Matching Items (3)
Filtering by

Clear all filters

150048-Thumbnail Image.png
Description
A wireless hybrid device for detecting volatile organic compounds (VOCs) has been developed. The device combines a highly selective and sensitive tuning-fork based detector with a pre-concentrator and a separation column. The selectivity and sensitivity of the tuning-fork based detector is optimized for discrimination and quantification of benzene, toluene, ethylbenzene,

A wireless hybrid device for detecting volatile organic compounds (VOCs) has been developed. The device combines a highly selective and sensitive tuning-fork based detector with a pre-concentrator and a separation column. The selectivity and sensitivity of the tuning-fork based detector is optimized for discrimination and quantification of benzene, toluene, ethylbenzene, and xylenes (BTEX) via a homemade molecular imprinted polymer, and a specific detection and control circuit. The device is a wireless, portable, battery-powered, and cell-phone operated device. The device has been calibrated and validated in the laboratory and using selected ion flow tube mass spectrometry (SFIT-MS). The capability and robustness are also demonstrated in some field tests. It provides rapid and reliable detection of BTEX in real samples, including challenging high concentrations of interferents, and it is suitable for occupational, environmental health and epidemiological applications.
ContributorsChen, Zheng (Author) / Tao, Nongjian (Thesis advisor) / Chae, Junseok (Committee member) / Forzani, Erica (Committee member) / Arizona State University (Publisher)
Created2011
150905-Thumbnail Image.png
Description
This work demonstrates the integration of a wearable particulate detector and a wireless chemical sensor into a single portable system. The detection philosophy of the chemical sensor is based on highly selective and sensitive microfabricated quartz tuning fork arrays and the particle detector detects the particulate level in real-time using

This work demonstrates the integration of a wearable particulate detector and a wireless chemical sensor into a single portable system. The detection philosophy of the chemical sensor is based on highly selective and sensitive microfabricated quartz tuning fork arrays and the particle detector detects the particulate level in real-time using a nephelometric (light scattering) approach. The device integration is realized by carefully evaluating the needs of flow rate, power and data collection. Validation test has been carried out in both laboratory and in field trials such as parking structures and highway exits with high and low traffic emissions. The integrated single portable detection system is capable of reducing the burden for a child to carry multiple devices, simplifying the task of researchers to synchronize and analyze data from different sensors, and minimizing the overall weight, size, and cost of the sensor. It also has a cell phone for data analysis, storage, and transmission as a user-friendly interface. As the chemical and particulate levels present important exposure risks that are of high interests to epidemiologists, the integrated device will provide an easier, wearable and cost effective way to monitor it.
ContributorsGao, Tianle (Author) / Tao, Nongjian (Thesis advisor) / Chae, Junseok (Committee member) / Tsow, Tsing (Committee member) / Arizona State University (Publisher)
Created2012
149504-Thumbnail Image.png
Description
The thesis focuses on cost-efficient integration of the electro-chemical residue sensor (ECRS), a novel sensor developed for the in situ and real-time measurement of the residual impurities left on the wafer surface and in the fine structures of patterned wafers during typical rinse processes, and wireless transponder circuitry that is

The thesis focuses on cost-efficient integration of the electro-chemical residue sensor (ECRS), a novel sensor developed for the in situ and real-time measurement of the residual impurities left on the wafer surface and in the fine structures of patterned wafers during typical rinse processes, and wireless transponder circuitry that is based on RFID technology. The proposed technology uses only the NMOS FD-SOI transistors with amorphous silicon as active material with silicon nitride as a gate dielectric. The proposed transistor was simulated under the SILVACO ATLAS Simulation Framework. A parametric study was performed to study the impact of different gate lengths (6 μm to 56 μm), electron motilities (0.1 cm2/Vs to 1 cm2/Vs), gate dielectric (SiO2 and SiNx) and active materials (a-Si and poly-Si) specifications. Level-1 models, that are accurate enough to acquire insight into the circuit behavior and perform preliminary design, were successfully constructed by analyzing drain current and gate to node capacitance characteristics against drain to source and gate to source voltages. Using the model corresponding to SiNx as gate dielectric, a-Si:H as active material with electron mobility equal to 0.4 cm2/V-sec, an operational amplifier was designed and was tested in unity gain configuration at modest load-frequency specifications.
ContributorsPandit, Vedhas (Author) / Vermeire, Bert (Thesis advisor) / Barnaby, Hugh (Committee member) / Chae, Junseok (Committee member) / Arizona State University (Publisher)
Created2010