Matching Items (4)
Filtering by

Clear all filters

152340-Thumbnail Image.png
Description
A noninvasive optical method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm that is a peak absorbance of hemoglobin. As the glucose concentration in the blood decreases, its

A noninvasive optical method is developed to monitor rapid changes in blood glucose levels in diabetic patients. The system depends on an optical cell built with a LED that emits light of wavelength 535nm that is a peak absorbance of hemoglobin. As the glucose concentration in the blood decreases, its osmolarity also decreases and the RBCs swell and decrease the path length absorption coefficient. Decreasing absorption coefficient increases the transmission of light through the whole blood. The system was tested with a constructed optical cell that held whole blood in a capillary tube. As expected the light transmitted to the photodiode increases with decreasing glucose concentration. The average response time of the system was between 30-40 seconds. The changes in size of the RBC cells in response to glucose concentration changes were confirmed using a cell counter and also visually under microscope. This method does not allow measuring the glucose concentration with an absolute concentration calibration. It is directed towards development of a device to monitor the changes in glucose concentration as an aid to diabetic management. This method might be improvised for precision and resolution and be developed as a ring or an earring that patients can wear.
ContributorsRajan, Shiny Amala Priya (Author) / Towe, Bruce (Thesis advisor) / Muthuswamy, Jitendran (Committee member) / LaBelle, Jeffrey (Committee member) / Arizona State University (Publisher)
Created2013
150075-Thumbnail Image.png
Description
The long wavelength infrared region (LWIR) and mid wavelength infrared region (MWIR) are of great interest as detection in this region offers a wide range of real time applications. Optoelectronic devices operating in the LWIR and MWIR region offer potential applications such as; optical gas sensing, free-space optical communications, infrared

The long wavelength infrared region (LWIR) and mid wavelength infrared region (MWIR) are of great interest as detection in this region offers a wide range of real time applications. Optoelectronic devices operating in the LWIR and MWIR region offer potential applications such as; optical gas sensing, free-space optical communications, infrared counter-measures, biomedical and thermal imaging etc. HgCdTe is a prominent narrow bandgap material that operates in the LWIR region. The focus of this research work is to simulate and analyze the characteristics of a Hg1-xCdxTe photodetector. To achieve this, the tool `OPTODET' has been developed, where various device parameters can be varied and the resultant output can be analyzed. By the study of output characteristics in response to various changes in device parameters will allow users to understand the considerations that must be made in order to reach the optimum working point of an infrared detector. The tool which has been developed is a 1-D drift diffusion based simulator which solves the 1-D Poisson equation to determine potentials and utilizes the results of the 1-D electron and hole continuity equations to determine current. Parameters such as absorption co-efficient, quantum efficiency, dark current, noise, Transit time and detectivity can be simulated. All major recombination mechanisms such as SRH, Radiative and Auger recombination have been considered. Effects of band to band tunnelling have also been considered to correctly model the dark current characteristics.
ContributorsMuralidharan, Pradyumna (Author) / Vasileska, Dragica (Thesis advisor) / Wijewarnasuriya, Priyalal S. (Committee member) / Zhang, Yong-Hang (Committee member) / Arizona State University (Publisher)
Created2011
150930-Thumbnail Image.png
Description
In this thesis, an integrated waveform-agile multi-modal tracking-beforedetect sensing system is investigated and the performance is evaluated using an experimental platform. The sensing system of adapting asymmetric multi-modal sensing operation platforms using radio frequency (RF) radar and electro-optical (EO) sensors allows for integration of complementary information from different sensors. However,

In this thesis, an integrated waveform-agile multi-modal tracking-beforedetect sensing system is investigated and the performance is evaluated using an experimental platform. The sensing system of adapting asymmetric multi-modal sensing operation platforms using radio frequency (RF) radar and electro-optical (EO) sensors allows for integration of complementary information from different sensors. However, there are many challenges to overcome, including tracking low signal-to-noise ratio (SNR) targets, waveform configurations that can optimize tracking performance and statistically dependent measurements. Address some of these challenges, a particle filter (PF) based recursive waveformagile track-before-detect (TBD) algorithm is developed to avoid information loss caused by conventional detection under low SNR environments. Furthermore, a waveform-agile selection technique is integrated into the PF-TBD to allow for adaptive waveform configurations. The embedded exponential family (EEF) approach is used to approximate distributions of parameters of dependent RF and EO measurements and to further improve target detection rate and tracking performance. The performance of the integrated algorithm is evaluated using real data from three experimental scenarios.
ContributorsLiu, Shubo (Author) / Papandreou-Suppappola, Antonia (Thesis advisor) / Duman, Tolga (Committee member) / Kovvali, Narayan (Committee member) / Arizona State University (Publisher)
Created2012
151156-Thumbnail Image.png
Description
Continuous underwater observation is a challenging engineering task that could be accomplished by development and deployment of a sensor array that can survive harsh underwater conditions. One approach to this challenge is a swarm of micro underwater robots, known as Sensorbots, that are equipped with biogeochemical sensors that can relay

Continuous underwater observation is a challenging engineering task that could be accomplished by development and deployment of a sensor array that can survive harsh underwater conditions. One approach to this challenge is a swarm of micro underwater robots, known as Sensorbots, that are equipped with biogeochemical sensors that can relay information among themselves in real-time. This innovative method for underwater exploration can contribute to a more comprehensive understanding of the ocean by not limiting sampling to a single point and time. In this thesis, Sensorbot Beta, a low-cost fully enclosed Sensorbot prototype for bench-top characterization and short-term field testing, is presented in a modular format that provides flexibility and the potential for rapid design. Sensorbot Beta is designed around a microcontroller driven platform comprised of commercial off-the-shelf components for all hardware to reduce cost and development time. The primary sensor incorporated into Sensorbot Beta is an in situ fluorescent pH sensor. Design considerations have been made for easy adoption of other fluorescent or phosphorescent sensors, such as dissolved oxygen or temperature. Optical components are designed in a format that enables additional sensors. A real-time data acquisition system, utilizing Bluetooth, allows for characterization of the sensor in bench top experiments. The Sensorbot Beta demonstrates rapid calibration and future work will include deployment for large scale experiments in a lake or ocean.
ContributorsJohansen, John (Civil engineer) (Author) / Meldrum, Deirdre R (Thesis advisor) / Chao, Shih-hui (Committee member) / Papandreou-Suppappola, Antonia (Committee member) / Arizona State University (Publisher)
Created2012