Description
Vapor intrusion (VI), can pose health risks to building occupants. Assessment and mitigation at VI impacted sites have been guided by a site conceptual model (SCM) in which vapors originate from subsurface sources, diffuse through soil matrix and enter into

Vapor intrusion (VI), can pose health risks to building occupants. Assessment and mitigation at VI impacted sites have been guided by a site conceptual model (SCM) in which vapors originate from subsurface sources, diffuse through soil matrix and enter into a building by gas flow across foundation cracks. Alternative VI pathways and groundwater table fluctuations are not often considered.

Alternative VI pathways, involving vapor transport along sewer lines and other subsurface infrastructure, have recently been found to be significant contributors to VI impacts at some sites. This study evaluated approaches for identifying and characterizing the significance of alternative VI pathways and assessed the effectiveness of conventional mitigation at a site with an alternative VI pathway that can be manipulated to be on or off. The alternative pathway could not be identified using conventional pathway assessment procedures and can only be discovered under controlled pressure method (CPM) conditions. Measured emission rates were two orders of magnitude greater than screening model estimates and sub-foundation vertical soil gas profiles changed and were no longer consistent with the conventional VI conceptual model when the CPM test was conducted. The pipe flow VI pathway reduced the vacuum performance of the sub-slab depressurization (SSD) VI mitigation system, but the SSD system still provided sufficient protection to the house.

The relationship between groundwater table fluctuations and subsurface vapor emissions and transport is examined using multi-year data from the field site, and is studied in the laboratory. In addition, a broader range of conditions is examined through use of modeling validated with the experimental data. The results indicate that fluctuating groundwater tables will lead to amplified volatile organic chemical (VOC) emissions from groundwater to soil surface relative to steady water table elevation, however, the magnitude of this amplification is less concerned when long-term water fluctuation present. No clear correlations were found between VOC emissions and water table changes at the study site where annual water table fluctuations of about 0.3 m existed. Significant VOC emission amplifications by water table fluctuation would be expected under shallow groundwater conditions according to model analysis results.
Reuse Permissions
  • Downloads
    pdf (16.5 MB)

    Details

    Title
    • Vapor intrusion at a site with an alternative pathway and a fluctuating groundwater table
    Contributors
    Date Created
    2015
    Resource Type
  • Text
  • Collections this item is in
    Note
    • Partial requirement for: Ph.D., Arizona State University, 2015
      Note type
      thesis
    • Includes bibliographical references (pages 223-229)
      Note type
      bibliography
    • Field of study: Civil and environmental engineering

    Citation and reuse

    Statement of Responsibility

    by Yuanming Guo