Description

A 4-phase, quasi-current-mode hysteretic buck converter with digital frequency synchronization, online comparator offset-calibration and digital current sharing control is presented. The switching frequency of the hysteretic converter is digitally synchronized

A 4-phase, quasi-current-mode hysteretic buck converter with digital frequency synchronization, online comparator offset-calibration and digital current sharing control is presented. The switching frequency of the hysteretic converter is digitally synchronized to the input clock reference with less than ±1.5% error in the switching frequency range of 3-9.5MHz. The online offset calibration cancels the input-referred offset of the hysteretic comparator and enables ±1.1% voltage regulation accuracy.

Reuse Permissions
  • 3.71 MB application/pdf

    Download count: 0

    Details

    Contributors
    Date Created
    • 2017
    Resource Type
  • Text
  • Collections this item is in
    Note
    • Doctoral Dissertation Electrical Engineering 2017

    Machine-readable links