151239-Thumbnail Image.png
Description
Biosensors offer excellent diagnostic methods through precise quantification of bodily fluid biomarkers and could fill an important niche in diagnostic screening. The long term goal of this research is the development of an impedance immunosensor for easy-to-use, rapid, sensitive and selective simultaneously multiplexed quantification of bodily fluid disease biomarkers. To

Biosensors offer excellent diagnostic methods through precise quantification of bodily fluid biomarkers and could fill an important niche in diagnostic screening. The long term goal of this research is the development of an impedance immunosensor for easy-to-use, rapid, sensitive and selective simultaneously multiplexed quantification of bodily fluid disease biomarkers. To test the hypothesis that various cytokines induce empirically determinable response frequencies when captured by printed circuit board (PCB) impedance immunosensor surface, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods were used to test PCB biosensors versus multiple cytokine biomarkers to determine limits of detection, background interaction and response at all sweep frequencies. Results indicated that sensors for cytokine Interleukin-12 (IL-12) detected their target over three decades of concentration and were tolerant to high levels of background protein. Further, the hypothesis that cytokine analytes may be rapidly detected via constant frequency impedance immunosensing without sacrificing undue sensitivity, CV, EIS, impedance-time (Zt) methods and modeling were used to test CHITM gold electrodes versus IL-12 over different lengths of time to determine limits of detection, detection time, frequency of response and consistent cross-platform sensor performance. Modeling and Zt studies indicate interrogation of the electrode with optimum frequency could be used for detection of different target concentrations within 90 seconds of sensor exposure and that interrogating the immunosensor with fixed, optimum frequency could be used for sensing target antigen. This informs usability of fixed-frequency impedance methods for biosensor research and particularly for clinical biosensor use. Finally, a multiplexing impedance immunosensor prototype for quantification of biomarkers in various body fluids was designed for increased automation of sample handling and testing. This enables variability due to exogenous factors and increased rapidity of assay with eased sensor fabrication. Methods were provided for simultaneous multiplexing through multisine perturbation of a sensor, and subsequent data processing. This demonstrated ways to observe multiple types of antibody-antigen affinity binding events in real time, reducing the number of sensors and target sample used in the detection and quantification of multiple biomarkers. These features would also improve the suitability of the sensor for clinical multiplex detection of disease biomarkers.
ContributorsFairchild, Aaron (Author) / La Belle, Jeffrey T (Thesis advisor) / Muthuswamy, Jitendran (Committee member) / Nagaraj, Vinay (Committee member) / Pizziconi, Vince (Committee member) / Vernon, Brent (Committee member) / Arizona State University (Publisher)
Created2012
151266-Thumbnail Image.png
Description
This dissertation provides a fundamental understanding of the properties of mesoporous carbon based materials and the utilization of those properties into different applications such as electrodes materials for super capacitors, adsorbents for water treatments and biosensors. The thickness of mesoporous carbon films on Si substrates are measured by Ellipsometry method

This dissertation provides a fundamental understanding of the properties of mesoporous carbon based materials and the utilization of those properties into different applications such as electrodes materials for super capacitors, adsorbents for water treatments and biosensors. The thickness of mesoporous carbon films on Si substrates are measured by Ellipsometry method and pore size distribution has been calculated by Kelvin equation based on toluene adsorption and desorption isotherms monitored by Ellipsometer. The addition of organometallics cobalt and vanalyl acetylacetonate in the synthesis precursor leads to the metal oxides in the carbon framework, which largely decreased the shrink of the framework during carbonization, resulting in an increase in the average pore size. In addition to the structural changes, the introduction of metal oxides into mesoporous carbon framework greatly enhances the electrochemical performance as a result of their pseudocapacitance. Also, after the addition of Co into the framework, the contraction of mesoporous powders decreased significantly and the capacitance increased prominently because of the solidification function of CoO nanoparticles. When carbon-cobalt composites are used as adsorbent, the adsorption capacity of dye pollutant in water is remarkably higher (90 mg/g) after adding Co than the mesoporous carbon powder (2 mg/g). Furthermore, the surface area and pore size of mesoporous composites can be greatly increased by addition of tetraethyl orthosilicate into the precursor with subsequent etching, which leads to a dramatic increase in the adsorption capacity from 90 mg/g up to 1151 mg/g. When used as electrode materials for amperometric biosensors, mesoporous carbons showed good sensitivity, selectivity and stability. And fluorine-free and low-cost poly (methacrylate)s have been developed as binders for screen printed biosensors. With using only 5wt% of poly (hydroxybutyl methacrylate), the glucose sensor maintained mechanical integrity and exhibited excellent sensitivity on detecting glucose level in whole rabbit blood. Furthermore, extremely high surface area mesoporous carbons have been synthesized by introducing inorganic Si precursor during self-assembly, which effectively determined norepinephrine at very low concentrations.
ContributorsDai, Mingzhi (Author) / Vogt, Bryan D (Thesis advisor) / La Belle, Jeffrey T (Committee member) / Dai, Lenore (Committee member) / Nielsen, David R (Committee member) / Torres, César I (Committee member) / Arizona State University (Publisher)
Created2012
157476-Thumbnail Image.png
Description
Medulloblastoma is the most common malignant pediatric brain cancer and is classified into four different subgroups based on genetic profiling: sonic hedgehog (SHH), WNT, Group 3 and 4. Changes in gene expression often alter the progression and development of cancers. One way to control gene expression is through the acetylation

Medulloblastoma is the most common malignant pediatric brain cancer and is classified into four different subgroups based on genetic profiling: sonic hedgehog (SHH), WNT, Group 3 and 4. Changes in gene expression often alter the progression and development of cancers. One way to control gene expression is through the acetylation and deacetylation of histones. More specifically in medulloblastoma SHH and Group 3, there is an increased deacetylation, and histone deacetylase inhibitors (HDACi) can be used to target this change. Not only can HDACi target increases in deacetylation, they are also known to induce cell cycle arrest and apoptosis. The combination of these factors has made HDACi a promising cancer therapeutic. Panobinostat, a hydrophobic, small molecule HDACi was recently identified as a potent molecule of interest for the treatment of medulloblastoma. Furthermore, panobinostat has already been FDA approved for treatment in multiple myeloma and is being explored in clinical trials against various solid tumors. The laboratory is interested in developing strategies to encapsulate panobinostat within nanoparticles composed of the biodegradable and biocompatible polymer poly(lactic acid)-poly(ethylene glycol) (PLA-PEG). Nanoparticles are formed by single emulsion, a process in which hydrophobic drugs can be trapped within the hydrophobic nanoparticle core. The goal was to determine if the molecular weight of the hydrophobic portion of the polymer, PLA, has an impact on loading of panobinostat in PLA-PEG nanoparticles. Nanoparticles formulated with PLA of varying molecular weight were characterized for loading, size, zeta potential, controlled release, and in vivo tolerability. The results of this work demonstrate that panobinostat loaded nanoparticles are optimally formulated with a 20:5kDa PLA-PEG, enabling loading of ~3.2 % w/w panobinostat within nanoparticles possessing an average diameter of 102 nm and surface charge of -8.04 mV. Panobinostat was released from nanoparticles in a potentially biphasic fashion over 72 hours. Nanoparticles were well tolerated by intrathecal injection, although a cell culture assay suggesting reduced bioactivity of encapsulated drug warrants further study. These experiments demonstrate that the molecular weight of PLA influences loading of panobinostat into PLA-PEG nanoparticles and provide basic characterization of nanoparticle properties to enable future in vivo evaluation.
ContributorsDharmaraj, Shruti (Author) / Sirianni, Rachael W. (Thesis advisor) / Stabenfeldt, Sarah E (Thesis advisor) / Vernon, Brent L (Committee member) / Arizona State University (Publisher)
Created2019
156620-Thumbnail Image.png
Description
Monitoring complex diseases and their comorbidities requires accurate and convenient measurements of multiple biomarkers. However, many state-of-the-art bioassays not only require complicated and time-consuming procedures, but also measure only one biomarker at a time. This noncomprehensive single-biomarker monitoring, as well as the cost and complexity of these bioassays advocate for

Monitoring complex diseases and their comorbidities requires accurate and convenient measurements of multiple biomarkers. However, many state-of-the-art bioassays not only require complicated and time-consuming procedures, but also measure only one biomarker at a time. This noncomprehensive single-biomarker monitoring, as well as the cost and complexity of these bioassays advocate for a simple, rapid multi-marker sensing platform suitable for point-of-care or self-monitoring settings. To address this need, diabetes mellitus was selected as the example complex disease, with dry eye disease and cardiovascular disease as the example comorbidities. Seven vital biomarkers from these diseases were selected to investigate the platform technology: lactoferrin (Lfn), immunoglobulin E (IgE), insulin, glucose, lactate, low density lipoprotein (LDL), and high density lipoprotein (HDL). Using electrochemical techniques such as amperometry and electrochemical impedance spectroscopy (EIS), various single- and dual-marker sensing prototypes were studied. First, by focusing on the imaginary impedance of EIS, an analytical algorithm for the determination of optimal frequency and signal deconvolution was first developed. This algorithm helped overcome the challenge of signal overlapping in EIS multi-marker sensors, while providing a means to study the optimal frequency of a biomarker. The algorithm was then applied to develop various single- and dual-marker prototypes by exploring different kinds of molecular recognition elements (MRE) while studying the optimal frequencies of various biomarkers with respect to their biological properties. Throughout the exploration, 5 single-marker biosensors (glucose, lactate, insulin, IgE, and Lfn) and one dual-marker (LDL and HDL) biosensor were successfully developed. With the aid of nanoparticles and the engineering design of experiments, the zeta potential, conductivity, and molecular weight of a biomarker were found to be three example factors that contribute to a biomarker’s optimal frequency. The study platforms used in the study did not achieve dual-enzymatic marker biosensors (glucose and lactate) due to signal contamination from localized accumulation of reduced electron mediators on self-assembled monolayer. However, amperometric biosensors for glucose and lactate with disposable test strips and integrated samplers were successfully developed as a back-up solution to the multi-marker sensing platform. This work has resulted in twelve publications, five patents, and one submitted manuscripts at the time of submission.
ContributorsLin, Chi En (Author) / La Belle, Jeffrey T (Thesis advisor) / Caplan, Michael (Committee member) / Cook, Curtiss B (Committee member) / Stabenfeldt, Sarah (Committee member) / Spano, Mark (Committee member) / Arizona State University (Publisher)
Created2018
156354-Thumbnail Image.png
Description
Traumatic brain injury (TBI) is a leading cause of disability worldwide with 1.7 million TBIs reported annually in the United States. Broadly, TBI can be classified into focal injury, associated with cerebral contusion, and diffuse injury, a widespread injury pathology. TBI results in a host of pathological alterations and may

Traumatic brain injury (TBI) is a leading cause of disability worldwide with 1.7 million TBIs reported annually in the United States. Broadly, TBI can be classified into focal injury, associated with cerebral contusion, and diffuse injury, a widespread injury pathology. TBI results in a host of pathological alterations and may lead to a transient blood-brain-barrier (BBB) breakdown. Although the BBB dysfunction after TBI may provide a window for therapeutic delivery, the current drug delivery approaches remains largely inefficient due to rapid clearance, inactivation and degradation. One potential strategy to address the current therapeutic limitations is to employ nanoparticle (NP)-based technology to archive greater efficacy and reduced clearance compared to standard drug administration. However, NP application for TBI is challenging not only due to the transient temporal resolution of the BBB breakdown, but also due to the heterogeneous (focal/diffuse) aspect of the disease itself. Furthermore, recent literature suggests sex of the animal influences neuroinflammation/outcome after TBI; yet, the influence of sex on BBB integrity following TBI and subsequent NP delivery has not been previously investigated. The overarching hypothesis for this thesis is that TBI-induced compromised BBB and leaky vasculature will enable delivery of systemically injected NPs to the injury penumbra. This study specifically explored the feasibility and the temporal accumulation of NPs in preclinical mouse models of focal and diffuse TBI. Key findings from these studies include the following. (1) After focal TBI, NPs ranging from 20-500nm exhibited peak accumulation within the injury penumbra acutely (1h) post-injury. (2) A smaller delayed peak of NP accumulation (40nm) was observed sub-acutely (3d) after focal brain injury. (3) Mild diffuse TBI simulated with a mild closed head injury model did not display any measurable NP accumulation after 1h post-injury. (4) In contrast, a moderate diffuse model (fluid percussion injury) demonstrated peak accumulation at 3h post-injury with up to 500 nm size NPs accumulating in cortical tissue. (5) Robust NP accumulation (40nm) was found in female mice compared to the males at 24h and 3d following focal brain injury. Taken together, these results demonstrate the potential for NP delivery at acute and sub-acute time points after TBI by exploiting the compromised BBB. Results also reveal a potential sex dependent component of BBB disruption leading to altered NP accumulation. The applications of this research are far-reaching ranging from theranostic delivery to personalized NP delivery for effective therapeutic outcome.
ContributorsBharadwaj, Vimala Nagabhushana (Author) / Stabenfeldt, Sarah E (Thesis advisor) / Kodibagkar, Vikram D (Thesis advisor) / Kleim, Jeffrey (Committee member) / Tian, Yanqing (Committee member) / Lifshitz, Jonathan (Committee member) / Anderson, Trent R (Committee member) / Arizona State University (Publisher)
Created2018
136352-Thumbnail Image.png
Description
Electrical stimulation has previously been effective in neural cells activation within retinas affected by degenerative retinal disease. However current technology has at most allowed blind individuals to perceive light without significant resolution, as implants are limited by the spatial constraints of the eye. Photoreactive nanoparticles may provide a solution to

Electrical stimulation has previously been effective in neural cells activation within retinas affected by degenerative retinal disease. However current technology has at most allowed blind individuals to perceive light without significant resolution, as implants are limited by the spatial constraints of the eye. Photoreactive nanoparticles may provide a solution to this issue, as their small size would allow for the incorporation of higher numbers of stimulatory elements, thus increasing visual resolution. Semiconductive nanocrystal quantum dots (QDs) and gold nanoparticles (AuNPs) both exhibit photoreactive properties which may result in sufficient electrical stimulation to activate neural cells in the retina. This study investigated the electrochemistry and photoreactivity of QDs and AuNPs encapsulated within the hydrophobic region of small unilamellar lipid vesicles (SUVs) to evaluate their potential for application in retinal stimulation. Absorbance of the constructs was evaluated on the day of fabrication and 24 hours later to determine the ability of the particles to react to light while encapsulated, as well as to evaluate stability of the construct over time. Electrical impedance spectroscopy (EIS) was conducted at both time points to determine the electrochemical character of the bilayer and further evaluate construct stability. Although quantum dots may increase the stability of the bilayer over time and improve its capacitative properties, lipid encapsulation appears to obscure the photoreactive properties of the quantum dots. In the case of gold nanoparticles, the construct is initially stabilized but deteriorates more quickly than those SUVs containing quantum dots, as evidenced by an increase in substrate diffusion. Additionally, although these constructs are more photoreactive than those containing QDs, the increase in absorbance is observed primarily in a range below that of the visible spectrum, a feature which is of limited use for the proposed application. Further studies should investigate alternative methods of nanoparticle capping to improve stability and absorbance in this system.
ContributorsReidell, Olivia Rose (Author) / La Belle, Jeffrey T (Thesis director) / Coursen, Jerry (Committee member) / Barrett, The Honors College (Contributor) / School of Mathematical and Statistical Sciences (Contributor) / School of Life Sciences (Contributor)
Created2015-05
154106-Thumbnail Image.png
Description
Traumatic brain injury (TBI) is a significant public health concern in the U.S., where approximately 1.7 million Americans sustain a TBI annually, an estimated 52,000 of which lead to death. Almost half (43%) of all TBI patients report experiencing long-term cognitive and/or motor dysfunction. These long-term deficits are largely due

Traumatic brain injury (TBI) is a significant public health concern in the U.S., where approximately 1.7 million Americans sustain a TBI annually, an estimated 52,000 of which lead to death. Almost half (43%) of all TBI patients report experiencing long-term cognitive and/or motor dysfunction. These long-term deficits are largely due to the expansive biochemical injury that underlies the mechanical injury traditionally associated with TBI. Despite this, there are currently no clinically available therapies that directly address these underlying pathologies. Preclinical studies have looked at stem cell transplantation as a means to mitigate the effects of the biochemical injury with moderate success; however, transplants suffer very low retention and engraftment rates (2-4%). Therefore, transplants need better tools to dynamically respond to the injury microenvironment.

One approach to develop new tools for stem cell transplants may be to look towards the endogenous repair response for inspiration. Specifically, activated cell types surrounding the injury secrete the chemokine stromal cell-derived factor-1α (SDF-1α), which has been shown to play a critical role in recruiting endogenous neural progenitor/stem cells (NPSCs) to the site of injury. Therefore, it was hypothesized that improving NPSC response to SDF-1α may be a viable mechanism for improving NPSC transplant retention and migration into the surrounding host tissue. To this end, work presented here has 1. identified critical extracellular signals that mediate the NPSC response to SDF-1α, 2. incorporated these findings into the development of a transplantation platform that increases NPSC responsiveness to SDF-1α and 3. observed increased NPSC responsiveness to local exogenous SDF-1α signaling following transplantation within our novel system. Future work will include studies investigating NSPC response to endogenous, injury-induced SDF-1α and the application of this work to understanding differences between stem cell sources and their implications in cell therapies.
ContributorsAddington, Caroline (Author) / Stabenfeldt, Sarah E (Thesis advisor) / Kleim, Jeffrey A (Committee member) / Caplan, Michael R (Committee member) / Lifshitz, Jonathan (Committee member) / Massia, Stephen P (Committee member) / Arizona State University (Publisher)
Created2015
154988-Thumbnail Image.png
Description
Stromal cell-derived factor-1α (SDF-1α) and its key receptor, CXCR4 are ubiquitously expressed in systems across the body (e.g. liver, skin, lung, etc.). This signaling axis regulates a myriad of physiological processes that range from maintaining of organ homeostasis in adults to, chemotaxis of stem/progenitor and immune cell types after injury.

Stromal cell-derived factor-1α (SDF-1α) and its key receptor, CXCR4 are ubiquitously expressed in systems across the body (e.g. liver, skin, lung, etc.). This signaling axis regulates a myriad of physiological processes that range from maintaining of organ homeostasis in adults to, chemotaxis of stem/progenitor and immune cell types after injury. Given its potential role as a therapeutic target for diverse applications, surprisingly little is known about how SDF-1α mediated signaling propagates through native tissues. This limitation ultimately constrains rational design of interventional biomaterials that aim to target the SDF-1α/CXCR4 signaling axis. One application of particular interest is traumatic brain injury (TBI) for which, there are currently no means of targeting the underlying biochemical pathology to improve prognosis.

Growing evidence suggests a relationship between SDF-1α/CXCR4 signaling and endogenous neural progenitor/stem cells (NPSC)-mediated regeneration after neural injury. Long-term modulation of the SDF-1α/CXCR4 signaling axis is thus hypothesized as a possible avenue for harnessing and amplifying endogenous regenerative mechanisms after TBI. In order to understand how the SDF-1α/CXCR4 signaling can be modulated in vivo, we first developed and characterized a sustained protein delivery platform in vitro. We were the first, to our knowledge, to demonstrate that protein release profiles from poly(D,L,-lactic-co-glycolic) acid (PLGA) particles can be tuned independent of particle fabrication parameters via centrifugal fractioning. This process of physically separating the particles altered the average diameter of a particle population, which is in turn was correlated to critical release characteristics. Secondly, we demonstrated sustained release of SDF-1α from PLGA/fibrin composites (particles embedded in fibrin) with tunable burst release as a function of fibrin concentration. Finally, we contrasted the spatiotemporal localization of endogenous SDF-1α and CXCR4 expression in response to either bolus or sustained release of exogenous SDF-1α. Sustained release of exogenous SDF-1α induced spatially diffuse endogenous SDF-1/CXCR4 expression relative to bolus SDF-1 administration; however, the observed effects were transient in both cases, persisting only to a maximum of 3 days post injection. These studies will inform future systematic evaluations of strategies that exploit SDF-1α/CXCR4 signaling for diverse applications.
ContributorsDutta, Dipankar (Author) / Stabenfeldt, Sarah E (Thesis advisor) / Kleim, Jeffrey (Committee member) / Nikkhah, Mehdi (Committee member) / Sirianni, Rachael (Committee member) / Vernon, Brent (Committee member) / Arizona State University (Publisher)
Created2016
155756-Thumbnail Image.png
Description
According to sources of the Centers for Disease Control and Prevention, approximately 1.7 million traumatic brain injury (TBI) cases occur annually in the United States. TBI results in 50 thousand deaths, nearly 300 thousand hospitalizations and 2.2 million emergency room visits causing a $76 billion economic burden in direct and

According to sources of the Centers for Disease Control and Prevention, approximately 1.7 million traumatic brain injury (TBI) cases occur annually in the United States. TBI results in 50 thousand deaths, nearly 300 thousand hospitalizations and 2.2 million emergency room visits causing a $76 billion economic burden in direct and indirect costs. Furthermore, it is estimated that over 5 million TBI survivors in the US are struggling with long-term disabilities. And yet, a point-of-care TBI diagnostic has not replaced the non-quantitative cognitive and physiological methods used today. Presently, pupil dilation and the Glasgow Coma Scale (GCS) are clinically used to diagnose TBI. However, GSC presents difficulties in detecting subtle patient changes, oftentimes leaving mild TBI undiagnosed. Given the long-term deficits associated with TBIs, a quantitative method that enables capturing of subtle and changing TBI pathologies is of great interest to the field.

The goal of this research is to work towards a test strip and meter point-of-care technology (similar to the glucose meter) that will quantify several TBI biomarkers in a drop of whole blood simultaneously. It is generally understood that measuring only one blood biomarker may not accurately diagnose TBI, thus this work lays the foundation to develop a multi-analyte approach to detect four promising TBI biomarkers: glial fibrillary acidic protein (GFAP), neuron specific enolase (NSE), S-100β protein, and tumor necrosis factor-α (TNF-α). To achieve this, each biomarker was individually assessed and modeled using sensitive and label-free electrochemical impedance techniques first in purified, then in blood solutions using standard electrochemical electrodes. Next, the biomarkers were individually characterized using novel mesoporous carbon electrode materials to facilitate detection in blood solutions and compared to the commercial standard Nafion coating. Finally, the feasibility of measuring these biomarkers in the same sample simultaneously was explored in purified and blood solutions. This work shows that a handheld TBI blood diagnostic is feasible if the electronics can be miniaturized and large quantity production of these sensors can be achieved.
ContributorsCardinell, Brittney Ann (Author) / La Belle, Jeffrey T (Thesis advisor) / Spano, Mark L (Committee member) / Stabenfeldt, Sarah E (Committee member) / Kleim, Jeffrey A (Committee member) / Cook, Curtiss B (Committee member) / Arizona State University (Publisher)
Created2017
155548-Thumbnail Image.png
Description
Prosthetic joint infection (PJI) is a devastating complication associated with total joint arthroplasty that results in high cost and patient morbidity. There are approximately 50,000 PJIs per year in the US, imposing a burden of about $5 billion on the healthcare system. PJI is especially difficult to treat because of

Prosthetic joint infection (PJI) is a devastating complication associated with total joint arthroplasty that results in high cost and patient morbidity. There are approximately 50,000 PJIs per year in the US, imposing a burden of about $5 billion on the healthcare system. PJI is especially difficult to treat because of the presence of bacteria in biofilm, often highly tolerant to antimicrobials. Treatment of PJI requires surgical debridement of infected tissues, and local, sustained delivery of antimicrobials at high concentrations to eradicate residual biofilm bacteria. However, the antimicrobial concentrations required to eradicate biofilm bacteria grown in vivo or on tissue surfaces have not been measured. In this study, an experimental rabbit femur infection model was established by introducing a variety of pathogens representative of those found in PJIs [Staphylococcus Aureus (ATCC 49230, ATCC BAA-1556, ATCC BAA-1680), Staphylococcus Epidermidis (ATCC 35984, ATCC 12228), Enterococcus Faecalis (ATCC 29212), Pseudomonas Aeruginosa (ATCC 27853), Escherichia Coli (ATCC 25922)]. Biofilms of the same pathogens were grown in vitro on biologic surfaces (bone and muscle). The ex vivo and in vitro tissue minimum biofilm eradication concentration (MBEC; the level required to eradicate biofilm bacteria) and minimum inhibitory concentration (MIC; the level required to inhibit planktonic, non-biofilm bacteria) were measured using microbiological susceptibility assays against tobramycin (TOB) and vancomycin (VANC) alone or in 1:1 weight combination of both (TOB+VANC) over three exposure durations (6 hour, 24 hour, 72 hour). MBECs for all treatment combinations (pathogen, antimicrobial used, exposure time, and tissue) were compared against the corresponding MIC values to compare the relative susceptibility increase due to biofilm formation. Our data showed median in vitro MBEC to be 100-1000 times greater than the median MIC demonstrating the administration of local antimicrobial doses at MIC level would not kill the persisting bacteria in biofilm. Also, administering dual agent (TOB+VANC) showed median MBEC values to be comparable or lower than the single agents (TOB or VANC)
ContributorsBadha, Vajra Sabhapathy (Author) / Vernon, Brent L (Thesis advisor) / Caplan, Michael R (Committee member) / Stabenfeldt, Sarah E (Committee member) / Overstreet, Derek J (Committee member) / Arizona State University (Publisher)
Created2017