Matching Items (1,013)
130310-Thumbnail Image.png
Description
The 1958 Nobel prize to Beadle and Tatum for proposing that each gene is responsible for a distinct enzyme is now seen as both foundational to molecular biology and genetics, albeit oversimplified. Some genes, for example, code for functional RNAs, while others code for non-enzymatic proteins such as collagen. Yet

The 1958 Nobel prize to Beadle and Tatum for proposing that each gene is responsible for a distinct enzyme is now seen as both foundational to molecular biology and genetics, albeit oversimplified. Some genes, for example, code for functional RNAs, while others code for non-enzymatic proteins such as collagen. Yet enzymes remain fundamental to life on earth, catalyzing at least 5000 biochemical reactions (so far identified). Enzymes can increase reaction rates by huge factors, from millions of years to milliseconds per event, so that, from meat tenderizer to washing powder, to muscle contraction, cargo transport in the cell, ion pumps, infection and digestion, no molecular machine is more fundamental to biological function than the enzyme.
ContributorsSpence, John (Author) / Lattman, Eaton (Author) / College of Liberal Arts and Sciences (Contributor) / Department of Physics (Contributor)
Created2016-07
130309-Thumbnail Image.png
Description
Lipidic cubic phases (LCPs) have emerged as successful matrixes for the crystallization of membrane proteins. Moreover, the viscous LCP also provides a highly effective delivery medium for serial femtosecond crystallography (SFX) at X-ray free-electron lasers (XFELs). Here, the adaptation of this technology to perform serial millisecond crystallography (SMX) at more

Lipidic cubic phases (LCPs) have emerged as successful matrixes for the crystallization of membrane proteins. Moreover, the viscous LCP also provides a highly effective delivery medium for serial femtosecond crystallography (SFX) at X-ray free-electron lasers (XFELs). Here, the adaptation of this technology to perform serial millisecond crystallography (SMX) at more widely available synchrotron microfocus beamlines is described. Compared with conventional microcrystallography, LCP-SMX eliminates the need for difficult handling of individual crystals and allows for data collection at room temperature. The technology is demonstrated by solving a structure of the light-driven proton-pump bacteriorhodopsin (bR) at a resolution of 2.4 Å. The room-temperature structure of bR is very similar to previous cryogenic structures but shows small yet distinct differences in the retinal ligand and proton-transfer pathway.
ContributorsNogly, Przemyslaw (Author) / James, Daniel (Author) / Wang, Dingjie (Author) / White, Thomas A. (Author) / Zatsepin, Nadia (Author) / Shilova, Anastasya (Author) / Nelson, Garrett (Author) / Liu, Haiguang (Author) / Johansson, Linda (Author) / Heymann, Michael (Author) / Jaeger, Kathrin (Author) / Metz, Markus (Author) / Wickstrand, Cecilia (Author) / Wu, Wenting (Author) / Bath, Petra (Author) / Berntsen, Peter (Author) / Oberthuer, Dominik (Author) / Panneels, Valerie (Author) / Cherezov, Vadim (Author) / Chapman, Henry (Author) / Schertler, Gebhard (Author) / Neutze, Richard (Author) / Spence, John (Author) / Moraes, Isabel (Author) / Burghammer, Manfred (Author) / Standfuss, Joerg (Author) / Weierstall, Uwe (Author) / College of Liberal Arts and Sciences (Contributor) / Department of Physics (Contributor)
Created2015-01-27
130308-Thumbnail Image.png
Description
Serial femtosecond crystallography (SFX) has opened a new era in crystallo­graphy by permitting nearly damage-free, room-temperature structure determination of challenging proteins such as membrane proteins. In SFX, femtosecond X-ray free-electron laser pulses produce diffraction snapshots from nanocrystals and microcrystals delivered in a liquid jet, which leads to high protein consumption.

Serial femtosecond crystallography (SFX) has opened a new era in crystallo­graphy by permitting nearly damage-free, room-temperature structure determination of challenging proteins such as membrane proteins. In SFX, femtosecond X-ray free-electron laser pulses produce diffraction snapshots from nanocrystals and microcrystals delivered in a liquid jet, which leads to high protein consumption. A slow-moving stream of agarose has been developed as a new crystal delivery medium for SFX. It has low background scattering, is compatible with both soluble and membrane proteins, and can deliver the protein crystals at a wide range of temperatures down to 4°C. Using this crystal-laden agarose stream, the structure of a multi-subunit complex, phycocyanin, was solved to 2.5 Å resolution using 300 µg of microcrystals embedded into the agarose medium post-crystallization. The agarose delivery method reduces protein consumption by at least 100-fold and has the potential to be used for a diverse population of proteins, including membrane protein complexes.
ContributorsConrad, Chelsie (Author) / Basu, Shibom (Author) / James, Daniel (Author) / Wang, Dingjie (Author) / Schaffer, Alexander (Author) / Roy Chowdhury, Shatabdi (Author) / Zatsepin, Nadia (Author) / Aquila, Andrew (Author) / Coe, Jesse (Author) / Gati, Cornelius (Author) / Hunter, Mark S. (Author) / Koglin, Jason E. (Author) / Kupitz, Christopher (Author) / Nelson, Garrett (Author) / Subramanian, Ganesh (Author) / White, Thomas A. (Author) / Zhao, Yun (Author) / Zook, James (Author) / Boutet, Sebastien (Author) / Cherezov, Vadim (Author) / Spence, John (Author) / Fromme, Raimund (Author) / Weierstall, Uwe (Author) / Fromme, Petra (Author) / Department of Chemistry and Biochemistry (Contributor) / Biodesign Institute (Contributor) / Applied Structural Discovery (Contributor) / College of Liberal Arts and Sciences (Contributor) / Department of Physics (Contributor) / School of Molecular Sciences (Contributor)
Created2015-06-30
130307-Thumbnail Image.png
Description
Recently we have seen rapid progress in the serial crystallography (SC) method at X-ray free-electron lasers (XFELs). Injection of thousands of protein microcrystals into the ∼10[superscript 12] photons of few-femtosecond XFEL pulses has allowed the structure determination of crystals grown in vivo, or of submicron size, and from challenging targets

Recently we have seen rapid progress in the serial crystallography (SC) method at X-ray free-electron lasers (XFELs). Injection of thousands of protein microcrystals into the ∼10[superscript 12] photons of few-femtosecond XFEL pulses has allowed the structure determination of crystals grown in vivo, or of submicron size, and from challenging targets such as membrane proteins. For time-resolved studies, the small crystal size allows for rapid diffusive saturation in mix-and-inject analysis of biochemical reactions, and full optical saturation of the sample by a pump laser in studies of light-driven proteins. The ability to outrun most radiation damage avoids the need for sample cooling and its artifacts, allowing studies of molecular machines at work in their correct room-temperature thermal bath or a controlled chemical environment.
ContributorsStandfuss, Jorg (Author) / Spence, John (Author) / College of Liberal Arts and Sciences (Contributor) / Department of Physics (Contributor)
Created2017-03
130306-Thumbnail Image.png
Description
Serial femtosecond crystallography (SFX) at X-ray free-electron lasers (XFELs) enables high-resolution protein structure determination using micrometre-sized crystals at room temperature with minimal effects from radiation damage. SFX requires a steady supply of microcrystals intersecting the XFEL beam at random orientations. An LCP–SFX method has recently been introduced in which microcrystals

Serial femtosecond crystallography (SFX) at X-ray free-electron lasers (XFELs) enables high-resolution protein structure determination using micrometre-sized crystals at room temperature with minimal effects from radiation damage. SFX requires a steady supply of microcrystals intersecting the XFEL beam at random orientations. An LCP–SFX method has recently been introduced in which microcrystals of membrane proteins are grown and delivered for SFX data collection inside a gel-like membrane-mimetic matrix, known as lipidic cubic phase (LCP), using a special LCP microextrusion injector. Here, it is demonstrated that LCP can also be used as a suitable carrier medium for microcrystals of soluble proteins, enabling a dramatic reduction in the amount of crystallized protein required for data collection compared with crystals delivered by liquid injectors. High-quality LCP–SFX data sets were collected for two soluble proteins, lysozyme and phycocyanin, using less than 0.1 mg of each protein.
ContributorsFromme, Raimund (Author) / Ishchenko, Andrii (Author) / Metz, Markus (Author) / Roy Chowdhury, Shatabdi (Author) / Basu, Shibom (Author) / Boutet, Sebastien (Author) / Fromme, Petra (Author) / White, Thomas A. (Author) / Barty, Anton (Author) / Spence, John (Author) / Weierstall, Uwe (Author) / Liu, Wei (Author) / Cherezov, Vadim (Author) / Biodesign Institute (Contributor) / Applied Structural Discovery (Contributor) / College of Liberal Arts and Sciences (Contributor) / Department of Physics (Contributor)
Created2015-08-04
130304-Thumbnail Image.png
Description
We compare three schemes for time-resolved X-ray diffraction from protein nanocrystals using an X-ray free-electron laser. We find expressions for the errors in structure factor measurement using the Monte Carlo pump-probe method of data analysis with a liquid jet, the fixed sample pump-probe (goniometer) method (both diffract-and-destroy, and below the

We compare three schemes for time-resolved X-ray diffraction from protein nanocrystals using an X-ray free-electron laser. We find expressions for the errors in structure factor measurement using the Monte Carlo pump-probe method of data analysis with a liquid jet, the fixed sample pump-probe (goniometer) method (both diffract-and-destroy, and below the safe damage dose), and a proposed two-color method. Here, an optical pump pulse arrives between X-ray pulses of slightly different energies which hit the same nanocrystal, using a weak first X-ray pulse which does not damage the sample. (Radiation damage is outrun in the other cases.) This two-color method, in which separated Bragg spots are impressed on the same detector readout, eliminates stochastic fluctuations in crystal size, shape, and orientation and is found to require two orders of magnitude fewer diffraction patterns than the currently used Monte Carlo liquid jet method, for 1% accuracy. Expressions are given for errors in structure factor measurement for the four approaches, and detailed simulations provided for cathepsin B and IC3 crystals. While the error is independent of the number of shots for the dose-limited goniometer method, it falls off inversely as the square root of the number of shots for the two-color and Monte Carlo methods, with a much smaller pre-factor for the two-color mode, when the first shot is below the damage threshold.
ContributorsLi, Chufeng (Author) / Schmidt, Kevin (Author) / Spence, John (Author) / College of Liberal Arts and Sciences (Contributor) / Department of Physics (Contributor)
Created2015-06-12
130303-Thumbnail Image.png
Description
Serial femtosecond crystallography (SFX) using X-ray free-electron lasers has produced high-resolution, room temperature, time-resolved protein structures. We report preliminary SFX of Sindbis virus, an enveloped icosahedral RNA virus with ∼700 Å diameter. Microcrystals delivered in viscous agarose medium diffracted to ∼40 Å resolution. Small-angle diffuse X-ray scattering overlaid Bragg peaks and analysis

Serial femtosecond crystallography (SFX) using X-ray free-electron lasers has produced high-resolution, room temperature, time-resolved protein structures. We report preliminary SFX of Sindbis virus, an enveloped icosahedral RNA virus with ∼700 Å diameter. Microcrystals delivered in viscous agarose medium diffracted to ∼40 Å resolution. Small-angle diffuse X-ray scattering overlaid Bragg peaks and analysis suggests this results from molecular transforms of individual particles. Viral proteins undergo structural changes during entry and infection, which could, in principle, be studied with SFX. This is an important step toward determining room temperature structures from virus microcrystals that may enable time-resolved studies of enveloped viruses.
ContributorsLawrence, Robert (Author) / Conrad, Chelsie (Author) / Zatsepin, Nadia (Author) / Grant, Thomas D. (Author) / Liu, Haiguang (Author) / James, Daniel (Author) / Nelson, Garrett (Author) / Subramanian, Ganesh (Author) / Aquila, Andrew (Author) / Hunter, Mark S. (Author) / Liang, Mengning (Author) / Boutet, Sebastien (Author) / Coe, Jesse (Author) / Spence, John (Author) / Weierstall, Uwe (Author) / Liu, Wei (Author) / Fromme, Petra (Author) / Cherezov, Vadim (Author) / Hogue, Brenda (Author) / Biodesign Institute (Contributor) / Infectious Diseases and Vaccinology (Contributor) / Applied Structural Discovery (Contributor) / Department of Chemistry and Biochemistry (Contributor) / College of Liberal Arts and Sciences (Contributor) / Department of Physics (Contributor) / School of Life Sciences (Contributor)
Created2015-08-20
130302-Thumbnail Image.png
Description
Mix-and-inject serial crystallography (MISC) is a technique designed to image enzyme catalyzed reactions in which small protein crystals are mixed with a substrate just prior to being probed by an X-ray pulse. This approach offers several advantages over flow cell studies. It provides (i) room temperature structures at near atomic

Mix-and-inject serial crystallography (MISC) is a technique designed to image enzyme catalyzed reactions in which small protein crystals are mixed with a substrate just prior to being probed by an X-ray pulse. This approach offers several advantages over flow cell studies. It provides (i) room temperature structures at near atomic resolution, (ii) time resolution ranging from microseconds to seconds, and (iii) convenient reaction initiation. It outruns radiation damage by using femtosecond X-ray pulses allowing damage and chemistry to be separated. Here, we demonstrate that MISC is feasible at an X-ray free electron laser by studying the reaction of M. tuberculosis ß-lactamase microcrystals with ceftriaxone antibiotic solution. Electron density maps of the apo-ß-lactamase and of the ceftriaxone bound form were obtained at 2.8 Å and 2.4 Å resolution, respectively. These results pave the way to study cyclic and non-cyclic reactions and represent a new field of time-resolved structural dynamics for numerous substrate-triggered biological reactions.
ContributorsKupitz, Christopher (Author) / Olmos, Jose L. (Author) / Holl, Mark (Author) / Tremblay, Lee (Author) / Pande, Kanupriya (Author) / Pandey, Suraj (Author) / Oberthur, Dominik (Author) / Hunter, Mark (Author) / Liang, Mengning (Author) / Aquila, Andrew (Author) / Tenboer, Jason (Author) / Calvey, George (Author) / Katz, Andrea (Author) / Chen, Yujie (Author) / Wiedorn, Max O. (Author) / Knoska, Juraj (Author) / Meents, Alke (Author) / Majriani, Valerio (Author) / Norwood, Tyler (Author) / Poudyal, Ishwor (Author) / Grant, Thomas (Author) / Miller, Mitchell D. (Author) / Xu, Weijun (Author) / Tolstikova, Aleksandra (Author) / Morgan, Andrew (Author) / Metz, Markus (Author) / Martin Garcia, Jose Manuel (Author) / Zook, James (Author) / Roy Chowdhury, Shatabdi (Author) / Coe, Jesse (Author) / Nagaratnam, Nirupa (Author) / Meza-Aguilar, Domingo (Author) / Fromme, Raimund (Author) / Basu, Shibom (Author) / Frank, Matthias (Author) / White, Thomas (Author) / Barty, Anton (Author) / Bajt, Sasa (Author) / Yefanov, Oleksandr (Author) / Chapman, Henry N. (Author) / Zatsepin, Nadia (Author) / Nelson, Garrett (Author) / Weierstall, Uwe (Author) / Spence, John (Author) / Schwander, Peter (Author) / Pollack, Lois (Author) / Fromme, Petra (Author) / Ourmazd, Abbas (Author) / Phillips, George N. (Author) / Schmidt, Marius (Author) / College of Liberal Arts and Sciences (Contributor) / Department of Physics (Contributor) / School of Molecular Sciences (Contributor) / Biodesign Institute (Contributor) / Applied Structural Discovery (Contributor)
Created2016-12-15
130301-Thumbnail Image.png
Description
Serial femtosecond crystallography (SFX) takes advantage of extremely bright and ultrashort pulses produced by x-ray free-electron lasers (XFELs), allowing for the collection of high-resolution diffraction intensities from micrometer-sized crystals at room temperature with minimal radiation damage, using the principle of “diffraction-before-destruction.” However, de novo structure factor phase determination using XFELs

Serial femtosecond crystallography (SFX) takes advantage of extremely bright and ultrashort pulses produced by x-ray free-electron lasers (XFELs), allowing for the collection of high-resolution diffraction intensities from micrometer-sized crystals at room temperature with minimal radiation damage, using the principle of “diffraction-before-destruction.” However, de novo structure factor phase determination using XFELs has been difficult so far. We demonstrate the ability to solve the crystallographic phase problem for SFX data collected with an XFEL using the anomalous signal from native sulfur atoms, leading to a bias-free room temperature structure of the human A[subscript 2A] adenosine receptor at 1.9 Å resolution. The advancement was made possible by recent improvements in SFX data analysis and the design of injectors and delivery media for streaming hydrated microcrystals. This general method should accelerate structural studies of novel difficult-to-crystallize macromolecules and their complexes.
ContributorsBatyuk, Alexander (Author) / Galli, Lorenzo (Author) / Ishchenko, Andrii (Author) / Han, Gye Won (Author) / Gati, Cornelius (Author) / Popov, Petr A. (Author) / Lee, Ming-Yue (Author) / Stauch, Benjamin (Author) / White, Thomas A. (Author) / Barty, Anton (Author) / Aquila, Andrew (Author) / Hunter, Mark S. (Author) / Liang, Mengning (Author) / Boutet, Sebastien (Author) / Pu, Mengchen (Author) / Liu, Zhi-jie (Author) / Nelson, Garrett (Author) / James, Daniel (Author) / Li, Chufeng (Author) / Zhao, Yun (Author) / Spence, John (Author) / Liu, Wei (Author) / Fromme, Petra (Author) / Katritch, Vsevolod (Author) / Weierstall, Uwe (Author) / Stevens, Raymond C. (Author) / Cherezov, Vadim (Author) / College of Liberal Arts and Sciences (Contributor) / Department of Physics (Contributor) / Biodesign Institute (Contributor) / Applied Structural Discovery (Contributor) / School of Molecular Sciences (Contributor)
Created2016-09-23
130299-Thumbnail Image.png
Description
Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum

Intense femtosecond x-ray pulses from free-electron laser sources allow the imaging of individual particles in a single shot. Early experiments at the Linac Coherent Light Source (LCLS) have led to rapid progress in the field and, so far, coherent diffractive images have been recorded from biological specimens, aerosols, and quantum systems with a few-tens-of-nanometers resolution. In March 2014, LCLS held a workshop to discuss the scientific and technical challenges for reaching the ultimate goal of atomic resolution with single-shot coherent diffractive imaging. This paper summarizes the workshop findings and presents the roadmap toward reaching atomic resolution, 3D imaging at free-electron laser sources.
ContributorsAquila, A. (Author) / Barty, A. (Author) / Bostedt, C. (Author) / Boutet, S. (Author) / Carini, G. (Author) / dePonte, D. (Author) / Drell, P. (Author) / Doniach, S. (Author) / Downing, K. H. (Author) / Earnest, T. (Author) / Elmlund, H. (Author) / Elser, V. (Author) / Guhr, M. (Author) / Hajdu, J. (Author) / Hastings, J. (Author) / Hau-Riege, S. P. (Author) / Huang, Z. (Author) / Lattman, E. E. (Author) / Maia, F. R. N. C. (Author) / Marchesini, S. (Author) / Ourmazd, A. (Author) / Pellegrini, C. (Author) / Santra, R. (Author) / Schlichting, I. (Author) / Schroer, C. (Author) / Spence, John (Author) / Vartanyants, I. A. (Author) / Wakatsuki, S. (Author) / Weis, W. I. (Author) / Williams, G. J. (Author) / College of Liberal Arts and Sciences (Contributor) / Department of Physics (Contributor)
Created2015-04-21