Matching Items (3)
151088-Thumbnail Image.png
Description
Approximately 1.7 million people in the United States are living with limb loss and are in need of more sophisticated devices that better mimic human function. In the Human Machine Integration Laboratory, a powered, transtibial prosthetic ankle was designed and build that allows a person to regain ankle function with

Approximately 1.7 million people in the United States are living with limb loss and are in need of more sophisticated devices that better mimic human function. In the Human Machine Integration Laboratory, a powered, transtibial prosthetic ankle was designed and build that allows a person to regain ankle function with improved ankle kinematics and kinetics. The ankle allows a person to walk normally and up and down stairs, but volitional control is still an issue. This research tackled the problem of giving the user more control over the prosthetic ankle using a force/torque circuit. When the user presses against a force/torque sensor located inside the socket the prosthetic foot plantar flexes or moves downward. This will help the user add additional push-off force when walking up slopes or stairs. It also gives the user a sense of control over the device.
ContributorsFronczyk, Adam (Author) / Sugar, Thomas G. (Thesis advisor) / Helms-Tillery, Stephen (Thesis advisor) / Santello, Marco (Committee member) / Arizona State University (Publisher)
Created2012
157461-Thumbnail Image.png
Description
Locomotion is of prime importance in enabling human beings to effectively respond

in space and time to meet different needs. Approximately 2 million Americans live

with an amputation with most of those amputations being of the lower limbs. To

advance current state-of-the-art lower limb prosthetic devices, it is necessary to adapt

performance at a

Locomotion is of prime importance in enabling human beings to effectively respond

in space and time to meet different needs. Approximately 2 million Americans live

with an amputation with most of those amputations being of the lower limbs. To

advance current state-of-the-art lower limb prosthetic devices, it is necessary to adapt

performance at a level of intelligence seen in human walking. As such, this thesis

focuses on the mechanisms involved during human walking, while transitioning from

rigid to compliant surfaces such as from pavement to sand, grass or granular media.

Utilizing a unique tool, the Variable Stiffness Treadmill (VST), as the platform for

human walking, rigid to compliant surface transitions are simulated. The analysis of

muscular activation during the transition from rigid to different compliant surfaces

reveals specific anticipatory muscle activation that precedes stepping on a compliant

surface. There is also an indication of varying responses for different surface stiffness

levels. This response is observed across subjects. Results obtained are novel and

useful in establishing a framework for implementing control algorithm parameters to

improve powered ankle prosthesis. With this, it is possible for the prosthesis to adapt

to a new surface and therefore resulting in a more robust smart powered lower limb

prosthesis.
ContributorsObeng, Ruby Afriyie (Author) / Artemiadis, Panagiotis (Thesis advisor) / Santello, Marco (Thesis advisor) / Lee, Hyunglae (Committee member) / Arizona State University (Publisher)
Created2019
155947-Thumbnail Image.png
Description
In this work, different passive prosthetic ankles are studied. It is observed that complicated designs increase the cost of production, but simple designs have limited functionality. A new design for a passive prosthetic ankle is presented that is simple to manufacture while having superior functionality. This prosthetic ankle design has

In this work, different passive prosthetic ankles are studied. It is observed that complicated designs increase the cost of production, but simple designs have limited functionality. A new design for a passive prosthetic ankle is presented that is simple to manufacture while having superior functionality. This prosthetic ankle design has two springs: one mimicking Achilles tendon and the other mimicking Anterior-Tibialis tendon. The dynamics of the prosthetic ankle is discussed and simulated using Working model 2D. The simulation results are used to optimize the springs stiffness. Two experiments are conducted using the developed ankle to verify the simulation It is found that this novel ankle design is better than Solid Ankle Cushioned Heel (SACH) foot. The experimental data is used to find the tendon and muscle activation forces of the subject wearing the prosthesis using OpenSim. A conclusion is included along with suggested future work.
ContributorsBhat, Sandesh Ganapati (Author) / Redkar, Sangram (Thesis advisor) / Sugar, Thomas (Committee member) / Lee, Hyuglae (Committee member) / Marvi, Hamid (Committee member) / Arizona State University (Publisher)
Created2017