With the desire of high standards of comfort, huge amount of energy is being consumed to maintain the indoor environment. In US building consumes 40% of the total primary energy while residential buildings consume about 21%. A large proportion of this consumption is due to cooling of buildings. Deteriorating environmental

With the desire of high standards of comfort, huge amount of energy is being consumed to maintain the indoor environment. In US building consumes 40% of the total primary energy while residential buildings consume about 21%. A large proportion of this consumption is due to cooling of buildings. Deteriorating environmental conditions due to excessive energy use suggest that we should look at passive designs and renewable energy opportunities to supply the required comfort. Phoenix gets about 300 days of clear sky every year. It also witnesses large temperature variations from night and day. The humidity ratio almost always stays below the 50% mark. With more than six months having outside temperatures more than 75 oF, night sky radiative cooling promise to be an attractive means to cool the buildings during summer. This technique can be useful for small commercial facilities or residential buildings. The roof ponds can be made more effective by covering them with Band Filters. These band filters block the solar heat gain and allow the water to cool down to lower temperatures. It also reduces the convection heat gain. This helps rood ponds maintain lower temperatures and provide more cooling then an exposed pond. 50 μm Polyethylene band filter is used in this study. Using this band filter, roof ponds can be made up to 10% more effective. About 45% of the energy required to cool a typical residential building in summer can be saved.
ContributorsSiddiqui, Mohd. Aqdus (Author) / Bryan, Harvey (Thesis advisor) / Reddy, T Agami (Committee member) / Kroelinger, Michael D. (Committee member) / Arizona State University (Publisher)
Created2013
155959-Thumbnail Image.png
Description
Passive cooling techniques, specifically passive downdraft cooling (PDC), have proven to be a solution that can address issues associated with air conditioning (AC). Globally, over 100 buildings have integrated PDC in its different forms, most of which use direct evaporative cooling. Even though all surveyed buildings were energy efficient and

Passive cooling techniques, specifically passive downdraft cooling (PDC), have proven to be a solution that can address issues associated with air conditioning (AC). Globally, over 100 buildings have integrated PDC in its different forms, most of which use direct evaporative cooling. Even though all surveyed buildings were energy efficient and cost-effective and most surveyed buildings were thermally comfortable, application of PDC remains limited. This study aims to advance performance of the single stage passive downdraft evaporative cooling tower (PDECT), and expand its applicability beyond the hot dry conditions where it is typically used, by designing and testing a multi-stage passive and hybrid downdraft cooling tower (PHDCT). Experimental evaluation on half-scale prototypes of these towers was conducted in Tempe, Arizona, during the hot dry and hot humid days of Summer, 2017. Ambient air dry-bulb temperatures ranged between 73.0°F with 82.9 percent coincident relative humidity, and 123.4°F with 7.8 percent coincident relative humidity. Cooling systems in both towers were operated simultaneously to evaluate performance under identical conditions.



Results indicated that the hybrid tower outperformed the single stage tower under all ambient conditions and that towers site water consumption was at least 2 times lower than source water required by electric powered AC. Under hot dry conditions, the single stage tower produced average temperature drops of 35°F (5°F higher than what was reported in the literature), average air velocities of 200 fpm, and average cooling capacities of 4 tons. Furthermore, the hybrid tower produced average temperature drops of 45°F (50°F in certain operation modes), average air velocities of 160 fpm, and average cooling capacities exceeding 4 tons. Under hot humid conditions, temperature drops from the single stage tower were limited to the ambient air wet-bulb temperatures whereas drops continued beyond the wet-bulb in the hybrid tower, resulting in 60 percent decline in the former’s cooling capacity while maintaining the capacity of the latter. The outcomes from this study will act as an incentive for designers to consider incorporating PDC into their designs as a viable replacement/supplement to AC; thus, reducing the impact of the built environment on the natural environment.
ContributorsAl-Hassawi, Omar Dhia Sadulah (Author) / Bryan, Harvey (Thesis advisor) / Reddy, T Agami (Committee member) / Chalfoun, Nader (Committee member) / Arizona State University (Publisher)
Created2017