Matching Items (170)

Filtering by

Clear all filters

149447-Thumbnail Image.png
Description

An advantage of doubly fed induction generators (DFIGs) as compared to conventional fixed speed wind turbine generators is higher efficiency. This higher efficiency is achieved due to the ability of the DFIG to operate near its optimal turbine efficiency over a wider range of wind speeds through variable speed operation.

An advantage of doubly fed induction generators (DFIGs) as compared to conventional fixed speed wind turbine generators is higher efficiency. This higher efficiency is achieved due to the ability of the DFIG to operate near its optimal turbine efficiency over a wider range of wind speeds through variable speed operation. This is achieved through the application of a back-to-back converter that tightly controls the rotor current and allows for asynchronous operation. In doing so, however, the power electronic converter effectively decouples the inertia of the turbine from the system. Hence, with the increase in penetration of DFIG based wind farms, the effective inertia of the system will be reduced. With this assertion, the present study is aimed at identifying the systematic approach to pinpoint the impact of increased penetration of DFIGs on a large realistic system. The techniques proposed in this work are tested on a large test system representing the Midwestern portion of the U.S. Interconnection. The electromechanical modes that are both detrimentally and beneficially affected by the change in inertia are identified. The combination of small-signal stability analysis coupled with the large disturbance analysis of exciting the mode identified is found to provide a detailed picture of the impact on the system. The work is extended to develop suitable control strategies to mitigate the impact of significant DFIG penetration on a large power system. Supplementary control is developed for the DFIG power converters such that the effective inertia contributed by these wind generators to the system is increased. Results obtained on the large realistic power system indicate that the frequency nadir following a large power impact is effectively improved with the proposed control strategy. The proposed control is also validated against sudden wind speed changes in the form of wind gusts and wind ramps. The beneficial impact in terms of damping power system oscillations is observed, which is validated by eigenvalue analysis. Another control mechanism is developed aiming at designing the power system stabilizer (PSS) for a DFIG similar to the PSS of synchronous machines. Although both the supplementary control strategies serve the purpose of improving the damping of the mode with detrimental impact, better damping performance is observed when the DFIG is equipped with both the controllers.

ContributorsGautam, Durga (Author) / Vittal, Vijay (Thesis advisor) / Heydt, Gerald (Committee member) / Ayyanar, Raja (Committee member) / Farmer, Richard (Committee member) / Si, Jennie (Committee member) / Arizona State University (Publisher)
Created2010
149394-Thumbnail Image.png
Description

Market acceptability of distributed energy resource (DER) technologies and the gradual and consistent increase in their depth of penetration have generated significant interest over the past few years. In particular, in Arizona and several other states there has been a substantial in-crease in distributed photovoltaic (PV) generation interfaced to the

Market acceptability of distributed energy resource (DER) technologies and the gradual and consistent increase in their depth of penetration have generated significant interest over the past few years. In particular, in Arizona and several other states there has been a substantial in-crease in distributed photovoltaic (PV) generation interfaced to the power distribution systems, and is expected to continue to grow at a significant rate. This has made integration, control and optimal operation of DER units a main area of focus in the design and operation of distribution systems. Grid-connected, distributed PV covers a wide range of power levels ranging from small, single phase residential roof-top systems to large three-phase, multi-megawatt systems. The focus of this work is on analyzing large, three-phase systems, with the power distribution system of the Arizona State University (ASU) Tempe campus used as the test bed for analysis and simulation. The Tempe campus of ASU has presently 4.5 MW of installed PV capacity, with another 4.5 MW expected to be added by 2011, which will represent about 22% of PV penetration. The PV systems are interfaced to the grid invariably by a power electronic inverter. Many of the important characteristics of the PV generation are influenced by the design and performance of the inverter, and hence suitable models of the inverter are needed to analyze PV systems. Several models of distributed generation (DG), including switching and average models, suitable for different study objectives, and different control modes of the inverter have been described in this thesis. A critical function of the inverters is to quickly detect and eliminate unintentional islands during grid failure. In this thesis, many active anti-islanding techniques with voltage and frequency positive feedback have been studied. Effectiveness of these techniques in terms of the tripping times specified in IEEE Std. 1547 for interconnecting distributed resources with electric power systems has been analyzed. The impact of distributed PV on the voltage profile of a distribution system has been ana-lyzed with ASU system as the test bed using power systems analysis tools namely PowerWorld and CYMDIST. The present inverters complying with IEEE 1547 do not regulate the system vol-tage. However, the future inverters especially at higher power levels are expected to perform sev-eral grid support functions including voltage regulation and reactive power support. Hence, the impact of inverters with the reactive power support capabilities is also analyzed. Various test sce-narios corresponding to different grid conditions are simulated and it is shown that distributed PV improves the voltage profile of the system. The improvements are more significant when the PV generators are capable of reactive power support. Detailed short circuit analyses are also per-formed on the system, and the impact of distributed PV on the fault current magnitude, with and without reactive power injection, have been studied.

ContributorsNarayanan, Anand (Author) / Ayyanar, Raja (Thesis advisor) / Vittal, Vijay (Committee member) / Heydt, Gerald T (Committee member) / Arizona State University (Publisher)
Created2010
149406-Thumbnail Image.png
Description

After a power system blackout, system restoration is the most important task for the operators. Most power systems rely on an off&ndashline; restoration plan and the experience of operators to select scenarios for the black start path. Using an off&ndashline; designed restoration plan based on past experience may not be

After a power system blackout, system restoration is the most important task for the operators. Most power systems rely on an off&ndashline; restoration plan and the experience of operators to select scenarios for the black start path. Using an off&ndashline; designed restoration plan based on past experience may not be the most reliable approach under changing network configurations and loading levels. Hence, an objective restoration path selection procedure, including the option to check constraints, may be more responsive in providing directed guidance to the operators to identify the optimal transmission path to deliver power to other power plants or to pick up load as needed. After the system is subjected to a blackout, parallel restoration is an efficient way to speed up the restoration process. For a large scale power system, this system sectionalizing problem is quite complicated when considering black&ndashstart; constraints, generation/load balance constraints and voltage constraints. This dissertation presents an ordered binary decision diagram (OBDD) &ndashbased; system sectionalizing method, by which the splitting points can be quickly found. The simulation results on the IEEE 39 and 118&ndashbus; system show that the method can successfully split the system into subsystems satisfying black&ndashstart; constraints, generation/load balance constraints and voltage constraints. A power transfer distribution factor (PTDF)&ndashbased; approach will be described in this dissertation to check constraints while restoring the system. Two types of restoration performance indices are utilized considering all possible restoration paths, which are then ranked according to their expected performance characteristics as reflected by the restoration performance index. PTDFs and weighting factors are used to determine the ordered list of restoration paths, which can enable the load to be picked up by lightly loaded lines or relieve stress on heavily loaded lines. A transmission path agent can then be formulated by performing the automatic path selection under different system operating conditions. The proposed restoration strategy is tested on the IEEE&ndash39; bus system and on the Western region of the Entergy system. The testing results reveal that the proposed strategy can be used in real time.

ContributorsWang, Chong (Author) / Vittal, Vijay (Thesis advisor) / Tylavsky, Daniel (Committee member) / Heydt, Gerald (Committee member) / Farmer, Richard (Committee member) / Arizona State University (Publisher)
Created2010
153496-Thumbnail Image.png
Description

An important operating aspect of all transmission systems is power system stability

and satisfactory dynamic performance. The integration of renewable resources in general, and photovoltaic resources in particular into the grid has created new engineering issues. A particularly problematic operating scenario occurs when conventional generation is operated at a low level

An important operating aspect of all transmission systems is power system stability

and satisfactory dynamic performance. The integration of renewable resources in general, and photovoltaic resources in particular into the grid has created new engineering issues. A particularly problematic operating scenario occurs when conventional generation is operated at a low level but photovoltaic solar generation is at a high level. Significant solar photovoltaic penetration as a renewable resource is becoming a reality in some electric power systems. In this thesis, special attention is given to photovoltaic generation in an actual electric power system: increased solar penetration has resulted in significant strides towards meeting renewable portfolio standards. The impact of solar generation integration on power system dynamics is studied and evaluated.

This thesis presents the impact of high solar penetration resulting in potentially

problematic low system damping operating conditions. This is the case because the power system damping provided by conventional generation may be insufficient due to reduced system inertia and change in power flow patterns affecting synchronizing and damping capability in the AC system. This typically occurs because conventional generators are rescheduled or shut down to allow for the increased solar production. This problematic case may occur at any time of the year but during the springtime months of March-May, when the system load is low and the ambient temperature is relatively low, there is the potential that over voltages may occur in the high voltage transmission system. Also, reduced damping in system response to disturbances may occur. An actual case study is considered in which real operating system data are used. Solutions to low damping cases are discussed and a solution based on the retuning of a conventional power system stabilizer is given in the thesis.

ContributorsPethe, Anushree Sanjeev (Author) / Vittal, Vijay (Thesis advisor) / Heydt, Gerald T (Thesis advisor) / Ayyanar, Raja (Committee member) / Arizona State University (Publisher)
Created2015
153945-Thumbnail Image.png
Description

Understanding the graphical structure of the electric power system is important

in assessing reliability, robustness, and the risk of failure of operations of this criti-

cal infrastructure network. Statistical graph models of complex networks yield much

insight into the underlying processes that are supported by the network. Such gen-

erative graph models are also

Understanding the graphical structure of the electric power system is important

in assessing reliability, robustness, and the risk of failure of operations of this criti-

cal infrastructure network. Statistical graph models of complex networks yield much

insight into the underlying processes that are supported by the network. Such gen-

erative graph models are also capable of generating synthetic graphs representative

of the real network. This is particularly important since the smaller number of tradi-

tionally available test systems, such as the IEEE systems, have been largely deemed

to be insucient for supporting large-scale simulation studies and commercial-grade

algorithm development. Thus, there is a need for statistical generative models of

electric power network that capture both topological and electrical properties of the

network and are scalable.

Generating synthetic network graphs that capture key topological and electrical

characteristics of real-world electric power systems is important in aiding widespread

and accurate analysis of these systems. Classical statistical models of graphs, such as

small-world networks or Erd}os-Renyi graphs, are unable to generate synthetic graphs

that accurately represent the topology of real electric power networks { networks

characterized by highly dense local connectivity and clustering and sparse long-haul

links.

This thesis presents a parametrized model that captures the above-mentioned

unique topological properties of electric power networks. Specically, a new Cluster-

and-Connect model is introduced to generate synthetic graphs using these parameters.

Using a uniform set of metrics proposed in the literature, the accuracy of the proposed

model is evaluated by comparing the synthetic models generated for specic real

electric network graphs. In addition to topological properties, the electrical properties

are captured via line impedances that have been shown to be modeled reliably by well-studied heavy tailed distributions. The details of the research, results obtained and

conclusions drawn are presented in this document.

ContributorsHu, Jiale (Author) / Sankar, Lalitha (Thesis advisor) / Vittal, Vijay (Committee member) / Scaglione, Anna (Committee member) / Arizona State University (Publisher)
Created2015
154059-Thumbnail Image.png
Description

Biblical references play an important role in traditional programmatic music. Composers such as Kuhnau, Haydn, Liszt, Messiaen, and Bolcom produced considerable amounts of piano repertoire with biblical allusions: Musical Presentations of Some Biblical Stories in 6 Sonatas (1700) by Kuhnau, The Seven Last Words from Our Saviour on the Cross

Biblical references play an important role in traditional programmatic music. Composers such as Kuhnau, Haydn, Liszt, Messiaen, and Bolcom produced considerable amounts of piano repertoire with biblical allusions: Musical Presentations of Some Biblical Stories in 6 Sonatas (1700) by Kuhnau, The Seven Last Words from Our Saviour on the Cross (1787) by Haydn, The Way of Cross (1878-1879) by Liszt, Twenty Contemplations on the Infant Jesus (1944) by Messiaen, and The Garden of Eden: Four Rags for Piano (1969) by Bolcom. The twentieth century American composers William Bergsma and Louis Weingarden participated in this tradition by producing piano pieces that contain direct biblical quotations. These works, which have received little attention, include two movements from Tangents (1951) by Bergsma and Triptych: Three Pieces for Piano (1969) by Weingarden.

This paper provides a comprehensive analysis of these piano works, considering structural, rhythmic, harmonic, and melodic elements. In particular, the paper examines Bergsma and Weingarden’s work through the technique of word painting in order to illuminate the relationship between the biblical text and music. Key findings include that Bergsma’s Tangents contains dissonant harmonies and irregular rhythms to reflect the agony of people on the biblical Judgement day, while the use of tonality reflects God’s love in other parts. Similarly, Weingarden uses an illustrative style of word painting in Triptych to closely reflect this biblical narrative and scene through the combination of some twelve-tone techniques with chromaticism. These works present a high degree of pianistic and musical elaboration that incorporates twentieth-century compositional techniques, and this paper argues that they merit more attention for recitals by college-level and professional pianists. This paper begins with an introduction which provides the methodological approach used in the paper and a biography of each composer. It then progresses to an analysis of Bergsma’s Tangents, followed by an analysis of Weingarden’s Triptych.

ContributorsHwang, John Yoontae (Author) / Meir, Baruch (Thesis advisor) / Rogers, Rodney (Committee member) / Ryan, Russell (Committee member) / Arizona State University (Publisher)
Created2015
154077-Thumbnail Image.png
Description

ABSTRACT

This dissertation introduces a real-time topology monitoring scheme for power systems intended to provide enhanced situational awareness during major system disturbances. The topology monitoring scheme requires accurate real-time topology information to be effective. This scheme is supported by advances in transmission line outage detection based on data-mining phasor measurement unit

ABSTRACT

This dissertation introduces a real-time topology monitoring scheme for power systems intended to provide enhanced situational awareness during major system disturbances. The topology monitoring scheme requires accurate real-time topology information to be effective. This scheme is supported by advances in transmission line outage detection based on data-mining phasor measurement unit (PMU) measurements.

A network flow analysis scheme is proposed to track changes in user defined minimal cut sets within the system. This work introduces a new algorithm used to update a previous network flow solution after the loss of a single system branch. The proposed new algorithm provides a significantly decreased solution time that is desired in a real- time environment. This method of topology monitoring can provide system operators with visual indications of potential problems in the system caused by changes in topology.

This work also presents a method of determining all singleton cut sets within a given network topology called the one line remaining (OLR) algorithm. During operation, if a singleton cut set exists, then the system cannot withstand the loss of any one line and still remain connected. The OLR algorithm activates after the loss of a transmission line and determines if any singleton cut sets were created. These cut sets are found using properties of power transfer distribution factors and minimal cut sets.

The topology analysis algorithms proposed in this work are supported by line outage detection using PMU measurements aimed at providing accurate real-time topology information. This process uses a decision tree (DT) based data-mining approach to characterize a lost tie line in simulation. The trained DT is then used to analyze PMU measurements to detect line outages. The trained decision tree was applied to real PMU measurements to detect the loss of a 500 kV line and had no misclassifications.

The work presented has the objective of enhancing situational awareness during significant system disturbances in real time. This dissertation presents all parts of the proposed topology monitoring scheme and justifies and validates the methodology using a real system event.

ContributorsWerho, Trevor Nelson (Author) / Vittal, Vijay (Thesis advisor) / Heydt, Gerald (Committee member) / Hedman, Kory (Committee member) / Karady, George G. (Committee member) / Arizona State University (Publisher)
Created2015
152369-Thumbnail Image.png
Description

The Vocal Jazz ensemble, a uniquely American choral form, has grown and flourished in the past half century largely through the efforts of professionals and educators throughout the collegiate music community. This document provides historical data as presented through live and published interviews with key individuals involved in the early

The Vocal Jazz ensemble, a uniquely American choral form, has grown and flourished in the past half century largely through the efforts of professionals and educators throughout the collegiate music community. This document provides historical data as presented through live and published interviews with key individuals involved in the early development of collegiate Vocal Jazz, as well as those who continue this effort currently. It also offers a study of the most influential creative forces that provided the spark for everyone else's fire. A frank discussion on the obstacles encountered and overcome is central to the overall theme of this research into a genre that has moved from a marginalized afterthought to a legitimate, more widely accepted art form. In addition to the perspective provided to future generations of educators in this field, this document also discusses the role of collegiate music academia in preserving and promoting the Vocal Jazz ensemble. The discussion relies on recent data showing the benefits of Vocal Jazz training and the need for authenticity towards its universal integration into college and university vocal performance and music education training.

ContributorsAmerind, Gregory (Author) / Kocour, Michael (Thesis advisor) / Carpenter, Ellon (Committee member) / Britton, David (Committee member) / Ryan, Russell (Committee member) / Arizona State University (Publisher)
Created2013
150431-Thumbnail Image.png
Description

Playing an orchestral reduction is not always the most joyous of times for pianists. As pianists, we have to express a reduced idea of all the instruments and orchestral textures that are in the full score. However, in many cases, there are often omissions, errors or discrepancies in the existing

Playing an orchestral reduction is not always the most joyous of times for pianists. As pianists, we have to express a reduced idea of all the instruments and orchestral textures that are in the full score. However, in many cases, there are often omissions, errors or discrepancies in the existing published reductions. These reductions are made by a variety of people: editors, conductors, pianists, but rarely by the composer, and often do not reflect the composer's true intentions. While many reductions are technically playable, including the reduction of the Sibelius Violin Concerto that will form the basis of this paper, the arrangement of the orchestration can be obscured or inaccurate to the point where the violin soloist may not be receiving the best representation of the actual orchestration. A piano reduction should as closely as possible represent the original intention of the composer, both for the sake of the audience and the performers. The pianist should be able to provide the proper support and orchestration of any reduction for the instrumentalist or vocalist so that the same performance style and technique can be used while performing with either a piano reduction or a full orchestra. This research document contains a detailed examination of the various orchestral reductions of the Sibelius Violin Concerto, culminating in a new version by the author. In this discussion, the author will present a basic understanding of how to orchestrate at the piano through an in-depth explanation of piano skill and technique, practice techniques such as listening to a recorded version of the full orchestration while playing the piano, and ways to study and revise an existing piano reduction. The current published reductions of the Sibelius Violin Concerto contain many errors and discrepancies and will be contrasted with the author's own reduction, available for comparison and study in the appendix. This new revised reduction will clearly show the orchestral instruments represented throughout the score, demonstrate new techniques for various orchestral textures, and will yield a playable product that more closely represents the composer's original intentions.

ContributorsLee, Sehee (Author) / Campbell, Andrew (Thesis advisor) / Rogers, Rodney (Committee member) / Ryan, Russell (Committee member) / Britton, David (Committee member) / Landschoot, Thomas (Committee member) / Arizona State University (Publisher)
Created2011
150668-Thumbnail Image.png
Description

Throughout the history of Western art music, political and religious institutions have exerted powerful influence through their patronage and censorship. This is especially relevant to the organ, an elaborate and expensive instrument which has always depended on institutional support. The fascinating story of Polish organ culture, which has existed since

Throughout the history of Western art music, political and religious institutions have exerted powerful influence through their patronage and censorship. This is especially relevant to the organ, an elaborate and expensive instrument which has always depended on institutional support. The fascinating story of Polish organ culture, which has existed since the Middle Ages, reflects the dramatic changes in Polish politics throughout the centuries. An understanding of this country's history helps to construct a comprehensive view of how politics influenced the developments in organ building and organ playing. This paper describes the dynamics of the Church, government and art institutions in Poland during the years 1945-2012. A brief summary of the history of Polish organ culture sets the stage for the changes occurring after WWII. The constant struggle between the Church and the communist regime affected music making and organ culture in Poland from 1945-1989. The political détente that occurred after 1989 led to a flowering of new instruments, restorations and performance opportunities for organists. By exploring the relationship between Polish organ culture and prevailing agendas in the 20th century, the author demonstrates how a centuries-old tradition adapted to survive political and economic hardships.

ContributorsKubiaczyk-Adler, Ilona (Author) / Marshall, Kimberly (Thesis advisor) / Micklich, Albie (Committee member) / Rockmaker, Jody (Committee member) / Rogers, Rodney (Committee member) / Ryan, Russell (Committee member) / Arizona State University (Publisher)
Created2012