Matching Items (19)
Filtering by

Clear all filters

152063-Thumbnail Image.png
Description
A cerebral aneurysm is a bulging of a blood vessel in the brain. Aneurysmal rupture affects 25,000 people each year and is associated with a 45% mortality rate. Therefore, it is critically important to treat cerebral aneurysms effectively before they rupture. Endovascular coiling is the most effective treatment for cerebral

A cerebral aneurysm is a bulging of a blood vessel in the brain. Aneurysmal rupture affects 25,000 people each year and is associated with a 45% mortality rate. Therefore, it is critically important to treat cerebral aneurysms effectively before they rupture. Endovascular coiling is the most effective treatment for cerebral aneurysms. During coiling process, series of metallic coils are deployed into the aneurysmal sack with the intent of reaching a sufficient packing density (PD). Coils packing can facilitate thrombus formation and help seal off the aneurysm from circulation over time. While coiling is effective, high rates of treatment failure have been associated with basilar tip aneurysms (BTAs). Treatment failure may be related to geometrical features of the aneurysm. The purpose of this study was to investigate the influence of dome size, parent vessel (PV) angle, and PD on post-treatment aneurysmal hemodynamics using both computational fluid dynamics (CFD) and particle image velocimetry (PIV). Flows in four idealized BTA models with a combination of dome sizes and two different PV angles were simulated using CFD and then validated against PIV data. Percent reductions in post-treatment aneurysmal velocity and cross-neck (CN) flow as well as percent coverage of low wall shear stress (WSS) area were analyzed. In all models, aneurysmal velocity and CN flow decreased after coiling, while low WSS area increased. However, with increasing PD, further reductions were observed in aneurysmal velocity and CN flow, but minimal changes were observed in low WSS area. Overall, coil PD had the greatest impact while dome size has greater impact than PV angle on aneurysmal hemodynamics. These findings lead to a conclusion that combinations of treatment goals and geometric factor may play key roles in coil embolization treatment outcomes, and support that different treatment timing may be a critical factor in treatment optimization.
ContributorsIndahlastari, Aprinda (Author) / Frakes, David (Thesis advisor) / Chong, Brian (Committee member) / Muthuswamy, Jitendran (Committee member) / Arizona State University (Publisher)
Created2013
151787-Thumbnail Image.png
Description
Electromyogram (EMG)-based control interfaces are increasingly used in robot teleoperation, prosthetic devices control and also in controlling robotic exoskeletons. Over the last two decades researchers have come up with a plethora of decoding functions to map myoelectric signals to robot motions. However, this requires a lot of training and validation

Electromyogram (EMG)-based control interfaces are increasingly used in robot teleoperation, prosthetic devices control and also in controlling robotic exoskeletons. Over the last two decades researchers have come up with a plethora of decoding functions to map myoelectric signals to robot motions. However, this requires a lot of training and validation data sets, while the parameters of the decoding function are specific for each subject. In this thesis we propose a new methodology that doesn't require training and is not user-specific. The main idea is to supplement the decoding functional error with the human ability to learn inverse model of an arbitrary mapping function. We have shown that the subjects gradually learned the control strategy and their learning rates improved. We also worked on identifying an optimized control scheme that would be even more effective and easy to learn for the subjects. Optimization was done by taking into account that muscles act in synergies while performing a motion task. The low-dimensional representation of the neural activity was used to control a two-dimensional task. Results showed that in the case of reduced dimensionality mapping, the subjects were able to learn to control the device in a slower pace, however they were able to reach and retain the same level of controllability. To summarize, we were able to build an EMG-based controller for robot devices that would work for any subject, without any training or decoding function, suggesting human-embedded controllers for robotic devices.
ContributorsAntuvan, Chris Wilson (Author) / Artemiadis, Panagiotis (Thesis advisor) / Muthuswamy, Jitendran (Committee member) / Santos, Veronica J (Committee member) / Arizona State University (Publisher)
Created2013
151480-Thumbnail Image.png
Description
The use of electromyography (EMG) signals to characterize muscle fatigue has been widely accepted. Initial work on characterizing muscle fatigue during isometric contractions demonstrated that its frequency decreases while its amplitude increases with the onset of fatigue. More recent work concentrated on developing techniques to characterize dynamic contractions for use

The use of electromyography (EMG) signals to characterize muscle fatigue has been widely accepted. Initial work on characterizing muscle fatigue during isometric contractions demonstrated that its frequency decreases while its amplitude increases with the onset of fatigue. More recent work concentrated on developing techniques to characterize dynamic contractions for use in clinical and training applications. Studies demonstrated that as fatigue progresses, the EMG signal undergoes a shift in frequency, and different physiological mechanisms on the possible cause of the shift were considered. Time-frequency processing, using the Wigner distribution or spectrogram, is one of the techniques used to estimate the instantaneous mean frequency and instantaneous median frequency of the EMG signal using a variety of techniques. However, these time-frequency methods suffer either from cross-term interference when processing signals with multiple components or time-frequency resolution due to the use of windowing. This study proposes the use of the matching pursuit decomposition (MPD) with a Gaussian dictionary to process EMG signals produced during both isometric and dynamic contractions. In particular, the MPD obtains unique time-frequency features that represent the EMG signal time-frequency dependence without suffering from cross-terms or loss in time-frequency resolution. As the MPD does not depend on an analysis window like the spectrogram, it is more robust in applying the timefrequency features to identify the spectral time-variation of the EGM signal.
ContributorsAustin, Hiroko (Author) / Papandreou-Suppappola, Antonia (Thesis advisor) / Kovvali, Narayan (Committee member) / Muthuswamy, Jitendran (Committee member) / Arizona State University (Publisher)
Created2012
152340-Thumbnail Image.png
Description
A noninvasive optical method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm that is a peak absorbance of hemoglobin. As the glucose concentration in the blood decreases, its

A noninvasive optical method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm that is a peak absorbance of hemoglobin. As the glucose concentration in the blood decreases, its osmolarity also decreases and the RBCs swell and decrease the path length absorption coefficient. Decreasing absorption coefficient increases the transmission of light through the whole blood. The system was tested with a constructed optical cell that held whole blood in a capillary tube. As expected the light transmitted to the photodiode increases with decreasing glucose concentration. The average response time of the system was between 30-40 seconds. The changes in size of the RBC cells in response to glucose concentration changes were confirmed using a cell counter and also visually under microscope. This method does not allow measuring the glucose concentration with an absolute concentration calibration. It is directed towards development of a device to monitor the changes in glucose concentration as an aid to diabetic management. This method might be improvised for precision and resolution and be developed as a ring or an earring that patients can wear.
ContributorsRajan, Shiny Amala Priya (Author) / Towe, Bruce (Thesis advisor) / Muthuswamy, Jitendran (Committee member) / LaBelle, Jeffrey (Committee member) / Arizona State University (Publisher)
Created2013
153325-Thumbnail Image.png
Description
The football helmet is a device used to help mitigate the occurrence of impact-related traumatic (TBI) and minor traumatic brain injuries (mTBI) in the game of American football. The current design methodology of using a hard shell with an energy absorbing liner may be adequate for minimizing TBI, however it

The football helmet is a device used to help mitigate the occurrence of impact-related traumatic (TBI) and minor traumatic brain injuries (mTBI) in the game of American football. The current design methodology of using a hard shell with an energy absorbing liner may be adequate for minimizing TBI, however it has had less effect in minimizing mTBI. The latest research in brain injury mechanisms has established that the current design methodology has produced a helmet to reduce linear acceleration of the head. However, angular accelerations also have an adverse effect on the brain response, and must be investigated as a contributor of brain injury.

To help better understand how the football helmet design features effect the brain response during impact, this research develops a validated football helmet model and couples it with a full LS-DYNA human body model developed by the Global Human Body Modeling Consortium (v4.1.1). The human body model is a conglomeration of several validated models of different sections of the body. Of particular interest for this research is the Wayne State University Head Injury Model for modeling the brain. These human body models were validated using a combination of cadaveric and animal studies. In this study, the football helmet was validated by laboratory testing using drop tests on the crown of the helmet. By coupling the two models into one finite element model, the brain response to impact loads caused by helmet design features can be investigated. In the present research, LS-DYNA is used to study a helmet crown impact with a rigid steel plate so as to obtain the strain-rate, strain, and stress experienced in the corpus callosum, midbrain, and brain stem as these anatomical regions are areas of concern with respect to mTBI.
ContributorsDarling, Timothy (Author) / Rajan, Subramaniam D. (Thesis advisor) / Muthuswamy, Jitendran (Thesis advisor) / Oswald, Jay (Committee member) / Mignolet, Marc (Committee member) / Arizona State University (Publisher)
Created2014
150758-Thumbnail Image.png
Description
Microelectrodes have been used as the neural interface to record brain's neural activities. Most of these electrodes are fixed positioned. Neural signal normally degrades over time due to the body immune response and brain micromotion that move the neurons away from the microelectrode. MEMS technology under SUMMiT VTM processes has

Microelectrodes have been used as the neural interface to record brain's neural activities. Most of these electrodes are fixed positioned. Neural signal normally degrades over time due to the body immune response and brain micromotion that move the neurons away from the microelectrode. MEMS technology under SUMMiT VTM processes has developed miniaturized version of moveable microelectrodes that have the ability to recover the neural signal degradation by searching new cluster of neurons. To move the MEMS microelectrode a combination of four voltage waveforms must be applied to four thermally actuated microactuators. Previous design has used OmneticTM interconnect to transfer the waveforms from the external signal generators to the MEMS device. Unfortunately, the mechanism to attach and detach the OmneticTM interconnect introduce mechanical stress into the brain tissue that often caused raptures in the blood vessel. The goal of this project is to create an integrated System-On-Package Signal Generator that can be implanted on the brain of a rodent. A wireless system and a microcontroller are integrated together with the signal generators. The integrated system can be used to generate a series of voltage waveforms that can be customized to drive an array of MEMS movable microelectrodes when a triggered signal is received wirelessly. 3D stacking technique has been used to develop this Integrated System. 3D stacks lead to several favorable factors, such as (a) reduction in the power consumption of the system, (b) reduction in the overall form-factor of the package, and (c) significant reduction the weight of the package. There are a few challenges that must be overcome in this project, such as a commercially available microcontroller normally have an output voltage of 3.3 V to 5.5 V; however, a voltage of 7 - 8V is required to move the MEMS movable microelectrodes. To acquire higher density neural recording, more number of microelectrodes are needed. In this project, SoP Signal Generator is design to drive independently 3 moveable microelectrodes. Therefore, 12 voltage waveform are required. . However, the use of 12 signal generators is not a workable option since the system will be significantly large. This brings us to the other challenge, the limiting size of the rodent brain. Due to this factor, the SoP Signal Generator has to be deisgned to be able to fit without causing much pressure to the rodent's brain. For the first challenge, which is the limited output voltage of 3.3V on the microcontroller, the RC555 timers are used as an amplifier in addition to generating the signals. Demultiplexers have been for the next challenge, which is the need of 24 waveforms to drive 3 electrodes. For each waveform, 1 demultiplexer is used, making a total of 4 demultiplexers used in the entire system, which is a significant improvement from using 12 signal generators. The last challenge can be approached using 3D system stacking technique as mentioned above. The research aims of this project can be described as follows: (1) the testing and realization of the system part, and the designing of the system in a PCB level, (2) implementing and testing the SoP Signal Generator with the MEMS movable microelectrodes, The final outcome of this project can be used not only for neural applications, but also for more general applications that requires customized signal generations and wireless data transmission.
ContributorsTee, Zikai (Author) / Muthuswamy, Jitendran (Thesis advisor) / Sutanto, Jemmy (Committee member) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2012
150768-Thumbnail Image.png
Description
There is a tremendous need for wireless biological signals acquisition for the microelectrode-based neural interface to reduce the mechanical impacts introduced by wire-interconnects system. Long wire connections impede the ability to continuously record the neural signal for chronic application from the rodent's brain. Furthermore, connecting and/or disconnecting Omnetics interconnects often

There is a tremendous need for wireless biological signals acquisition for the microelectrode-based neural interface to reduce the mechanical impacts introduced by wire-interconnects system. Long wire connections impede the ability to continuously record the neural signal for chronic application from the rodent's brain. Furthermore, connecting and/or disconnecting Omnetics interconnects often introduces mechanical stress which causes blood vessel to rupture and leads to trauma to the brain tissue. Following the initial implantation trauma, glial tissue formation around the microelectrode and may possibly lead to the microelectrode signal degradation. The aim of this project is to design, develop, and test a compact and power efficient integrated system (IS) that is able to (a) wirelessly transmit triggering signal from the computer to the signal generator which supplies voltage waveforms that move the MEMS microelectrodes, (b) wirelessly transmit neural data from the brain to the external computer, and (c) provide an electrical interface for a closed loop control to continuously move the microelectrode till a proper quality of neural signal is achieved. One of the main challenges of this project is the limited data transmission rate of the commercially available wireless system to transmit 400 kbps of digitized neural signals/electrode, which include spikes, local field potential (LFP), and noise. A commercially available Bluetooth module is only capable to transmit at a total of 115 kbps data transfer rate. The approach to this challenge is to digitize the analog neural signal with a lower accuracy ADC to lower the data rate, so that is reasonable to wirelessly transfer neural data of one channel. In addition, due to the limited space and weight bearing capability to the rodent's head, a compact and power efficient integrated system is needed to reduce the packaged volume and power consumption. 3D SoP technology has been used to stack the PCBs in a 3D form-factor, proper routing designs and techniques are implemented to reduce the electrical routing resistances and the parasitic RC delay. It is expected that this 3D design will reduce the power consumption significantly in comparison to the 2D one. The progress of this project is divided into three different phases, which can be outlined as follow: a) Design, develop, and test Bluetooth wireless system to transmit the triggering signal from the computer to the signal generator. The system is designed for three moveable microelectrodes. b) Design, develop, and test Bluetooth wireless system to wirelessly transmit an amplified (200 gain) neural signal from one single electrode to an external computer. c) Design, develop, and test a closed loop control system that continuously moves a microelectrode in searching of an acceptable quality of neural spikes. The outcome of this project can be used not only for the need of neural application but also for a wider and general applications that requires customized signal generations and wireless data transmission.
ContributorsZhou, Li (Author) / Muthuswamy, Jitendran (Thesis advisor) / Sutanto, Jemmy (Thesis advisor) / Yu, Hongyu (Committee member) / Arizona State University (Publisher)
Created2012
151058-Thumbnail Image.png
Description
Development of post-traumatic epilepsy (PTE) after traumatic brain injury (TBI) is a major health concern (5% - 50% of TBI cases). A significant problem in TBI management is the inability to predict which patients will develop PTE. Such prediction, followed by timely treatment, could be highly beneficial to TBI patients.

Development of post-traumatic epilepsy (PTE) after traumatic brain injury (TBI) is a major health concern (5% - 50% of TBI cases). A significant problem in TBI management is the inability to predict which patients will develop PTE. Such prediction, followed by timely treatment, could be highly beneficial to TBI patients. Six male Sprague-Dawley rats were subjected to a controlled cortical impact (CCI). A 6mm piston was pneumatically driven 3mm into the right parietal cortex with velocity of 5.5m/s. The rats were subsequently implanted with 6 intracranial electroencephalographic (EEG) electrodes. Long-term (14-week) continuous EEG recordings were conducted. Using linear (coherence) and non-linear (Lyapunov exponents) measures of EEG dynamics in conjunction with measures of network connectivity, we studied the evolution over time of the functional connectivity between brain sites in order to identify early precursors of development of epilepsy. Four of the six TBI rats developed PTE 6 to 10 weeks after the initial insult to the brain. Analysis of the continuous EEG from these rats showed a gradual increase of the connectivity between critical brain sites in terms of their EEG dynamics, starting at least 2 weeks prior to their first spontaneous seizure. In contrast, for the rats that did not develop epilepsy, connectivity levels did not change, or decreased during the whole course of the experiment across pairs of brain sites. Consistent behavior of functional connectivity changes between brain sites and the "focus" (site of impact) over time was demonstrated for coherence in three out of the four epileptic and in both non-epileptic rats, while for STLmax in all four epileptic and in both non-epileptic rats. This study provided us with the opportunity to quantitatively investigate several aspects of epileptogenesis following traumatic brain injury. Our results strongly support a network pathology that worsens with time. It is conceivable that the observed changes in spatiotemporal dynamics after an initial brain insult, and long before the development of epilepsy, could constitute a basis for predictors of epileptogenesis in TBI patients.
ContributorsTobin, Edward (Author) / Iasemidis, Leonidas (Thesis advisor) / Tsakalis, Konstantinos (Committee member) / Muthuswamy, Jitendran (Committee member) / Arizona State University (Publisher)
Created2012
Description
Optical Fibers coupled to laser light sources, and Light Emitting Diodes are the two classes of technologies used for optogenetic experiments. Arizona State University's Flexible Display Center fabricates novel flexible Organic Light Emitting Diodes(OLEDs). These OLEDs have the capability of being monolithically fabricated over flexible, transparent plastic substrates and having

Optical Fibers coupled to laser light sources, and Light Emitting Diodes are the two classes of technologies used for optogenetic experiments. Arizona State University's Flexible Display Center fabricates novel flexible Organic Light Emitting Diodes(OLEDs). These OLEDs have the capability of being monolithically fabricated over flexible, transparent plastic substrates and having power efficient ways of addressing high density arrays of LEDs. This thesis critically evaluates the technology by identifying the key advantages, current limitations and experimentally assessing the technology in in-vivo and in-vitro animal models. For in-vivo testing, the emitted light from a flat OLED panel was directly used to stimulate the neo-cortex in the M1 region of transgenic mice expressing ChR2 (B6.Cg-Tg (Thy1-ChR2/EYFP) 9Gfng/J). An alternative stimulation paradigm using a collimating optical system coupled with an optical fiber was used for stimulating neurons in layer 5 of the motor cortex in the same transgenic mice. EMG activity was recorded from the contralateral vastus lateralis muscles. In vitro testing of the OLEDs was done in primary cortical neurons in culture transfected with blue light sensitive ChR2. The neurons were cultured on a microelectrode array for taking neuronal recordings.
ContributorsShah, Ankur (Author) / Muthuswamy, Jitendran (Thesis advisor) / Greger, Bradley (Committee member) / Blain Christen, Jennifer (Committee member) / Arizona State University (Publisher)
Created2015
153963-Thumbnail Image.png
Description
There is a strong medical need and important therapeutic applications for improved wireless bioelectric interfaces to the nervous system. Multichannel devices are desired for neural control of robotic prosthetics that interface to remaining nerves in limb stumps of amputees and as alternatives to traditional wired arrays used in for some

There is a strong medical need and important therapeutic applications for improved wireless bioelectric interfaces to the nervous system. Multichannel devices are desired for neural control of robotic prosthetics that interface to remaining nerves in limb stumps of amputees and as alternatives to traditional wired arrays used in for some types of brain stimulation. This present work investigates a new approach to ultrasound-powering of implantable microelectronic devices within the tissue that may better support such applications. These devices are of ultra-miniature size that is enabled by a wireless technique. This study investigates two types of ultrasound-powered neural interfaces for multichannel sensory feedback in neurostimulation. The piezoceramics lead zirconate titanate (PZT) ceramic and polyvinylidene fluoride (PVDF) polymer were the primary materials used to build the devices. They convert ultrasound to electricity that when rectified by a diode produce a current output that is neuro stimulatory to peripheral nerve or the neurons in the brain. Multichannel devices employ a form of spatial multiplexing that directs focused ultrasound towards localized and segmented regions of PVDF or PZT that allows independent channels of nerve actuation. Different frequencies of ultrasound were evaluated for best results. Firstly, a 2.25 MHz frequency signal that is reasonably penetrating through body tissue to an implant several centimeters deep and also a 5 MHz frequency more suited to application for actuation of devices within a less than a centimeter of nerve. Results show multichannel device performance to have a complex inter-relationship with frequency, size and thickness, angular incidence, channel separations, and number of folds (layers connected in series and parallel). The output electrical port impedances of PVDF devices were examined in relationship to that of stimulating electrodes and tissue interfaces. Miniature multichannel devices were constructed using an unreported method of employing state of the art laser cutting systems. The results show that PVDF based devices have advantages over PZT, because of better acoustic coupling with tissue, known better biocompatibility, and better separation between multiple channels. However, the PZT devices proved to be better overall in terms of compactness and higher outputs for a given ultrasound power level.
ContributorsNanda Kumar, Yashwanth (Author) / Towe, Bruce (Thesis advisor) / Muthuswamy, Jitendran (Committee member) / Nikkhah, Mehdi (Committee member) / Arizona State University (Publisher)
Created2015