Matching Items (8)
157386-Thumbnail Image.png
Description
Minimally invasive endovascular embolization procedures decrease surgery time, speed up recovery, and provide the possibility for more comprehensive treatment of aneurysms, arteriovenous malformations (AVMs), and hypervascular tumors. Liquid embolic agents (LEAs) are preferred over mechanical embolic agents, such as coils, because they achieve homogeneous filling of aneurysms and more complex

Minimally invasive endovascular embolization procedures decrease surgery time, speed up recovery, and provide the possibility for more comprehensive treatment of aneurysms, arteriovenous malformations (AVMs), and hypervascular tumors. Liquid embolic agents (LEAs) are preferred over mechanical embolic agents, such as coils, because they achieve homogeneous filling of aneurysms and more complex angioarchitectures. The gold standard of commercially available LEAs is dissolved in dimethyl sulfoxide (DMSO), which has been associated with vasospasm and angiotoxicity. The aim of this study was to investigate amino acid substitution in an enzyme-degradable side group of an N-isopropylacrylamide (NIPAAm) copolymer for the development of a LEA that would be delivered in water and degrade at the rate that tissue is regenerated. NIPAAm copolymers have a lower critical solution temperature (LCST) due to their amphiphilic nature. This property enables them to be delivered as liquids through a microcatheter below their LCST and to solidify in situ above the LCST, which would result in the successful selective occlusion of blood vessels. Therefore, in this work, a series of poly(NIPAAm-co-peptide) copolymers with hydrophobic side groups containing the Ala-Pro-Gly-Leu collagenase substrate peptide sequence were synthesized as in situ forming, injectable copolymers.. The Gly-Leu peptide bond in these polypeptides is cleaved by collagenase, converting the side group into the more hydrophilic Gly-Ala-Pro-Gly-COOH (GAPG-COOH), thus increasing the LCST of the hydrogel after enzyme degradation. Enzyme degradation property and moderate mechanical stability convinces the use of these copolymers as liquid embolic agents.
ContributorsRosas Gomez, Karime Jocelyn (Author) / Vernon, Brent (Thesis advisor) / Weaver, Jessica (Committee member) / Pal, Amrita (Committee member) / Arizona State University (Publisher)
Created2019
136509-Thumbnail Image.png
Description
The primary objective of this research project is to develop dual layered polymeric microparticles with a tunable delayed release profile. Poly(L-lactic acid) (PLA) and poly(lactic-co-glycolic acid) (PLGA) phase separate in a double emulsion process due to differences in hydrophobicity, which allows for the synthesis of double-walled microparticles with a PLA

The primary objective of this research project is to develop dual layered polymeric microparticles with a tunable delayed release profile. Poly(L-lactic acid) (PLA) and poly(lactic-co-glycolic acid) (PLGA) phase separate in a double emulsion process due to differences in hydrophobicity, which allows for the synthesis of double-walled microparticles with a PLA shell surrounding the PLGA core. The microparticles were loaded with bovine serum albumin (BSA) and different volumes of ethanol were added to the PLA shell phase to alter the porosity and release characteristics of the BSA. Different amounts of ethanol varied the total loading percentage of the BSA, the release profile, surface morphology, size distribution, and the localization of the protein within the particles. Scanning electron microscopy images detailed the surface morphology of the different particles. Loading the particles with fluorescently tagged insulin and imaging the particles through confocal microscopy supported the localization of the protein inside the particle. The study suggest that ethanol alters the release characteristics of the loaded BSA encapsulated in the microparticles supporting the use of a polar, protic solvent as a tool for tuning the delayed release profile of biological proteins.
ContributorsFauer, Chase Alexander (Author) / Stabenfeldt, Sarah (Thesis director) / Ankeny, Casey (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2015-05
148276-Thumbnail Image.png
Description

Polymer drug delivery system offers a key to a glaring issue in modern administration routes of drugs and biologics. Poly(lactic-co-glycolic acid) (PLGA) can be used to encapsulate drugs and biologics and deliver them into the patient, which allows high local concentration (compared to current treatment methods), protection of the cargo

Polymer drug delivery system offers a key to a glaring issue in modern administration routes of drugs and biologics. Poly(lactic-co-glycolic acid) (PLGA) can be used to encapsulate drugs and biologics and deliver them into the patient, which allows high local concentration (compared to current treatment methods), protection of the cargo from the bodily environment, and reduction in systemic side effects. This experiment used a single emulsion technique to encapsulate L-tyrosine in PLGA microparticles and UV spectrophotometry to analyze the drug release over a period of one week. The release assay found that for the tested samples, the released amount is distinct initially, but is about the same after 4 days, and they generally follow the same normalized percent released pattern. The experiment could continue with testing more samples, test the same samples for a longer duration, and look into higher w/w concentrations such as 20% or 50%.

ContributorsSeo, Jinpyo (Author) / Vernon, Brent (Thesis director) / Pal, Amrita (Committee member) / Dean, W.P. Carey School of Business (Contributor) / Harrington Bioengineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
Description

The goal of this research project is to create a Mathcad template file capable of statistically modelling the effects of mean and standard deviation on a microparticle batch characterized by the log normal distribution model. Such a file can be applied during manufacturing to explore tolerances and increase cost and

The goal of this research project is to create a Mathcad template file capable of statistically modelling the effects of mean and standard deviation on a microparticle batch characterized by the log normal distribution model. Such a file can be applied during manufacturing to explore tolerances and increase cost and time effectiveness. Theoretical data for the time to 60% drug release and the slope and intercept of the log-log plot were collected and subjected to statistical analysis in JMP. Since the scope of this project focuses on microparticle surface degradation drug release with no drug diffusion, the characteristic variables relating to the slope (n = diffusional release exponent) and the intercept (k = kinetic constant) do not directly apply to the distribution model within the scope of the research. However, these variables are useful for analysis when the Mathcad template is applied to other types of drug release models.

ContributorsHan, Priscilla (Author) / Vernon, Brent (Thesis director) / Nickle, Jacob (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2021-05
131635-Thumbnail Image.png
Description
There is an increasing interest in developing thermo-responsive polymers for treating aneurysms. In this thesis project, the potential for poly(NIPAAm-co-JAAm-co-HEMA-Acrylate) (PNJHAc) as a treatment method for brain aneurysms was investigated. Five different batches of polymer were synthesized, purified, lyophilized, and characterized using nuclear magnetic resonance and cloud point techniques over

There is an increasing interest in developing thermo-responsive polymers for treating aneurysms. In this thesis project, the potential for poly(NIPAAm-co-JAAm-co-HEMA-Acrylate) (PNJHAc) as a treatment method for brain aneurysms was investigated. Five different batches of polymer were synthesized, purified, lyophilized, and characterized using nuclear magnetic resonance and cloud point techniques over the course of several months. Two were tested in aneurysm models. Of these five batches, there were two that showed promise as liquid embolic agents for endovascular embolization.
ContributorsLoui, Michelle (Author) / Vernon, Brent (Thesis director) / Pal, Amrita (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2020-05
131784-Thumbnail Image.png
Description
In an embolization therapy, a material is injected into a vessel to block blood flow. While this therapy is useful in starving cancerous cells it can be dangerous, with some blockades in the brain dislodging and causing strokes or blindness. Currently, embolic materials on the market such as metal coils,

In an embolization therapy, a material is injected into a vessel to block blood flow. While this therapy is useful in starving cancerous cells it can be dangerous, with some blockades in the brain dislodging and causing strokes or blindness. Currently, embolic materials on the market such as metal coils, balloons, and liquid embolic agents do not have a quick removal procedure. An ultrasound cleavable material could be removed in an emergency situation without invasive surgery. The primary goal of this research is to design and synthesize a polymer that can be broken down by high intensity focused ultrasound (HIFU). Initially, we have tested the ultrasound sensitive qualities on PPODA-QT hydrogel, a common embolic agent, but the gel showed no physical change after HIFU exposure. It is theorized that PNIPAAm combined with HIFU sensitive monomers can develop a temperature and ultrasound sensitive embolic agent. In our studies, poly(NIPAAm-co-tBa) had a slight lower critical solution temperature (LCST) change of about 2˚C from before to after HIFU while the study with poly(NIPAAm-co-ACL-BME) and PPODA-QT showed no change in LCST.
ContributorsLein, Karolena (Author) / Vernon, Brent (Thesis director) / Pal, Amrita (Committee member) / Harrington Bioengineering Program (Contributor, Contributor) / Barrett, The Honors College (Contributor)
Created2020-05
164948-Thumbnail Image.png
Description

Alginate microspheres have recently become increasingly popular in the realm of drug delivery for their biocompatibility, nontoxicity, inexpensiveness, among other factors. Recent strict regulations on microsphere size have drastically increased manufacturing cost and waste, even though the effect of size variance on drug delivery and subsequent performance is unclear. If

Alginate microspheres have recently become increasingly popular in the realm of drug delivery for their biocompatibility, nontoxicity, inexpensiveness, among other factors. Recent strict regulations on microsphere size have drastically increased manufacturing cost and waste, even though the effect of size variance on drug delivery and subsequent performance is unclear. If sphere size variance does not significantly affect drug release profiles, it is possible that future ordinances may loosen tolerances in manufacturing to limit waste produced and expenditures. We use a mathematical model developed by Nickel et al. [12], to theoretically predict drug delivery profiles based on sphere size, and correlate the expected release with experimental data. This model considers diffusion as the key component for drug delivery, which is defined by Fick’s Laws of Diffusion. Alginate, chosen for its simple fabrication method and biocompatibility, was formed into microspheres with a modified extrusion technique and characterized by size. Size variance was introduced in batches and delivery patterns were compared to control groups of identical size. Release patterns for brilliant blue dye, the mock drug chosen, were examined for both groups via UV spectrometry. The absorbance values were then converted to concentration value using a calibration curve done prior to experimentation. The concentration values were then converted to mass values. These values then produced curves representing the mass of the drug released over time. Although the control and experimental values were statistically significantly different, the curves were rather similar to each other. However, when compared to the predicted release pattern, the curves were not the same. Unexpected degradation caused this dissimilarity between the curves. The predictive model was then adjusted to account for degradation by changing the diffusion coefficient in the code to a reciprocal first order exponent. The similarity between the control and experimental curves can insinuate the notion that size tolerances for microsphere production can be somewhat lenient, as a batch containing fifteen beads of the same size and one with three different sizes yields similar release patterns.

ContributorsLyons, Quincy (Author) / de la Rocha, Gabriel (Co-author) / Vernon, Brent (Thesis director) / Pal, Amrita (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2022-05
164949-Thumbnail Image.png
Description
Alginate microspheres have recently become increasingly popular in the realm of drug delivery for their biocompatibility, nontoxicity, inexpensiveness, among other factors. Recent strict regulations on microsphere size have drastically increased manufacturing cost and waste, even though the effect of size variance on drug delivery and subsequent performance is unclear.

Alginate microspheres have recently become increasingly popular in the realm of drug delivery for their biocompatibility, nontoxicity, inexpensiveness, among other factors. Recent strict regulations on microsphere size have drastically increased manufacturing cost and waste, even though the effect of size variance on drug delivery and subsequent performance is unclear. If sphere size variance does not significantly affect drug release profiles, it is possible that future ordinances may loosen tolerances in manufacturing to limit waste produced and expenditures. We use a mathematical model developed by Nickel et al. [12], to theoretically predict drug delivery profiles based on sphere size, and correlate the expected release with experimental data. This model considers diffusion as the key component for drug delivery, which is defined by Fick’s Laws of Diffusion. Alginate, chosen for its simple fabrication method and biocompatibility, was formed into microspheres with a modified extrusion technique and characterized by size. Size variance was introduced in batches and delivery patterns were compared to control groups of identical size. Release patterns for brilliant blue dye, the mock drug chosen, were examined for both groups via UV spectrometry. The absorbance values were then converted to concentration value using a calibration curve done prior to experimentation. The concentration values were then converted to mass values. These values then produced curves representing the mass of the drug released over time. Although the control and experimental values were statistically significantly different, the curves were rather similar to each other. However, when compared to the predicted release pattern, the curves were not the same. Unexpected degradation caused this dissimilarity between the curves. The predictive model was then adjusted to account for degradation by changing the diffusion coefficient in the code to a reciprocal first order exponent. The similarity between the control and experimental curves can insinuate the notion that size tolerances for microsphere production can be somewhat lenient, as a batch containing fifteen beads of the same size and one with three different sizes yields similar release patterns.
Contributorsde la Rocha, Gabriel (Author) / Lyons, Quincy (Co-author) / Vernon, Brent (Thesis director) / Pal, Amrita (Committee member) / Barrett, The Honors College (Contributor) / Harrington Bioengineering Program (Contributor)
Created2022-05