Matching Items (6)
Filtering by

Clear all filters

151846-Thumbnail Image.png
Description
Efficiency of components is an ever increasing area of importance to portable applications, where a finite battery means finite operating time. Higher efficiency devices need to be designed that don't compromise on the performance that the consumer has come to expect. Class D amplifiers deliver on the goal of increased

Efficiency of components is an ever increasing area of importance to portable applications, where a finite battery means finite operating time. Higher efficiency devices need to be designed that don't compromise on the performance that the consumer has come to expect. Class D amplifiers deliver on the goal of increased efficiency, but at the cost of distortion. Class AB amplifiers have low efficiency, but high linearity. By modulating the supply voltage of a Class AB amplifier to make a Class H amplifier, the efficiency can increase while still maintaining the Class AB level of linearity. A 92dB Power Supply Rejection Ratio (PSRR) Class AB amplifier and a Class H amplifier were designed in a 0.24um process for portable audio applications. Using a multiphase buck converter increased the efficiency of the Class H amplifier while still maintaining a fast response time to respond to audio frequencies. The Class H amplifier had an efficiency above the Class AB amplifier by 5-7% from 5-30mW of output power without affecting the total harmonic distortion (THD) at the design specifications. The Class H amplifier design met all design specifications and showed performance comparable to the designed Class AB amplifier across 1kHz-20kHz and 0.01mW-30mW. The Class H design was able to output 30mW into 16Ohms without any increase in THD. This design shows that Class H amplifiers merit more research into their potential for increasing efficiency of audio amplifiers and that even simple designs can give significant increases in efficiency without compromising linearity.
ContributorsPeterson, Cory (Author) / Bakkaloglu, Bertan (Thesis advisor) / Barnaby, Hugh (Committee member) / Kiaei, Sayfe (Committee member) / Arizona State University (Publisher)
Created2013
150201-Thumbnail Image.png
Description
It is crucial for counselors to be aware of their own attitudes and beliefs and to prevent them from influencing the counseling process. The prevalence of obesity is growing and biases against obese people are becoming more apparent. Counselors must become aware of the potential weight bias and what factors

It is crucial for counselors to be aware of their own attitudes and beliefs and to prevent them from influencing the counseling process. The prevalence of obesity is growing and biases against obese people are becoming more apparent. Counselors must become aware of the potential weight bias and what factors influence it. The purpose of the current study was to examine whether counselors- in-training hold negative attitudes toward obese clients and whether the career status of the client affects these perceptions. Seventy-six students in graduate level counseling programs at Arizona State University were randomly assigned one of four vignettes describing either an obese bookkeeper, a normal weight bookkeeper, an obese executive, or a normal weight executive. Negative attitudes were measured using two scales; one evaluating perceived personal characteristics of the client and one evaluating the perceived work efficacy. Results indicated that counselors-in-training perceived the client with more negative characteristics when the client was described as obese rather than normal weight, and also when she was described as having a low status job compared to a high status job. The perceived work efficacy of the presented client was not affected by the client’s weight or job status. It is important for students in counseling programs to receive training regarding weight biases and job status biases.
ContributorsPascal, Brittani (Author) / Robinson Kurpius, Sharon E (Thesis advisor) / Homer, Judith (Committee member) / Horan, John J (Committee member) / Arizona State University (Publisher)
Created2011
150020-Thumbnail Image.png
Description
Dietary self-monitoring has been shown to be a predictor of weight loss success and is a prevalent part of behavioral weight control programs. As more weight loss applications have become available on smartphones, this feasibility study investigated whether the use of a smartphone application, or a smartphone memo feature would

Dietary self-monitoring has been shown to be a predictor of weight loss success and is a prevalent part of behavioral weight control programs. As more weight loss applications have become available on smartphones, this feasibility study investigated whether the use of a smartphone application, or a smartphone memo feature would improve dietary self-monitoring over the traditional paper-and-pencil method. The study also looked at whether the difference in methods would affect weight loss. Forty-seven adults (BMI 25 to 40 kg/m2) completed an 8-week study focused on tracking the difference in adherence to a self-monitoring protocol and subsequent weight loss. Participants owning iPhones (n=17) used the 'Lose It' application (AP) for diet and exercise tracking and were compared to smartphone participants who recorded dietary intake using a memo (ME) feature (n=15) on their phone and participants using the traditional paper-and-pencil (PA) method (n=15). There was no significant difference in completion rates between groups with an overall completion rate of 85.5%. The overall mean adherence to self-monitoring for the 8-week period was better in the AP group than the PA group (p = .024). No significant difference was found between the AP group and ME group (p = .148), or the ME group and the PA group (p = .457). Weight loss for the 8 week study was significant for all groups (p = .028). There was no significant difference in weight loss between groups. Number of days recorded regardless of group assignment showed a weak correlation to weight loss success (p = .068). Smartphone owners seeking to lose weight should be encouraged by the potential success associated with dietary tracking using a smartphone app as opposed to the traditional paper-and-pencil method.
ContributorsCunningham, Barbara (Author) / Wharton, Christopher (Christopher Mack), 1977- (Thesis advisor) / Johnston, Carol (Committee member) / Hall, Richard (Committee member) / Arizona State University (Publisher)
Created2012
151246-Thumbnail Image.png
Description
Class D Amplifiers are widely used in portable systems such as mobile phones to achieve high efficiency. The demands of portable electronics for low power consumption to extend battery life and reduce heat dissipation mandate efficient, high-performance audio amplifiers. The high efficiency of Class D amplifiers (CDAs) makes them particularly

Class D Amplifiers are widely used in portable systems such as mobile phones to achieve high efficiency. The demands of portable electronics for low power consumption to extend battery life and reduce heat dissipation mandate efficient, high-performance audio amplifiers. The high efficiency of Class D amplifiers (CDAs) makes them particularly attractive for portable applications. The Digital class D amplifier is an interesting solution to increase the efficiency of embedded systems. However, this solution is not good enough in terms of PWM stage linearity and power supply rejection. An efficient control is needed to correct the error sources in order to get a high fidelity sound quality in the whole audio range of frequencies. A fundamental analysis on various error sources due to non idealities in the power stage have been discussed here with key focus on Power supply perturbations driving the Power stage of a Class D Audio Amplifier. Two types of closed loop Digital Class D architecture for PSRR improvement have been proposed and modeled. Double sided uniform sampling modulation has been used. One of the architecture uses feedback around the power stage and the second architecture uses feedback into digital domain. Simulation & experimental results confirm that the closed loop PSRR & PS-IMD improve by around 30-40 dB and 25 dB respectively.
ContributorsChakraborty, Bijeta (Author) / Bakkaloglu, Bertan (Thesis advisor) / Garrity, Douglas (Committee member) / Ozev, Sule (Committee member) / Arizona State University (Publisher)
Created2012
154094-Thumbnail Image.png
Description
In this thesis, a digital input class D audio amplifier system which has the ability

to reject the power supply noise and nonlinearly of the output stage is presented. The main digital class D feed-forward path is using the fully-digital sigma-delta PWM open loop topology. Feedback loop is used to suppress

In this thesis, a digital input class D audio amplifier system which has the ability

to reject the power supply noise and nonlinearly of the output stage is presented. The main digital class D feed-forward path is using the fully-digital sigma-delta PWM open loop topology. Feedback loop is used to suppress the power supply noise and harmonic distortions. The design is using global foundry 0.18um technology.

Based on simulation, the power supply rejection at 200Hz is about -49dB with

81dB dynamic range and -70dB THD+N. The full scale output power can reach as high as 27mW and still keep minimum -68dB THD+N. The system efficiency at full scale is about 82%.
ContributorsBai, Jing (Author) / Bakkaloglu, Bertan (Thesis advisor) / Arizona State University (Publisher)
Created2015
158590-Thumbnail Image.png
Description
Sedentary behavior and excessive weight gain have been proven to deteriorate many characteristics of muscle. Low muscular power and mass with excess fat mass are risk factors for a multitude of chronic conditions and functional disabilities. Resistance training (RT) has long been accepted as a rehabilitative method of maintaining or

Sedentary behavior and excessive weight gain have been proven to deteriorate many characteristics of muscle. Low muscular power and mass with excess fat mass are risk factors for a multitude of chronic conditions and functional disabilities. Resistance training (RT) has long been accepted as a rehabilitative method of maintaining or enhancing muscular performance and composition. There are various methods of determining lower extremity muscular power; however, isokinetic dynamometry has emerged as one of the most accurate and reliable methods in clinical and research settings. Likewise, various methods exist for determining muscle thickness; however, many of those methods are expensive and can expose individuals to radiation. Ultrasonography has emerged as an accurate and reliable alternative to measuring lower extremity muscle thickness. The objective of this study was to assess the effects of high-load/low-volume (HLLV) and low-load/high-volume (LLHV) RT on isokinetic knee extensor and flexor peak power in sedentary, RT naïve, overweight or obese men and women (Body Mass Index ≥ 25 kg/m2). Twenty-one subjects (n = 21) completed this study and were randomized into one of the following groups: control, a HLLV group that performed three sets of 5 repetitions for all exercises until volitional fatigue, and LLHV which performed three sets of 15 repetitions for all exercises until volitional fatigue. Subjects randomized to the RT groups performed full-body exercises routines on three non-consecutive days per week. Changes in isokinetic knee extensor and flexor peak power, quadriceps ultrasound muscle thickness, and right leg segment of dual-energy X-ray absorptiometry (DEXA) scans were measured before and after the 12-week RT intervention. There were no significant differences found in group, time or, group by time interactions for knee extensor and flexor peak power using isokinetic dynamometry. Other than a group interaction for vastus intermedius muscle thickness (P=0.008), no significant interactions or differences were observed for any of the other variables tested. Based on the results of this study, neither high- nor low-load RT resulted in significant differences between intervention groups in peak power of the knee extensors and flexor, muscle thickness changes of the vastus intermedius, and vastus lateralis and, in the right lower extremity segmented body composition measures using DEXA.
ContributorsSarellis, Sofoklis Demetrios (Author) / Ofori, Edward (Thesis advisor) / Angadi, Siddhartha (Committee member) / Gaesser, Glenn (Committee member) / Arizona State University (Publisher)
Created2020