Matching Items (5)
Filtering by

Clear all filters

156405-Thumbnail Image.png
Description
Specific inorganic and organic pollutants in water (As(V), Cr(VI), THMs, and hardness) cause health concerns or aesthetic problems. The goal of this dissertation is to demonstrate novel approaches to improve the performance of point of use and municipal activated carbon processes to provide safe and reliable water to the public

Specific inorganic and organic pollutants in water (As(V), Cr(VI), THMs, and hardness) cause health concerns or aesthetic problems. The goal of this dissertation is to demonstrate novel approaches to improve the performance of point of use and municipal activated carbon processes to provide safe and reliable water to the public at distributed centralized locations.

Template Assisted Crystallization system would adjust saturation index (SI) value of TAC treated water to zero when SI value of influent water was in the range at 0.08~0.3. However, the reduction in SI when SI values were higher (e.g. 0.7~1.3) was similar to the reduction at lower SI values which could be due to limitations in kinetics or mass transfer with the template on TAC media.

Pre-chlorination prior to municipal-scale granular activated carbon (GAC) treatment was evaluated to control THM formation in distribution systems. Pre-chlorination decreased UVA, shift the dissolved organic carbon (DOC) molecular weight distribution and pre-formed trihalomethanes (THM). GAC treatment of pre-chlorinated water achieved lower THM formation in distribution systems.

To add functionality in POU systems to remove As(V) and Cr(VI), activated carbon was nano-tized to fabricate nano-enabled carbon block (CB) by (1) impregnating iron or titanium metal oxides chemically or (2) attaching titanium based P25 through electrostatic attraction force. Nanoparticle loadings of 5 to 10 wt % with respect to activated carbon enables reduction of As(V) or Cr(VI) from levels of common occurrence to below regulatory levels across carbon block designs. Minimal impacts on As(V) and Cr(VI) sorption were observed up to a nanoparticle pre-treatment temperature of 200 C, which is the temperature for CB production. Through controlling pH at 4.5 during mixing of nanoparticles with pH IEP=6 and activated carbon with pH IEP=3, electrostatic attachment of nanoparticles to activated carbon could be achieved prior to fabricating carbon block. A mini carbon block test device was designed, fabricated, and validated to mimic performances of full-scale carbon block using less volumes of test water. As(V) removal tests showed Fe impregnated CB achieved the highest As(V) removal while P25 attached CB had the lowest among three nanoparticles loaded CBs.
ContributorsLee, Heuidae (Author) / Westerhoff, Paul (Thesis advisor) / Fox, Peter (Committee member) / Hristovski, Kiril (Committee member) / Arizona State University (Publisher)
Created2018
155778-Thumbnail Image.png
Description
Contamination of drinking water supplies from oxo-anion pollutants necessitates treatment prior to potable use. This dissertation aims to inform and improve light delivery (emission spectra, radiant intensity, reactor configuration) in order to enhance the photocatalytic reduction of hexavalent chromium (Cr(VI)) and nitrate, two common oxo-anions in drinking water, and photocatalytic

Contamination of drinking water supplies from oxo-anion pollutants necessitates treatment prior to potable use. This dissertation aims to inform and improve light delivery (emission spectra, radiant intensity, reactor configuration) in order to enhance the photocatalytic reduction of hexavalent chromium (Cr(VI)) and nitrate, two common oxo-anions in drinking water, and photocatalytic oxidation of two model organic pollutants (methylene blue, (MB) and para-chlorobenzoic acid (pCBA)). By varying the photon fluence dose, two metrics (contaminant quantum yield (Φ), and electrical energy per order (EEO)) were used to assess photocatalytic reactor performance. A detailed literature review and experimental results demonstrated how different irradiance sources with variable intensity and emission spectra synergistically enhanced contaminant removal by a coupled photolytic/photocatalytic reaction mechanism. Cr(VI) was photocatalytically reduced on TiO2 and formed Cr(OH)3(s) in a large-scale slurry reactor, but Cr(III) was then photolyzed and reformed Cr(VI). UV light also led to photo-aggregation of TiO2 which improved its recovery by the ceramic membrane within the reactor. For nitrate reduction, light source emission spectra and fluence dose delineate the preferred pathways as intermediates were reduced via wavelength-dependent mechanisms. HONO was identified as a key nitrate reduction intermediate, which was reduced photocatalytically (UV wavelengths) and/or readily photolyzed at 365nm, to yield nitrogen gases. Photocatalytic nitrate reduction efficiency was higher for discrete wavelength irradiation than polychromatic irradiation. Light delivery through aqueous media to the catalyst surface limits efficiency of slurry-based photocatalysts because absorption and scattering of light in nanomaterial slurries decreases effective photon transmittance and minimizes photolytic reactions. The use of optical fibers coupled to light emitting diodes (OF-LED) with immobilized catalyst demonstrated higher performance compared to slurry systems. OF-LED increased Φ for MB degradation by increasing direct photon delivery to the photocatalyst. Design of OF-LED reactors using bundled optical fibers demonstrated photocatalytic pCBA removal with high Φ and reduced EEO due to increased surface area and catalytic sites compared to single OF/LED couples. This work advances light delivery as well as the suspension and attachment of nanoparticles in photocatalytic water treatment for selective transformation of oxo-anions and organic compounds to innocuous species.
ContributorsTugaoen, Heather O'Neal (Author) / Westerhoff, Paul (Thesis advisor) / Hristovski, Kiril (Thesis advisor) / Chan, Candace (Committee member) / Arizona State University (Publisher)
Created2017
155866-Thumbnail Image.png
Description
Activated Carbon has been used for decades to remove organics from water at large scale in municipal water treatment as well as at small scale in Point of Use (POU) and Point of Entry (POE) water treatment. This study focused on Granular Activated Carbon (GAC) and also activated Carbon Block

Activated Carbon has been used for decades to remove organics from water at large scale in municipal water treatment as well as at small scale in Point of Use (POU) and Point of Entry (POE) water treatment. This study focused on Granular Activated Carbon (GAC) and also activated Carbon Block (CB) were studied.

This thesis has three related elements for organics control in drinking water. First, coagulation chemistry for Alum and Aluminum Chlorohydrate (ACH) was optimized for significant organics removal to address membrane fouling issue at a local municipal water treatment plant in Arizona. Second, Rapid Small Scale Column Tests were conducted for removal of Perfluorinated compounds (PFC), PFC were present in groundwater at a local site in Arizona at trace levels with combined concentration of Perfluorooctaneoic Acid (PFOA) and Perfloorooctanesulfonic Acid (PFOS) up to 245 ng/L. Groundwater from the concerned site is used as drinking water source by a private utility. PFC Removal was evaluated for different GAC, influent concentrations and particle sizes. Third, a new testing protocol (Mini Carbon Block (MCB)) for bench scale study of POU water treatment device, specifically carbon block filter was developed and evaluated. The new bench scale decreased the hydraulic requirements by 60 times approximately, which increases the feasibility to test POU at a lab scale. It was evaluated for a common POU organic contaminant: Chloroform, and other model contaminants.

10 mg/L of ACH and 30 mg/L of Alum with pH adjustment were determined as optimal coagulant doses. Bituminous coal based GAC was almost three times better than coconut shell based GAC for removing PFC. Multiple tests with MCB suggested no short circuiting and consistent performance for methylene blue though chloroform removal tests underestimated full scale carbon block performance but all these tests creates a good theoretical and practical fundament for this new approach and provides directions for future researchers.
ContributorsAshani, Harsh Satishbhai (Author) / Westerhoff, Paul (Thesis advisor) / Hristovski, Kiril (Committee member) / Conroy-Ben, Otakuye (Committee member) / Arizona State University (Publisher)
Created2017
152356-Thumbnail Image.png
Description
Hexavalant chromium (Cr(VI)) poses an emerging concern in drinking water treatment with stricter regulations on the horizon. Photocatalytic reduction of Cr(VI) was investigated as an engineering scale option to remove hexavalent chromium from drinking or industrial waters via a UV/titanium dioxide (TiO2) process. Using an integrated UV lamp/ceramic membrane system

Hexavalant chromium (Cr(VI)) poses an emerging concern in drinking water treatment with stricter regulations on the horizon. Photocatalytic reduction of Cr(VI) was investigated as an engineering scale option to remove hexavalent chromium from drinking or industrial waters via a UV/titanium dioxide (TiO2) process. Using an integrated UV lamp/ceramic membrane system to recirculate TiO2, both hexavalent and total chromium levels were reduced through photocatalytic processes without additional chemicals. Cr(VI) removal increased as a function of higher energy input and TiO2 dosage, achieving above 90% removal for a 1g/L dose of TiO2. Surface analysis of effluent TiO2 confirmed the presence of chromium species.
ContributorsStancl, Heather O'Neal (Author) / Westerhoff, Paul K (Thesis advisor) / Chan, Candace (Committee member) / Hristovski, Kiril (Committee member) / Arizona State University (Publisher)
Created2013
154278-Thumbnail Image.png
Description
Ion exchange sorbents embedded with metal oxide nanoparticles can have high affinity and high capacity to simultaneously remove multiple oxygenated anion contaminants from drinking water. This research pursued answering the question, “Can synthesis methods of nano-composite sorbents be improved to increase sustainability and feasibility to remove hexavalent chromium and arsenic

Ion exchange sorbents embedded with metal oxide nanoparticles can have high affinity and high capacity to simultaneously remove multiple oxygenated anion contaminants from drinking water. This research pursued answering the question, “Can synthesis methods of nano-composite sorbents be improved to increase sustainability and feasibility to remove hexavalent chromium and arsenic simultaneously from groundwater compared to existing sorbents?” Preliminary nano-composite sorbents outperformed existing sorbents in equilibrium tests, but struggled in packed bed applications and at low influent concentrations. The synthesis process was then tailored for weak base anion exchange (WBAX) while comparing titanium dioxide against iron hydroxide nanoparticles (Ti-WBAX and Fe-WBAX, respectively). Increasing metal precursor concentration increased the metal content of the created sorbents, but pollutant removal performance and usable surface area declined due to pore blockage and nanoparticle agglomeration. An acid-post rinse was required for Fe-WBAX to restore chromium removal capacity. Anticipatory life cycle assessment identified critical design constraints to improve environmental and human health performance like minimizing oven heating time, improving pollutant removal capacity, and efficiently reusing metal precursor solution. The life cycle environmental impact of Ti-WBAX was lower than Fe-WBAX as well as a mixed bed of WBAX and granular ferric hydroxide for all studied categories. A separate life cycle assessment found the total number of cancer and non-cancer cases prevented by drinking safer water outweighed those created by manufacture and use of water treatment materials and energy. However, treatment relocated who bore the health risk, concentrated it in a sub-population, and changed the primary manifestation from cancer to non-cancer disease. This tradeoff was partially mitigated by avoiding use of pH control chemicals. When properly synthesized, Fe-WBAX and Ti-WBAX sorbents maintained chromium removal capacity while significantly increasing arsenic removal capacity compared to the parent resin. The hybrid sorbent performance was demonstrated in packed beds using a challenging water matrix and low pollutant influent conditions. Breakthrough curves hint that the hexavalent chromium is removed by anion exchange and the arsenic is removed by metal oxide sorption. Overall, the hybrid nano-sorbent synthesis methods increased sustainability, improved sorbent characteristics, and increased simultaneous removal of chromium and arsenic for drinking water.
ContributorsGifford, James McKay (Author) / Westerhoff, Paul (Thesis advisor) / Hristovski, Kiril (Thesis advisor) / Chester, Mikhail (Committee member) / Arizona State University (Publisher)
Created2016