Technologies used in corrective scoliosis surgery do not provide accurate, validated measurements of applied loading on the spine. Proposing a solution to optimize intra-operative load sensing to enhance surgical outcomes, mechanical factors of a capacitive load sensor are examined. Using ASTM D3574-17, experimental methods were performed to verify material homogeneity

Technologies used in corrective scoliosis surgery do not provide accurate, validated measurements of applied loading on the spine. Proposing a solution to optimize intra-operative load sensing to enhance surgical outcomes, mechanical factors of a capacitive load sensor are examined. Using ASTM D3574-17, experimental methods were performed to verify material homogeneity and validity, to identify critical factors in maximizing compressive strength, and to understand preliminary fatigue behavior for reliability measures. In leveraging the Design of Experiment (DOE) methodology to decrease device variability, the mechanical factors explored were: sensor thickness, diameter ratio of conductive foam, density, and surface hardness. Multiple iterations DOEs identified high thickness and low diameter ratios as significant factors which increase the output response of compressive strength. After identifying the optimal factor combination for the sensor it was found that the maximum experimental load range was 15.57N-16.9lbf. Fatigue testing was then performed on the highest performing factor combination group from the compression results. From the two rounds that were tested on sensor specimen, no significant difference was found between the two groups' rates of changes in thickness per compression. Each round of foam testing resulted in similar thickness values, which suggests that the sensor has potential to perform consistently during a 6-8 hour surgery if a material with improved elasticity and mechanical strength is used. Thus, the experimental procedures fulfill proof-of-concept tests to indicate feasibility of compressive strength and reliability of the sensor's mechanical features. Future experimentations will involve using a different dielectric material in place of the foam, such as a conductive thermoset or thermoplastic elastomer. Additional levels for each factor will be test to test the behavior of the material to yield a higher compressive strength and certainty of reliability. Overall, this study was useful in identifying significant factors for achieving compressive strength, while also providing evidence of the device's potential for reliability during scoliosis surgeries.
ContributorsWieser, Megan Marie (Author) / LaBelle, Jeffrey (Thesis director) / Newcomb, Anna (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2018-05
133053-Thumbnail Image.png
Description
A point of care glucose sensor using electrochemical impedance spectroscopy (EIS) with a glutaraldehyde-linked enzyme shows promise as an effective biosensor platform. This report details the characterization of various factors on optimal binding frequency (OBF) and sensor performance to better prepare the sensor for future experimentation. Utilizing a screen printed

A point of care glucose sensor using electrochemical impedance spectroscopy (EIS) with a glutaraldehyde-linked enzyme shows promise as an effective biosensor platform. This report details the characterization of various factors on optimal binding frequency (OBF) and sensor performance to better prepare the sensor for future experimentation. Utilizing a screen printed carbon electrode, the necessary amount of glucose oxidase was determined to be 10 mg/mL. Binding time trials ranging from 1-3 minutes demonstrated that 1.5 minutes was the optimal binding time. This timeframe produced the strongest impedance response at each glucose concentration. Using this enzyme concentration and binding time, the native OBF of the biosensor was found to be 1.18 Hz using vector analysis. Temperature testing showed little change in OBF in sensors exposed to 4 \u00B0C through 43.3 \u00B0C. Only exposure to 60 \u00B0C resulted in rapid OBF change which was likely due to glucose oxidase becoming denatured. Humidity tests showed little change in OBF and sensor performance between sensors prepared at the humidities of 7.5%, 10.625% and 16.5% humidity. Alternatively, solutions containing common interference molecules such as uric acid, acetaminophen, and ascorbic acid resulted in a highly shifted OBF and drastically reduced signal.
ContributorsMatloff, Daniel (Co-author) / Khanwalker, Mukund (Co-author) / Johns, Jared (Co-author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Lin, Chi (Committee member) / Dean, W.P. Carey School of Business (Contributor) / School of Life Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2018-12
134280-Thumbnail Image.png
Description
As of today, there does not exist a cheap diagnostic for lactate for use in trauma centers. $671 billion are spent on trauma accidents and emergency rooms, with money focused on treatments such as YSI and ELISA, costing $1500 and $200, respectively. Gold disk electrodes were used to immobilize lactate

As of today, there does not exist a cheap diagnostic for lactate for use in trauma centers. $671 billion are spent on trauma accidents and emergency rooms, with money focused on treatments such as YSI and ELISA, costing $1500 and $200, respectively. Gold disk electrodes were used to immobilize lactate dehydrogenase and glucose oxidase, with electrochemical impedance spectroscopy (EIS) used as the method for detection. Two lactate experimental runs were completed with data detailing a linear model and positive correlation for imaginary impedance and concentration, and one glucose experimental run was completed proving that a continuous system can be completed accounting for reaction and consumption using EIS, a process previously not done before.
ContributorsEltohamy, Omar Khaled (Author) / LaBelle, Jeffrey (Thesis director) / Lin, Chi-En (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2017-05
133226-Thumbnail Image.png
Description
Insulin is an essential peptide hormone that aides in the metabolism of glucose by allowing the cells to uptake glucose. Exogenous insulin is often prescribed to patients in order to help manage their diabetes. Recent research has indicated that prescription insulin is not at the labeled concentration when the prescription

Insulin is an essential peptide hormone that aides in the metabolism of glucose by allowing the cells to uptake glucose. Exogenous insulin is often prescribed to patients in order to help manage their diabetes. Recent research has indicated that prescription insulin is not at the labeled concentration when the prescription is filled by the patient. This decrease in concentration from when the insulin is manufactured to when it reaches the pharmacy is likely due to the insulin denaturing and aggregating. Dynamic light scattering is a useful and accurate method to determine the hydrodynamic radius of a solute and can be used to measure the hydrodynamic radius of insulin which will thus determine the aggregation of the sample since the more aggregated it is, the larger the hydrodynamic radius will be. By testing the effect of pH, concentration, temperature, and time on insulin samples, the optimal storage conditions can be determined in order to ensure researchers and patients are not using aggregated insulin. No conclusive relationship was found between any variable and sample diameter, but several trends were identified. Temperature, pH, and time in solution are all factors that could impact the aggregation, and therefore activity, of insulin. However, concentration did not show any trend regarding aggregation. Determining the relationships between these variables could allow for the identification of ideal storage conditions for researchers. Additionally, it can be used to identify shortcomings in the insulin supply chain.
ContributorsMorrow, Blake (Author) / LaBelle, Jeffrey (Thesis director) / Lin, Chi-En (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2018-05
134788-Thumbnail Image.png
Description
Concussions and traumatic brain injuries are mechanical events which can derive from no specific activity or event. However, these injuries occur often during athletic and sporting events but many athletes experiencing these symptoms go undiagnosed and continue playing without proper medical attention. The current gold standard for diagnosing athletes with

Concussions and traumatic brain injuries are mechanical events which can derive from no specific activity or event. However, these injuries occur often during athletic and sporting events but many athletes experiencing these symptoms go undiagnosed and continue playing without proper medical attention. The current gold standard for diagnosing athletes with concussions is to have medical professionals on the sidelines of events to perform qualitative standardized assessments which may not be performed frequently enough and are not specialized for each athlete. The purpose of this report is to discuss a study sanctioned by Arizona State University's Project HoneyBee and additional affiliations to validate a third-party mouth guard device product to recognize and detect force impacts blown to an athlete's head during athletic activity. Current technology in health monitoring medical devices can allow users to apply this device as an additional safety mechanism for early concussion awareness and diagnosis. This report includes the materials and methods used for experimentation, the discussion of its results, and the complications which occurred and areas for improvement during the preliminary efforts of this project. Participants in the study were five non-varsity ASU Wrestling athletes who volunteered to wear a third-party mouth guard device during sparring contact at practice. Following a needed calibration period for the devices, results were recorded both through visual observation and with the mouth guard devices using an accelerometer and gyroscope. This study provided a sound understanding for the operation and functionality of the mouth guard devices. The mouth guard devices have the capability to provide fundamental avenues of research for future investigations.
ContributorsTielke, Austin Wyatt (Author) / Ross, Heather (Thesis director) / LaBelle, Jeffrey (Committee member) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2016-12
153581-Thumbnail Image.png
Description
The advent of medical imaging has enabled significant advances in pre-procedural planning, allowing cardiovascular anatomy to be visualized noninvasively before a procedure. However, absolute scale and tactile information are not conveyed in traditional pre-procedural planning based on images alone. This information deficit fails to completely prepare clinicians for complex heart

The advent of medical imaging has enabled significant advances in pre-procedural planning, allowing cardiovascular anatomy to be visualized noninvasively before a procedure. However, absolute scale and tactile information are not conveyed in traditional pre-procedural planning based on images alone. This information deficit fails to completely prepare clinicians for complex heart repair, where surgeons must consider the varied presentations of cardiac morphology and malformations. Three-dimensional (3D) visualization and 3D printing provide a mechanism to construct patient-specific, scale models of cardiovascular anatomy that surgeons and interventionalists can examine prior to a procedure. In addition, the same patient-specific models provide a valuable resource for educating future medical professionals. Instead of looking at idealized images on a computer screen or pages from medical textbooks, medical students can review a life-like model of patient anatomy.



In cases where surgical repair is insufficient to return the heart to normal function, a patient may proceed to advanced heart failure, and a heart transplant may be required. Unfortunately, a finite number of available donor hearts are available. A mechanical circulatory support (MCS) device can be used to bridge the time between heart failure and reception of a donor heart. These MCS devices are typically constructed for the adult population. Accordingly, the size associated to the device is a limiting factor for small adults or pediatric patients who often have smaller thoracic measurements. While current eligibility criteria are based on correlative measurements, the aforementioned 3D visualization capabilities can be leveraged to accomplish patient-specific fit analysis.

The main objectives of the work presented in this dissertation were 1) to develop and evaluate an optimized process for 3D printing cardiovascular anatomy for surgical planning and medical education and 2) to develop and evaluate computational tools to assess MCS device fit in specific patients. The evaluations for objectives 1 and 2 were completed with a collection of qualitative and quantitative validations. These validations include case studies to illustrate meaningful, qualitative results as well as quantitative results from surgical outcomes. The latter results present the first quantitative supporting evidence, beyond anecdotal case studies, regarding the efficacy of 3D printing for pre-procedural planning; this data is suitable as pilot data for clinical trials. The products of this work were used to plan 200 cardiovascular procedures (including 79 cardiothoracic surgeries at Phoenix Children's Hospital), via 3D printed heart models and assess MCS device fit in 29 patients across 6 countries.
ContributorsRyan, Justin Robert (Author) / Frakes, David (Thesis advisor) / Collins, Daniel (Committee member) / LaBelle, Jeffrey (Committee member) / Pizziconi, Vincent (Committee member) / Pophal, Stephen (Committee member) / Arizona State University (Publisher)
Created2015
154931-Thumbnail Image.png
Description
This thesis dissertation presents design of portable low power Electrochemical Impedance Spectroscopy (EIS) system which can be used for biomedical applications such as tear diagnosis, blood diagnosis, or any other body-fluid diagnosis. Two design methodologies are explained in this dissertation (a) a discrete component-based portable low-power EIS system and (b)

This thesis dissertation presents design of portable low power Electrochemical Impedance Spectroscopy (EIS) system which can be used for biomedical applications such as tear diagnosis, blood diagnosis, or any other body-fluid diagnosis. Two design methodologies are explained in this dissertation (a) a discrete component-based portable low-power EIS system and (b) an integrated CMOS-based portable low-power EIS system. Both EIS systems were tested in a laboratory environment and the characterization results are compared. The advantages and disadvantages of the integrated EIS system relative to the discrete component-based EIS system are presented including experimental data. The specifications of both EIS systems are compared with commercially available non-portable EIS workstations. These designed EIS systems are handheld and very low-cost relative to the currently available commercial EIS workstations.
ContributorsGhorband, Vishal (Author) / Blain Christen, Jennifer (Thesis advisor) / Song, Hongjiang (Committee member) / LaBelle, Jeffrey (Committee member) / Arizona State University (Publisher)
Created2016
155565-Thumbnail Image.png
Description
The American Diabetes Association reports that diabetes costs $322 billion annually and affects 29.1 million Americans. The high out-of-pocket cost of managing diabetes can lead to noncompliance causing serious and expensive complications. There is a large market potential for a more cost-effective alternative to the current market standard of screen-printed

The American Diabetes Association reports that diabetes costs $322 billion annually and affects 29.1 million Americans. The high out-of-pocket cost of managing diabetes can lead to noncompliance causing serious and expensive complications. There is a large market potential for a more cost-effective alternative to the current market standard of screen-printed self-monitoring blood glucose (SMBG) strips. Additive manufacturing, specifically 3D printing, is a developing field that is growing in popularity and functionality. 3D printers are now being used in a variety of applications from consumer goods to medical devices. Healthcare delivery will change as the availability of 3D printers expands into patient homes, which will create alternative and more cost-effective methods of monitoring and managing diseases, such as diabetes. 3D printing technology could transform this expensive industry. A 3D printed sensor was designed to have similar dimensions and features to the SMBG strips to comply with current manufacturing standards. To make the sensor electrically active, various conductive filaments were tested and the conductive graphene filament was determined to be the best material for the sensor. Experiments were conducted to determine the optimal print settings for printing this filament onto a mylar substrate, the industry standard. The reagents used include a mixture of a ferricyanide redox mediator and flavin adenine dinucleotide dependent glucose dehydrogenase. With these materials, each sensor only costs $0.40 to print and use. Before testing the 3D printed sensor, a suitable design, voltage range, and redox probe concentration were determined. Experiments demonstrated that this novel 3D printed sensor can accurately correlate current output to glucose concentration. It was verified that the sensor can accurately detect glucose levels from 25 mg/dL to 400 mg/dL, with an R2 correlation value as high as 0.97, which was critical as it covered hypoglycemic to hyperglycemic levels. This demonstrated that a 3D-printed sensor was created that had characteristics that are suitable for clinical use. This will allow diabetics to print their own test strips at home at a much lower cost compared to SMBG strips, which will reduce noncompliance due to the high cost of testing. In the future, this technology could be applied to additional biomarkers to measure and monitor other diseases.
ContributorsAdams, Anngela (Author) / LaBelle, Jeffrey (Thesis advisor) / Pizziconi, Vincent (Committee member) / Abbas, James (Committee member) / Arizona State University (Publisher)
Created2017
151306-Thumbnail Image.png
Description
Over the past fifty years, the development of sensors for biological applications has increased dramatically. This rapid growth can be attributed in part to the reduction in feature size, which the electronics industry has pioneered over the same period. The decrease in feature size has led to the production of

Over the past fifty years, the development of sensors for biological applications has increased dramatically. This rapid growth can be attributed in part to the reduction in feature size, which the electronics industry has pioneered over the same period. The decrease in feature size has led to the production of microscale sensors that are used for sensing applications, ranging from whole-body monitoring down to molecular sensing. Unfortunately, sensors are often developed without regard to how they will be integrated into biological systems. The complexities of integration are underappreciated. Integration involves more than simply making electrical connections. Interfacing microscale sensors with biological environments requires numerous considerations with respect to the creation of compatible packaging, the management of biological reagents, and the act of combining technologies with different dimensions and material properties. Recent advances in microfluidics, especially the proliferation of soft lithography manufacturing methods, have established the groundwork for creating systems that may solve many of the problems inherent to sensor-fluidic interaction. The adaptation of microelectronics manufacturing methods, such as Complementary Metal-Oxide-Semiconductor (CMOS) and Microelectromechanical Systems (MEMS) processes, allows the creation of a complete biological sensing system with integrated sensors and readout circuits. Combining these technologies is an obstacle to forming complete sensor systems. This dissertation presents new approaches for the design, fabrication, and integration of microscale sensors and microelectronics with microfluidics. The work addresses specific challenges, such as combining commercial manufacturing processes into biological systems and developing microscale sensors in these processes. This work is exemplified through a feedback-controlled microfluidic pH system to demonstrate the integration capabilities of microscale sensors for autonomous microenvironment control.
ContributorsWelch, David (Author) / Blain Christen, Jennifer (Thesis advisor) / Muthuswamy, Jitendran (Committee member) / Frakes, David (Committee member) / LaBelle, Jeffrey (Committee member) / Goryll, Michael (Committee member) / Arizona State University (Publisher)
Created2012
137648-Thumbnail Image.png
Description
Camp Hope is an organization dedicated to motivating children in foster care to pursue higher education. In this paper, the organization's founder applies the engineering design process to the problems currently facing Arizona's foster care system. What emerges is Camp Hope (i.e. the "product") and in turn a model by

Camp Hope is an organization dedicated to motivating children in foster care to pursue higher education. In this paper, the organization's founder applies the engineering design process to the problems currently facing Arizona's foster care system. What emerges is Camp Hope (i.e. the "product") and in turn a model by which it can be promulgated throughout the Phoenix metropolitan area and abroad. Prototype camps held abroad in Mexico, and at local group homes in Tempe, Arizona verify the initial user inputs with 68% of campers reporting new academic interests in pre/post camp surveys. Future work includes continued fine-tuning of the model through continued Arizona camps, and longer-term surveys tracking the development of children who participate in the program.
ContributorsSaez, Neil Alexander (Author) / LaBelle, Jeffrey (Thesis director) / Pizziconi, Vincent (Committee member) / Fitzgerald, Charles A. (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2013-05