Humans desire compliant robots to safely interact in dynamic environments
associated with daily activities. As surface electromyography non-invasively measures
limb motion intent and correlates with joint stiness during co-contractions,
it has been identied as a candidate for naturally controlling such robots. However,
state-of-the-art myoelectric interfaces have struggled to achieve both enhanced
functionality and long-term reliability. As demands in myoelectric interfaces trend
toward simultaneous and proportional control of compliant robots, robust processing
of multi-muscle coordinations, or synergies, plays a larger role in the success of the
control scheme. This dissertation presents a framework enhancing the utility of myoelectric
interfaces by exploiting motor skill learning and
exible muscle synergies for
reliable long-term simultaneous and proportional control of multifunctional compliant
robots. The interface is learned as a new motor skill specic to the controller,
providing long-term performance enhancements without requiring any retraining or
recalibration of the system. Moreover, the framework oers control of both motion
and stiness simultaneously for intuitive and compliant human-robot interaction. The
framework is validated through a series of experiments characterizing motor learning
properties and demonstrating control capabilities not seen previously in the literature.
The results validate the approach as a viable option to remove the trade-o
between functionality and reliability that have hindered state-of-the-art myoelectric
interfaces. Thus, this research contributes to the expansion and enhancement of myoelectric
controlled applications beyond commonly perceived anthropomorphic and
\intuitive control" constraints and into more advanced robotic systems designed for
everyday tasks.
One of the hottest topics in rehabilitation robotics is that of proper control of prosthetic devices. Despite decades of research, the state of the art is dramatically behind the expectations. To shed light on this issue, in June, 2013 the first international workshop on Present and future of non-invasive peripheral nervous system (PNS)–Machine Interfaces (MI; PMI) was convened, hosted by the International Conference on Rehabilitation Robotics. The keyword PMI has been selected to denote human–machine interfaces targeted at the limb-deficient, mainly upper-limb amputees, dealing with signals gathered from the PNS in a non-invasive way, that is, from the surface of the residuum. The workshop was intended to provide an overview of the state of the art and future perspectives of such interfaces; this paper represents is a collection of opinions expressed by each and every researcher/group involved in it.