Matching Items (50)
Filtering by

Clear all filters

154425-Thumbnail Image.png
Description
Digital systems are essential to the technological advancements in space exploration. Microprocessor and flash memory are the essential parts of such a digital system. Space exploration requires a special class of radiation hardened microprocessors and flash memories, which are not functionally disrupted in the presence of radiation. The reference design

Digital systems are essential to the technological advancements in space exploration. Microprocessor and flash memory are the essential parts of such a digital system. Space exploration requires a special class of radiation hardened microprocessors and flash memories, which are not functionally disrupted in the presence of radiation. The reference design ‘HERMES’ is a radiation-hardened microprocessor with performance comparable to commercially available designs. The reference design ‘eFlash’ is a prototype of soft-error hardened flash memory for configuring Xilinx FPGAs. These designs are manufactured using a foundry bulk CMOS 90-nm low standby power (LP) process. This thesis presents the post-silicon validation results of these designs.
ContributorsGogulamudi, Anudeep Reddy (Author) / Clark, Lawrence T (Thesis advisor) / Holbert, Keith E. (Committee member) / Brunhaver, John (Committee member) / Arizona State University (Publisher)
Created2016
154405-Thumbnail Image.png
Description
With the growing importance of underground power systems and the need for greater reliability of the power supply, cable monitoring and accurate fault location detection has become an increasingly important issue. The presence of inherent random fluctuations in power system signals can be used to extract valuable information about the

With the growing importance of underground power systems and the need for greater reliability of the power supply, cable monitoring and accurate fault location detection has become an increasingly important issue. The presence of inherent random fluctuations in power system signals can be used to extract valuable information about the condition of system equipment. One such component is the power cable, which is the primary focus of this research.

This thesis investigates a unique methodology that allows online monitoring of an underground power cable. The methodology analyzes conventional power signals in the frequency domain to monitor the condition of a power cable.

First, the proposed approach is analyzed theoretically with the help of mathematical computations. Frequency domain analysis techniques are then used to compute the power spectral density (PSD) of the system signals. The importance of inherent noise in the system, a key requirement of this methodology, is also explained. The behavior of resonant frequencies, which are unique to every system, are then analyzed under different system conditions with the help of mathematical expressions.

Another important aspect of this methodology is its ability to accurately estimate cable fault location. The process is online and hence does not require the system to be disconnected from the grid. A single line to ground fault case is considered and the trend followed by the resonant frequencies for different fault positions is observed.

The approach is initially explained using theoretical calculations followed by simulations in MATLAB/Simulink. The validity of this technique is proved by comparing the results obtained from theory and simulation to actual measurement data.
ContributorsGovindarajan, Sudarshan (Author) / Holbert, Keith E. (Thesis advisor) / Heydt, Gerald (Committee member) / Karady, George G. (Committee member) / Arizona State University (Publisher)
Created2016
154055-Thumbnail Image.png
Description
The electromagnetic fields near power lines that may produce adverse effects on humans are of increasing interest in a variety of situations, thus making it worthwhile to develop general-purpose software that estimates both the electric and magnetic fields accurately. This study deals with the simulations of the electric and magnetic

The electromagnetic fields near power lines that may produce adverse effects on humans are of increasing interest in a variety of situations, thus making it worthwhile to develop general-purpose software that estimates both the electric and magnetic fields accurately. This study deals with the simulations of the electric and magnetic fields near high-voltage power lines for the triangular, horizontal and vertical conductor arrangements under both balanced and unbalanced conditions.

For all three conductor arrangements, the shapes of the electric field distribution curves are different with the vertical arrangement best for minimizing right of way consideration, while the shapes of the magnetic field distributions curves are similar. Except for the horizontal arrangement, the maximum electric field magnitudes with shield conductors are larger than those without shield conductors. Among the three different arrangements, the maximum field value of the vertical arrangement is most vulnerable to the unbalanced conditions.

For both the electric and magnetic fields, increasing the heights of phase conductors gradually results in diminishing return in terms of the field reduction. In this work, both the maximum electric field magnitudes and the maximum magnetic field magnitudes produced by 500 kV power lines at 1 m height from the ground are all within the permissible exposure levels for the general public. At last, the dynamic trajectories of both fields with time are simulated and interpreted, with each field represented by a vector rotating in a plane describing an ellipse, where the vector values can be compared to high-speed vector measurements.
ContributorsXiao, Lei (Author) / Holbert, Keith E. (Thesis advisor) / Karady, George G. (Committee member) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2015
154899-Thumbnail Image.png
Description
Flash memories are critical for embedded devices to operate properly but are susceptible to radiation effects, which make flash memory a key factor to improve the reliability of circuitry. This thesis describes the simulation techniques used to analyze and predict total ionizing dose (TID) effects on 90-nm technology Silicon Storage

Flash memories are critical for embedded devices to operate properly but are susceptible to radiation effects, which make flash memory a key factor to improve the reliability of circuitry. This thesis describes the simulation techniques used to analyze and predict total ionizing dose (TID) effects on 90-nm technology Silicon Storage Technology (SST) SuperFlash Generation 3 devices. Silvaco Atlas is used for both device level design and simulation purposes.

The simulations consist of no radiation and radiation modeling. The no radiation modeling details the cell structure development and characterizes basic operations (read, erase and program) of a flash memory cell. The program time is observed to be approximately 10 μs while the erase time is approximately 0.1 ms.

The radiation modeling uses the fixed oxide charge method to analyze the TID effects on the same flash memory cell. After irradiation, a threshold voltage shift of the flash memory cell is observed. The threshold voltages of a programmed cell and an erased cell are reduced at an average rate of 0.025 V/krad.

The use of simulation techniques allows designers to better understand the TID response of a SST flash memory cell and to predict cell level TID effects without performing the costly in-situ irradiation experiments. The simulation and experimental results agree qualitatively. In particular, simulation results reveal that ‘0’ to ‘1’ errors but not ‘1’ to ‘0’ retention errors occur; likewise, ‘0’ to ‘1’ errors dominate experimental testing, which also includes circuitry effects that can cause ‘1’ to ‘0’ failures. Both simulation and experimental results reveal flash memory cell TID resilience to about 200 krad.
ContributorsChen, Yitao (Author) / Holbert, Keith E. (Thesis advisor) / Clark, Lawrence T. (Committee member) / Allee, David R. (Committee member) / Arizona State University (Publisher)
Created2016
155140-Thumbnail Image.png
Description
In sub transmission systems, many more raptor deaths have been recorded near metal poles rather than wood poles. The metal pole, which is reliable in structure but also grounded, may increase the risk of electrocution when raptors perch on the insulator. This thesis focuses on evaluating the effectiveness of the

In sub transmission systems, many more raptor deaths have been recorded near metal poles rather than wood poles. The metal pole, which is reliable in structure but also grounded, may increase the risk of electrocution when raptors perch on the insulator. This thesis focuses on evaluating the effectiveness of the raptor guard to prevent both debilitating and lethal electrocutions to local wildlife in 69 kV sub transmission systems. First, the two-dimensional (2D) finite difference methods (FDM) were proposed to solve the Poisson and Laplace equations, which describe the electric field. Second, the verification of the FDM algorithm was made based on a parallel-plate capacitor model. Then, the potential and the electric field were simulated by the raptor-insulator model to evaluate the possibility of flashover and leakage current under various conceivable scenarios. Third, several dielectric performance experiments were implemented to gain insight into the physical property of the raptor guard developed by the Salt River Project (SRP) as an example. The proposed initial-tracking-voltage and time-to-track experiments tested the ability of the guard, which is designed to prevent the tracking phenomenon under a contaminated situation such as rain, fog, and snow. A data acquisition also collected the leakage current data for the comparison of maximum raptor tolerance. Furthermore, the puncture voltage of this guard material was performed by the dielectric breakdown voltage experiment in an oil-covered container. With the combination of the model simulation and the experiments in this research, the raptor guard was proven to be practical and beneficial in sub transmission system.
ContributorsShen, Zui (Author) / Gorur, Ravi (Thesis advisor) / Karady, George G. (Committee member) / Holbert, Keith E. (Committee member) / Arizona State University (Publisher)
Created2016
155460-Thumbnail Image.png
Description
On-line dynamic security assessment (DSA) analysis has been developed and applied in several power dispatching control centers. Existing applications of DSA systems are limited by the assumption of the present system operating conditions and computational speeds. To overcome these obstacles, this research developed a novel two-stage DSA system to provide

On-line dynamic security assessment (DSA) analysis has been developed and applied in several power dispatching control centers. Existing applications of DSA systems are limited by the assumption of the present system operating conditions and computational speeds. To overcome these obstacles, this research developed a novel two-stage DSA system to provide periodic security prediction in real time. The major contribution of this research is to develop an open source on-line DSA system incorporated with Phasor Measurement Unit (PMU) data and forecast load. The pre-fault prediction of the system can provide more accurate assessment of the system and minimize the disadvantage of a low computational speed of time domain simulation.

This Thesis describes the development of the novel two-stage on-line DSA scheme using phasor measurement and load forecasting data. The computational scheme of the new system determines the steady state stability and identifies endangerments in a small time frame near real time. The new on-line DSA system will periodically examine system status and predict system endangerments in the near future every 30 minutes. System real-time operating conditions will be determined by state estimation using phasor measurement data. The assessment of transient stability is carried out by running the time-domain simulation using a forecast working point as the initial condition. The forecast operating point is calculated by DC optimal power flow based on forecast load.
ContributorsWang, Qiushi (Author) / Karady, George G. (Thesis advisor) / Pal, Anamitra (Committee member) / Holbert, Keith E. (Committee member) / Arizona State University (Publisher)
Created2017
155761-Thumbnail Image.png
Description
The presence of distributed generation in high renewable energy penetration system increases the complexity for fault detection as the power flow is bidirectional. The conventional protection scheme is not sufficient for the bidirectional power flow system, hence a fast and accurate protection scheme needs to be developed.

This thesis mainly

The presence of distributed generation in high renewable energy penetration system increases the complexity for fault detection as the power flow is bidirectional. The conventional protection scheme is not sufficient for the bidirectional power flow system, hence a fast and accurate protection scheme needs to be developed.

This thesis mainly deals with the design and validation of the protection system based on the Future Renewable Electric Energy Delivery and Management (FREEDM) system, which is a bidirectional power flow loop system. The Large-Scale System Simulation (LSSS) is a system level PSCAD model which is used to validate component models for different time-scale platforms to provide a virtual testing platform for the Future Renewable Electric Energy Delivery and Management (FREEDM) system. It is also used to validate the cases of power system protection, renewable energy integration and storage, and load profiles. The protection of the FREEDM system against any abnormal condition is one of the important tasks. Therefore, the pilot directional protection scheme based on wireless communication is used in this thesis. The use of wireless communication is extended to protect the large scale meshed distributed generation from any fault. The complete protection system consists of the main protection and the back-up protection which are both presented in the thesis. The validation of the protection system is performed on a radial system test bed using commercial relays at the ASU power laboratory, and on the RTDS platform (Real Time Digital Power System) in CAPS (Center for Advanced Power System) Florida. Considering that the commercial relays have limitations of high cost and communicating with fault isolation devices, a hardware prototype using the interface between the ADC (analog to digital converter) and MATLAB software is developed, which takes advantage of economic efficiency and communication compatibility. Part of this research work has been written into a conference paper which was presented by IEEE Green Tech Meeting, 2017.
ContributorsTang, Zhenming (Author) / Karady, George G. (Thesis advisor) / Holbert, Keith E. (Committee member) / Qin, Jiangchao (Committee member) / Arizona State University (Publisher)
Created2017
155707-Thumbnail Image.png
Description
This thesis describes the design of a Single Event Transient (SET) duration measurement test-structure on the Global Foundries (previously IBM) 32-nm silicon-on insulator (SOI) process. The test structure is designed for portability and allows quick design and implementation on a new process node. Such a test structure is critical in

This thesis describes the design of a Single Event Transient (SET) duration measurement test-structure on the Global Foundries (previously IBM) 32-nm silicon-on insulator (SOI) process. The test structure is designed for portability and allows quick design and implementation on a new process node. Such a test structure is critical in analyzing the effects of radiation on complementary metal oxide semi-conductor (CMOS) circuits. The focus of this thesis is the change in pulse width during propagation of SET pulse and build a test structure to measure the duration of a SET pulse generated in real time. This test structure can estimate the SET pulse duration with 10ps resolution. It receives the input SET propagated through a SET capture structure made using a chain of combinational gates. The impact of propagation of the SET in a >200 deep collection structure is studied. A novel methodology of deploying Thick Gate TID structure is proposed and analyzed to build multi-stage chain of combinational gates. Upon using long chain of combinational gates, the most critical issue of pulse width broadening and shortening is analyzed across critical process corners. The impact of using regular standard cells on pulse width modification is compared with NMOS and/or PMOS skewed gates for the chain of combinational gates. A possible resolution to pulse width change is demonstrated using circuit and layout design of chain of inverters, two and three inputs NOR gates. The SET capture circuit is also tested in simulation by introducing a glitch signal that mimics an individual ion strike that could lead to perturbation in SET propagation. Design techniques and skewed gates are deployed to dampen the glitch that occurs under the effect of radiation. Simulation results, layout structures of SET capture circuit and chain of combinational gates are presented.
ContributorsMasand, Lovish (Author) / Clark, Lawrence (Thesis advisor) / Holbert, Keith E. (Committee member) / Barnaby, Hugh (Committee member) / Arizona State University (Publisher)
Created2017
155547-Thumbnail Image.png
Description
ABSTRACT

For almost a decade now, the Greek economic crisis has crippled the Greek nation and its citizenry. High unemployment rates as well as increased levels of homelessness and suicide are only some of the social repercussions of the collapse of the economic system. While we know much about the impact

ABSTRACT

For almost a decade now, the Greek economic crisis has crippled the Greek nation and its citizenry. High unemployment rates as well as increased levels of homelessness and suicide are only some of the social repercussions of the collapse of the economic system. While we know much about the impact of this crisis on Greek citizens, the literature surrounding the crisis lacks a full range of perspectives and experiences. This project works to fill-in the gaps surrounding the Greek economic crisis and the specific experiences of undocumented, immigrant, domestic workers. Looking at the ways in which these women exist in a constant state of violence, fear, and suffering I identify normalized violence in two main arenas: state/institutional and quotidian/everyday acts. Borrowing from Cecilia Menijvar’s pillars of normalized violence (2011), this work identifies the ways in which state-sponsored bureaucratic violence leads to real suffering and fear exemplified in moments of quotidian violence. Understanding the unique experiences of these women, works to weave together a more nuanced understanding of the impacts of the Greek economic crisis. Along with these moments of violence, this ethnographic inspired project highlights modes of survival, resistance, and resilience employed by these women in response to their violent circumstances.
ContributorsLinos, Viviane (Author) / Durfee, Alesha (Thesis advisor) / Vega, Sujey (Committee member) / Adelman, Madelaine (Committee member) / Arizona State University (Publisher)
Created2017
149658-Thumbnail Image.png
Description
Hydropower generation is one of the clean renewable energies which has received great attention in the power industry. Hydropower has been the leading source of renewable energy. It provides more than 86% of all electricity generated by renewable sources worldwide. Generally, the life span of a hydropower plant is considered

Hydropower generation is one of the clean renewable energies which has received great attention in the power industry. Hydropower has been the leading source of renewable energy. It provides more than 86% of all electricity generated by renewable sources worldwide. Generally, the life span of a hydropower plant is considered as 30 to 50 years. Power plants over 30 years old usually conduct a feasibility study of rehabilitation on their entire facilities including infrastructure. By age 35, the forced outage rate increases by 10 percentage points compared to the previous year. Much longer outages occur in power plants older than 20 years. Consequently, the forced outage rate increases exponentially due to these longer outages. Although these long forced outages are not frequent, their impact is immense. If reasonable timing of rehabilitation is missed, an abrupt long-term outage could occur and additional unnecessary repairs and inefficiencies would follow. On the contrary, too early replacement might cause the waste of revenue. The hydropower plants of Korea Water Resources Corporation (hereafter K-water) are utilized for this study. Twenty-four K-water generators comprise the population for quantifying the reliability of each equipment. A facility in a hydropower plant is a repairable system because most failures can be fixed without replacing the entire facility. The fault data of each power plant are collected, within which only forced outage faults are considered as raw data for reliability analyses. The mean cumulative repair functions (MCF) of each facility are determined with the failure data tables, using Nelson's graph method. The power law model, a popular model for a repairable system, can also be obtained to represent representative equipment and system availability. The criterion-based analysis of HydroAmp is used to provide more accurate reliability of each power plant. Two case studies are presented to enhance the understanding of the availability of each power plant and represent economic evaluations for modernization. Also, equipment in a hydropower plant is categorized into two groups based on their reliability for determining modernization timing and their suitable replacement periods are obtained using simulation.
ContributorsKwon, Ogeuk (Author) / Holbert, Keith E. (Thesis advisor) / Heydt, Gerald T (Committee member) / Pan, Rong (Committee member) / Arizona State University (Publisher)
Created2011