Matching Items (14)
157473-Thumbnail Image.png
Description
The goal of this research was to study the effect of dilution on ammonium and potassium removal from real hydrolyzed urine. The performance of two natural zeolites, clinoptilolite and chabazite, was studied and compared with the help of batch equilibrium experiments at four dilution levels: 100%, 10%, 1% and 0.1%

The goal of this research was to study the effect of dilution on ammonium and potassium removal from real hydrolyzed urine. The performance of two natural zeolites, clinoptilolite and chabazite, was studied and compared with the help of batch equilibrium experiments at four dilution levels: 100%, 10%, 1% and 0.1% (urine volume/total solution volume). Further, the sorption behavior of other exchangeable ions (sodium, calcium and magnesium) in clinoptilolite and chabazite was studied to improve the understanding of ion exchange stoichiometry. Ammonium and potassium removal were highest at undiluted level in samples treated with clinoptilolite. This is a key finding as it illustrates the benefit of urine source separation. Chabazite treated samples showed highest ammonium and potassium removal at undiluted level at lower doses. At higher doses, potassium removal was similar in undiluted and 10% urine solutions whereas ammonium removal was the highest in 10% urine solutions. In general, chabazite showed higher ammonium and potassium removal than clinoptilolite. The result showed that ion exchange was stoichiometric in solutions with higher urine volumes.
ContributorsRegmi, Urusha (Author) / Boyer, Treavor H (Thesis advisor) / Delgado, Anca G (Committee member) / Hamilton, Kerry (Committee member) / Arizona State University (Publisher)
Created2019
156925-Thumbnail Image.png
Description
The occurrence of micro-and nanoplastic (MNP) debris in the environment is a research area of considerable public health concern. Various combinations of methods for extraction, isolation, and quantification of MNP have been applied but literature studies evaluating the appropriateness and efficacy of these protocols are lacking. A meta-analysis of the

The occurrence of micro-and nanoplastic (MNP) debris in the environment is a research area of considerable public health concern. Various combinations of methods for extraction, isolation, and quantification of MNP have been applied but literature studies evaluating the appropriateness and efficacy of these protocols are lacking. A meta-analysis of the literature (n=134; years 2010-2017) was conducted to inventory and assess the appropriateness of methodologies employed. Some 30.6% of studies employed visual identification only, which carried a calculated misidentification error of 25.8-74.2%. An additional 6.7% of studies reported counts for particles smaller than the cutoff value of the selected collection pore size, and 9.7% of studies utilized extraction solution densities which exclude some of the polymers commonly occurring in the environments investigated. A composite value of data vulnerability of 43.3% was determined for the sample, indicating considerable weaknesses in the robustness of information available on MNP occurrence and type. Additionally, the oxidizing solutions documented in the literature frequently were deemed unsuccessful in removing interfering organic matter. Whereas nanoplastics measuring <1 µm in diameter are likely principal drivers of health risk, polymer fragments reported on in the literature are much larger, measuring 10+ µm in diameter due to lack of standardized methods. Thus, current inventories of MNP in the environmental MNP feature data quality concerns that should be addressed moving forward by using more robust and standardized techniques for sampling, processing and polymer identification to improve data quality and avoid the risk of misclassification.
ContributorsCook, Cayla R (Author) / Halden, Rolf U. (Thesis advisor) / Hamilton, Kerry (Committee member) / Mascaro, Giuseppe (Committee member) / Arizona State University (Publisher)
Created2018
168288-Thumbnail Image.png
Description
Intensified food production on large farms across the world has led to discussions on how to facilitate sustainable policies and practices to reduce nutrient pollution. In Chapter 1, I evaluated the co-variability of agricultural intensification, environmental degradation, and socio-economic indicators throughout the US to explore the potential evidence for the

Intensified food production on large farms across the world has led to discussions on how to facilitate sustainable policies and practices to reduce nutrient pollution. In Chapter 1, I evaluated the co-variability of agricultural intensification, environmental degradation, and socio-economic indicators throughout the US to explore the potential evidence for the existence of sustainable intensification of agriculture in the US. I identified distinct agro-social-eco regions in the US that provide background for future regional studies of (sustainable intensification) SI in the US and beyond. I observed regions of moderate agricultural intensity and lower environmental degradation within the Great Plains, and regions of high agricultural intensity and higher environmental degradation throughout portions of the Midwest. Insights gained from this study can provide roadmaps for improved sustainable agricultural intensification within the US. In Chapter 2, the study summarized state regulations controlling a key nutrient input - the land application of biosolids from human wastewater treatment and manures from regulated animal feeding operations. Results indicate high variability of both manure and biosolids regulations among the states and stark differences in the regulation of land application of biosolids versus manures. This work can be used to identify opportunities for the strengthening of regulatory frameworks for managing these resources with minimal risk to the environment. In Chapter 3, I combined aspects of the previous chapters to understand the potential impact of specific CAFO land application regulations on nutrient pollution and assess if stricter regulations related to better environmental outcomes. I compared TN AND TP accumulated yields in surface waters across US States with state specific CAFO land application regulations across US Policy scenario tests revealed that more restrictions were associated with higher nutrient levels, indicating reactive policy making and delayed nonpoint source pollution responses. Overall, I found that fostering adaptive capacity and management within delineated agro-social-eco regions will likely facilitate sustainable food systems in the US.
ContributorsRauh, Eleanor (Author) / Muenich, Rebecca (Thesis advisor) / Compton, Jana (Committee member) / Parker, Nathan (Committee member) / Hamilton, Kerry (Committee member) / Arizona State University (Publisher)
Created2021
Description

This research aims to develop an understanding of how interventions designed to improve water quality in buildings can be used to mitigate Legionella pneumophila concentrations. Intervention methods can be described as any approach that can be used to improve microbial water quality. In order to provide a foundation of background

This research aims to develop an understanding of how interventions designed to improve water quality in buildings can be used to mitigate Legionella pneumophila concentrations. Intervention methods can be described as any approach that can be used to improve microbial water quality. In order to provide a foundation of background knowledge, a literature review was conducted to identify similar studies and collect relevant and timely research similar to the subject. The information gathered from the literature review was used to structure the sampling process and parameters. Using the research collected from the literature review, a review table was created to summarize the differences in the studies conducted and to determine research gaps. To categorize the studies, intervention methods, contaminants addressed, and water quality meta-data were differentiated for each of the articles. For the purpose of the sampling process, the three interventions analyzed consist of flushing, water heater set point change, and both flushing and water heater set point change. The locations of the sampling consisted of the city drinking water inlet, the basement janitor's closet, basement shower, 2nd floor, 3rd floor, and 7th floor break rooms and restrooms of the Interdisciplinary Science and Technology Building IV at ASU. For the flushing intervention, the sampling results demonstrated an increase in free and total chlorine concentration post flushing which aligns with the research found in the literature review. In addition, it was observed that iron concentrations drastically increased for both the cold and hot water by flushing. There was a significant decrease detected for ATP concentrations post flush in the hot line. However through the sampling session, the flushing intervention did not yield statistically significant results for Legionella concentrations.

ContributorsCahill, Molly (Author) / Call, Kathryn (Co-author) / Johnson, Elizabeth (Co-author) / Kotta, Vishnu (Co-author) / Hamilton, Kerry (Thesis director) / Boyer, Treavor (Committee member) / Barrett, The Honors College (Contributor) / School of Sustainable Engineering & Built Envirnmt (Contributor)
Created2023-05
Description

This research aims to develop an understanding of how interventions designed to improve water quality in buildings can be used to mitigate Legionella pneumophila concentrations. Intervention methods can be described as any approach that can be used to improve microbial water quality. In order to provide a foundation of background

This research aims to develop an understanding of how interventions designed to improve water quality in buildings can be used to mitigate Legionella pneumophila concentrations. Intervention methods can be described as any approach that can be used to improve microbial water quality. In order to provide a foundation of background knowledge, a literature review was conducted to identify similar studies and collect relevant and timely research similar to the subject. The information gathered from the literature review was used to structure the sampling process and parameters. Using the research collected from the literature review, a review table was created to summarize the differences in the studies conducted and to determine research gaps. To categorize the studies, intervention methods, contaminants addressed, and water quality meta-data were differentiated for each of the articles. For the purpose of the sampling process, the three interventions analyzed consist of flushing, water heater set point change, and both flushing and water heater set point change. The locations of the sampling consisted of the city drinking water inlet, the basement janitor's closet, basement shower, 2nd floor, 3rd floor, and 7th floor break rooms and restrooms of the Interdisciplinary Science and Technology Building IV at ASU. For the flushing intervention, the sampling results demonstrated an increase in free and total chlorine concentration post flushing which aligns with the research found in the literature review. In addition, it was observed that iron concentrations drastically increased for both the cold and hot water by flushing. There was a significant decrease detected for ATP concentrations post flush in the hot line. However through the sampling session, the flushing intervention did not yield statistically significant results for Legionella concentrations.

ContributorsJohnson, Elizabeth (Author) / Call, Kathryn (Co-author) / Cahill, Molly (Co-author) / Kotta, Vishnu (Co-author) / Hamilton, Kerry (Thesis director) / Boyer, Treavor (Committee member) / Barrett, The Honors College (Contributor) / School of Sustainable Engineering & Built Envirnmt (Contributor) / Dean, W.P. Carey School of Business (Contributor)
Created2023-05
Description

This research aims to develop an understanding of how interventions designed to improve water quality in buildings can be used to mitigate Legionella pneumophila concentrations. Intervention methods can be described as any approach that can be used to improve microbial water quality. In order to provide a foundation of background

This research aims to develop an understanding of how interventions designed to improve water quality in buildings can be used to mitigate Legionella pneumophila concentrations. Intervention methods can be described as any approach that can be used to improve microbial water quality. In order to provide a foundation of background knowledge, a literature review was conducted to identify similar studies and collect relevant and timely research similar to the subject. The information gathered from the literature review was used to structure the sampling process and parameters. Using the research collected from the literature review, a review table was created to summarize the differences in the studies conducted and to determine research gaps. To categorize the studies, intervention methods, contaminants addressed, and water quality meta-data were differentiated for each of the articles. For the purpose of the sampling process, the three interventions analyzed consist of flushing, water heater set point change, and both flushing and water heater set point change. The locations of the sampling consisted of the city drinking water inlet, the basement janitor's closet, basement shower, 2nd floor, 3rd floor, and 7th floor break rooms and restrooms of the Interdisciplinary Science and Technology Building IV at ASU. For the flushing intervention, the sampling results demonstrated an increase in free and total chlorine concentration post flushing which aligns with the research found in the literature review. In addition, it was observed that iron concentrations drastically increased for both the cold and hot water by flushing. There was a significant decrease detected for ATP concentrations post flush in the hot line. However through the sampling session, the flushing intervention did not yield statistically significant results for Legionella concentrations.

ContributorsCall, Kathryn (Author) / Cahill, Molly (Co-author) / Johnson, Elizabeth (Co-author) / Kotta, Vishnu (Co-author) / Hamilton, Kerry (Thesis director) / Boyer, Treavor (Committee member) / Barrett, The Honors College (Contributor) / School of Sustainable Engineering & Built Envirnmt (Contributor)
Created2023-05
187564-Thumbnail Image.png
Description
Pathogens can proliferate in the built environment and can cause disease outbreaks if water and wastewater are not properly managed. Understanding pathogens that grow in engineered systems is crucial to protecting public health and preventing disease. Using dynamic computational models can reveal mechanistic insights into these systems to aid in

Pathogens can proliferate in the built environment and can cause disease outbreaks if water and wastewater are not properly managed. Understanding pathogens that grow in engineered systems is crucial to protecting public health and preventing disease. Using dynamic computational models can reveal mechanistic insights into these systems to aid in understanding risk drivers and determining risk management strategies. The first research chapter of this thesis investigates tradeoffs for reducing the cost associated with Legionnaire’s Disease, hot water scalding, and energy use using a computational framework for evaluating an optimal water heater temperature set point. The model demonstrated that the optimal temperature set point was highly dependent on assumptions made regarding the dose response parameter for a common configuration of an electric water heater in a hospital setting. The optimal temperature was 55°C or 48°C for subclinical vs. clinical severity dose response, respectively, compared with current recommendations of 60°C to kill bacteria and 49°C to prevent scalding and conserve energy. The second research chapter models the population dynamics of antibiotic-susceptible Escherichia coli (E. coli) and antibiotic-resistant E. coli with a population ecology-exposure assessment model in surface water to quantify the risk of urinary tract infection from recreational swimming activities. Horizontal gene transfer (HGT) was modeled in the environment and the human gastrointestinal tract for several scenarios. HGT was generally not a dominant driver of exposure estimates compared to other factors such as growth and dilution, however, the rank order of factors was scenario-dependent. The final research chapter models pathogen transport from wastewater treatment plant (WWTP) exposures and assesses the risk to workers based on several exposure scenarios. Case studies were performed to investigate infection risk drivers across different scenarios, including adjustments for the timing of exposure and personal protective equipment. A web application was developed for use by WWTP risk managers to be used with site-specific data. The proposed modeling frameworks identified risk drivers across several microbial risk scenarios and provide flexible tools for risk managers to use when making water treatment and use decisions for water management plans used for premise plumbing as well as for wastewater treatment practices.
ContributorsHeida, Ashley (Author) / Hamilton, Kerry (Thesis advisor) / Garcia, Margared (Committee member) / Muenich, Rebecca (Committee member) / Wilson, Amanda (Committee member) / Arizona State University (Publisher)
Created2023
171635-Thumbnail Image.png
Description
This study investigated the difference in biofilm growth on pristine and aged polypropylene microplastics exposed to Tempe Town Lake water for 8 weeks. The research question here is, does the aging of microplastic (MPs) change the biofilm formation rate and composition of the biofilm in comparison with the pristine MPs.

This study investigated the difference in biofilm growth on pristine and aged polypropylene microplastics exposed to Tempe Town Lake water for 8 weeks. The research question here is, does the aging of microplastic (MPs) change the biofilm formation rate and composition of the biofilm in comparison with the pristine MPs. To answer this question, the biofilm formation was quantified using different methods over time for both pristine polypropylene and aged polypropylene using agar plate counts and crystal violet staining. Colony counts based on agar plating showed an increase in microbial growth over the 8 weeks of treatment, with the aged MPs accumulating higher microbial counts than the pristine MPs. The diversity of the biofilm decreased over time for both MPs and the aged MPs had overall less diversity in biofilm, based on phenotype enumeration, in comparison with the pristine MPs. Higher biofilm growth on aged MPs was confirmed using crystal violet staining, which stains the negatively charged biological compounds such as proteins and the extracellular polymeric substance matrix of the biofilm. Using this complementary approach to colony counting, the same trend of higher biofilm growth on aged MPs was found. Further studies will focus on confirming the phenotype findings using microbiome analysis following DNA extraction. This project created a methodology to quantify biofilm formation on MPs, which was used to show that MPs may accumulate more biofilms in the environment as they age under sunlight.
ContributorsMushro, Noelle (Author) / Perreault, Francois (Thesis advisor) / Hamilton, Kerry (Committee member) / Krajmalnik-Brown, Rosa (Committee member) / Arizona State University (Publisher)
Created2022
Description
-Please adjust the format of the abstract. m-3 should be typed as "m to the minus 3" with the "minus 3" in superscript
-see the additional "abstract.pdf" document for formatting
In arid environments like Phoenix, many professional and residential outdoor spaces are cooled by the use of misting systems. These systems spray

-Please adjust the format of the abstract. m-3 should be typed as "m to the minus 3" with the "minus 3" in superscript
-see the additional "abstract.pdf" document for formatting
In arid environments like Phoenix, many professional and residential outdoor spaces are cooled by the use of misting systems. These systems spray a fine mist of water droplets that cool down the surrounding air through the endothermic evaporation process. When the water droplets evaporate, they leave behind dissolved material that is present in the water, generating ambient particulate matter (PM). Thus, misting systems are a point source of PM. Currently there is no information on their impact on air quality in close proximity to these systems, or on the chemical composition of the particulate matter generated by the evaporating mist.
In this project, PM concentrations are found to increase on average by a factor of 8 from ambient levels in the vicinity of a residential misting system in controlled experiments. PM concentrations in public places that use misting systems are also investigated. The PM10 concentrations in public places ranged from 0.102 ± 0.010 mg m-3 to 1.47 ± 0.15 mg m-3, and PM2.5 ranged from 0.095 ± 0.010 mg m-3 to 0.99 ± 0.10 mg m-3. Air quality index (AQI) values based on these concentrations indicate that these levels of PM range from unhealthy to hazardous in most cases. PM concentrations tend to decrease after remaining relatively constant with increasing distance from misting systems. Chemical data reveal that chloride and magnesium ions may be used as tracers of aerosolized water from misting systems. The average chloride concentration was 71 µg m-3 in misting samples and below the detection limit for Cl- (< 8.2 µg m-3) in ambient samples. The average magnesium concentration was 11.7 µg m-3 in misting samples and 0.23 µg m-3 in ambient samples.
ContributorsKnight, William Louis (Co-author) / Knight, William (Co-author) / Herckes, Pierre (Thesis director) / Fraser, Matthew (Committee member) / Hamilton, Kerry (Committee member) / School of Sustainability (Contributor) / School of Molecular Sciences (Contributor) / Barrett, The Honors College (Contributor)
Created2020-05
165168-Thumbnail Image.png
Description
Water is a scarce resource that is recycled through wastewater treatment plants (WWTPs) to help fulfill the demand for water. Agriculture is a large consumer of water, indicating that WWTP-treated water is proportionally applied to crops at a high rate. Recycled water is highly regulated but is capable of containing

Water is a scarce resource that is recycled through wastewater treatment plants (WWTPs) to help fulfill the demand for water. Agriculture is a large consumer of water, indicating that WWTP-treated water is proportionally applied to crops at a high rate. Recycled water is highly regulated but is capable of containing high-risk pathogens and contaminants despite the efforts of physical and microbial treatments throughout the WWTP process. WWTPs are also producers of biosolids, treated sewage sludge regulated by the EPA that can be applied in agricultural settings to act as a fertilizer. Biosolids are a useful fertilizer as they are rich in nitrogen and contain many beneficial nutrients for soil and crops. Due to biosolids being a by-product of recycled water, they are susceptible to containing the same pathogens and contaminants that can be transferred in the WWTP systems. Antibiotic resistance (AR) is an ever-growing threat on a global scale and is one of the areas of concern for consideration of pathogen spread from WWTPs. Antibiotic resistance bacteria, created through mutation of bacterial plasmids producing antibiotic resistance genes (ARGs), have been quantified and studied to help mitigate the risk posed by continued AR spread in the environment. This study aims to produce a comprehensive collection of quantified ARG concentration data in biosolids, as well as producing a QMRA model integrating Monte Carlo distributions to provide groundwork for understanding of the direct dosage and consumption of ARGs to the standard U.S. citizen. The study determined that sul1, sul2, tetM, and tetO are ARGs of high concern in biosolid samples based on current concentration data of biosolid samples. The resulting dose models and gene concentration distributions provide data to support the need to mitigate AR risk presented by agricultural biosolid application.
ContributorsMorgan, Grace (Author) / Hamilton, Kerry (Thesis director) / Muenich, Rebecca (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2022-05