-base form WB-AER, respectively, provide insights for industrial applications.
ContributorsKassar, Christian (Author) / Boyer, Treavor H. (Thesis advisor) / Westerhoff, Paul K. (Committee member) / Conroy-Ben, Otakuye (Committee member) / Arizona State University (Publisher)
Created2022
156994-Thumbnail Image.png
Description
This dissertation critically evaluated methodologies and devices for assessing and protecting the health of human populations, with particular emphasis on groundwater remediation and the use of wastewater-based epidemiology (WBE) to inform population health. A meta-analysis and assessment of laboratory-scale treatability studies for removing chlorinated solvents from groundwater found that sediment

This dissertation critically evaluated methodologies and devices for assessing and protecting the health of human populations, with particular emphasis on groundwater remediation and the use of wastewater-based epidemiology (WBE) to inform population health. A meta-analysis and assessment of laboratory-scale treatability studies for removing chlorinated solvents from groundwater found that sediment microcosms operated as continuous-flow columns are preferable to batch bottles when seeking to emulate with high fidelity the complex conditions prevailing in the subsurface in contaminated aquifers (Chapter 2). Compared to monitoring at the field-scale, use of column microcosms also showed (i) improved chemical speciation, and (ii) qualitative predictability of field parameters (Chapter 3). Monitoring of glucocorticoid hormones in wastewater of a university campus showed (i) elevated stress levels particularly at the start of the semester, (ii) on weekdays relative to weekend days (p = 0.05) (161 ± 42 μg d-1 per person, 122 ± 54 μg d-1 per person; p ≤ 0.05), and (iii) a positive association between levels of stress hormones and nicotine (rs: 0.49) and caffeine (0.63) consumption in this student population (Chapter 4). Also, (i) alcohol consumption determined by WBE was in line with literature estimates for this young sub-population (11.3 ± 7.5 g d-1 per person vs. 10.1 ± 0.8 g d-1 per person), whereas caffeine and nicotine uses were below (114 ± 49 g d-1 per person, 178 ± 19 g d-1 per person; 627 ± 219 g d-1 per person, 927 ± 243 g d-1 per person). The introduction of a novel continuous in situ sampler to WBE brought noted benefits relative to traditional time-integrated sampling, including (i) a higher sample coverage (93% vs. 3%), (ii) an ability to captured short-term analyte pulses (e.g., heroin, fentanyl, norbuprenorphine, and methadone), and (iii) an overall higher mass capture for drugs of abuse like morphine, fentanyl, methamphetamine, amphetamine, and the opioid antagonist metabolite norbuprenorphine (p ≤ 0.01). Methods and devices developed in this work are poised to find applications in the remediation sector and in human health assessments.
ContributorsDriver, Erin Michelle (Author) / Halden, Rolf (Thesis advisor) / Conroy-Ben, Otakuye (Committee member) / Kavazanjian, Edward (Committee member) / Krajmalnik-Brown, Rosa (Committee member) / Arizona State University (Publisher)
Created2018
154169-Thumbnail Image.png
Description
Arsenic (As) is a naturally occurring element that poses a health risk when continually consumed at levels exceeding the Environmental Protection Agencies (EPA) maximum contaminant level (MCL) of 10 ppb. With the Arizona Department of Water Resources considering reliance on other sources of water other than just solely surface water,

Arsenic (As) is a naturally occurring element that poses a health risk when continually consumed at levels exceeding the Environmental Protection Agencies (EPA) maximum contaminant level (MCL) of 10 ppb. With the Arizona Department of Water Resources considering reliance on other sources of water other than just solely surface water, groundwater proves a reliable, supplemental source. The Salt River Project (SRP) wants to effectively treat their noncompliance groundwater sources to meet EPA compliance. Rapid small-scale column tests (RSSCTs) of two SRP controlled groundwater wells along the Eastern Canal and Consolidated Canal were designed to assist SRP in selection and future design of full-scale packed bed adsorbent media. Main concerns for column choice is effectiveness, design space at groundwater wells, and simplicity. Two adsorbent media types were tested for effective treatment of As to below the MCL: a synthetic iron oxide, Bayoxide E33, and a strong base anion exchange resin, SBG-1. Both media have high affinity toward As and prove effective at treating As from these groundwater sources. Bayoxide E33 RSSCT performance indicated that As treatment lasted to near 60,000 bed volumes (BV) in both water sources and still showed As adsorption extending past this operation ranging from several months to a year. SBG-1 RSSCT performance indicated As, treatment lasted to 500 BV, with the added benefit of being regenerated. At 5%, 13%, and 25% brine regeneration concentrations, regeneration showed that 5% brine is effective, yet would complicate overall design and footprint. Bayoxide E33 was selected as the best adsorbent media for SRP use in full-scale columns at groundwater wells due to its simplistic design and high efficiency.
ContributorsLesan, Dylan (Author) / Westerhoff, Paul (Thesis advisor) / Hristovski, Kiril (Committee member) / Fraser, Matthew (Committee member) / Arizona State University (Publisher)
Created2015
152804-Thumbnail Image.png
Description
Arsenic (As) and chromium (Cr) occur naturally in AZ surface and groundwaters, pose different health impacts, and exhibit different treatment efficacies. Hexavalent chromium (Cr(VI)) has newly recognized human health concerns, and State and Federal agencies are evaluating a low Cr(VI)-specific maximum contaminant level (MCL) for drinking water. Occurrence of Cr

Arsenic (As) and chromium (Cr) occur naturally in AZ surface and groundwaters, pose different health impacts, and exhibit different treatment efficacies. Hexavalent chromium (Cr(VI)) has newly recognized human health concerns, and State and Federal agencies are evaluating a low Cr(VI)-specific maximum contaminant level (MCL) for drinking water. Occurrence of Cr and As in municipal drinking waters and industrial cooling tower waters was quantified by grab samples and compared with sampling results obtained from a new passive sampler developed specifically for Cr(VI). Cr(VI) and As concentrations in groundwater used for cooling tower make-up water concentrations were ~3 ppb and ~4 ppb, respectively, and were concentrated significantly in blowdown water (~20 ppb and ~40 ppb). Based upon pending Cr(VI), As, and other metal regulations, these blowdown waters will need routine monitoring and treatment. Cr(VI) concentrations in a water treatment plant (WTP) raw and finished water samples varied from 0.5 and 2 ppb for grab samples collected every 4 hours for 7 consecutive days using an ISCO sampler. The development of an ion exchange (IX) based passive sampler was validated in the field at the WTP and yielded an average exposure within 1 standard deviation of ISCO sampler grab data. Sampling at both the WTP and cooling towers suggested sources of Cr(III) from treatment chemicals or wood preservatives may exist. Since both facilities use chlorine oxidants, I quantified the apparent (pH=5) second-order rate constant for aqueous chlorine (HOCl/OCl-) with Cr(III) to form Cr(VI) as 0.7 M-1s-1. Under typical conditions (2 ppb Cr(III) ; 2 mg/L Cl2) the half-life for the conversion of Cr(III) to the more toxic form Cr(VI) is 4.7 hours. The occurrence studies in AZ and CA show the Cr(VI) and As treatment of groundwaters will be required to meet stringent Cr(VI) regulations. IX technologies, both strong base anion (SBA) and weak base anion (WBA) resin types were screened (and compared) for Cr removal. The SBA IX process for As removal was optimized by utilizing a reactive iron coagulation and filtration (RCF) process to treat spent IX brine, which was then reused to for SBA resin regeneration.
ContributorsBowen, Alexandra (Author) / Paul, Westerhoff K. (Thesis advisor) / Hristovski, Kiril (Committee member) / Halden, Rolf (Committee member) / Arizona State University (Publisher)
Created2014