Matching Items (4)
Filtering by

Clear all filters

156062-Thumbnail Image.png
Description
Drinking water filtration using reverse osmosis (RO) membranes effectively removes salts and most other inorganic, organic, and microbial pollutants. RO technologies are utilized at both the municipal and residential scale. The formation of biofilms on RO membranes reduces water flux and increases energy consumption. The research conducted for this thesis

Drinking water filtration using reverse osmosis (RO) membranes effectively removes salts and most other inorganic, organic, and microbial pollutants. RO technologies are utilized at both the municipal and residential scale. The formation of biofilms on RO membranes reduces water flux and increases energy consumption. The research conducted for this thesis involves In-Situ coating of silver, a known biocide, on the surface of RO membranes. This research was adapted from a protocol developed for coating flat sheet membranes with silver nanoparticles, and scaled up into spiral-wound membranes that are commonly used at the residential scale in point-of-use (POU) filtration systems. Performance analyses of the silver-coated spiral-wound were conducted in a mobile drinking water treatment system fitted with two POU units for comparison. Five month-long analyses were performed, including a deployment of the mobile system. In addition to flux, salt rejection, and other water quality analyses, additional membrane characterization tests were conducted on pristine and silver-coated membranes.

For flat sheet membranes coated with silver, the surface charge remained negative and contact angle remained below 90. Scaling up to spiral-wound RO membrane configuration was successful, with an average silver-loading of 1.93 g-Ag/cm2. Results showed the flux of water through the membrane ranged from 8 to 13 liters/m2*hr. (LMH) operating at 25% recovery during long-term of operation. The flux was initially decreased due to the silver coating, but no statistically significant differences were observed after 14 days of operation (P < 0.05). The salt rejection was also not effected due to the silver coating (P < 0.05). While 98% of silver was released during long-term studies, the silver release from the spiral-wound membrane was consistently below the secondary MCL of 100 ppb established by the EPA, and was consistently below 5 ppb after two hours of operation. Microbial assays in the form of heterotrophic plate counts suggested there was no statistically significant difference in the prevention of biofouling formation due to the silver coating (P < 0.05). In addition to performance tests and membrane characterizations, a remote data acquisition system was configured to remotely monitor performance and water quality parameters in the mobile system.
ContributorsZimmerman, Sean (Author) / Westerhoff, Paul K (Thesis advisor) / Sinha, Shahnawaz (Committee member) / Perreault, Francois (Committee member) / Arizona State University (Publisher)
Created2017
156029-Thumbnail Image.png
Description
With the application of reverse osmosis (RO) membranes in the wastewater treatment and seawater desalination, the limitation of flux and fouling problems of RO have gained more attention from researchers. Because of the tunable structure and physicochemical properties of nanomaterials, it is a suitable material that can be used to

With the application of reverse osmosis (RO) membranes in the wastewater treatment and seawater desalination, the limitation of flux and fouling problems of RO have gained more attention from researchers. Because of the tunable structure and physicochemical properties of nanomaterials, it is a suitable material that can be used to incorporate with RO to change the membrane performances. Silver is biocidal, which has been used in a variety of consumer products. Recent studies showed that fabricating silver nanoparticles (AgNPs) on membrane surfaces can mitigate the biofouling problem on the membrane. Studies have shown that Ag released from the membrane in the form of either Ag ions or AgNP will accelerate the antimicrobial activity of the membrane. However, the silver release from the membrane will lower the silver loading on the membrane, which will eventually shorten the antimicrobial activity lifetime of the membrane. Therefore, the silver leaching amount is a crucial parameter that needs to be determined for every type of Ag composite membrane.

This study is attempting to compare four different silver leaching test methods, to study the silver leaching potential of the silver impregnated membranes, conducting the advantages and disadvantages of the leaching methods. An In-situ reduction Ag loaded RO membrane was examined in this study. A custom waterjet test was established to create a high-velocity water flow to test the silver leaching from the nanocomposite membrane in a relative extreme environment. The batch leaching test was examined as the most common leaching test method for the silver composite membrane. The cross-flow filtration and dead-end test were also examined to compare the silver leaching amounts.

The silver coated membrane used in this experiment has an initial silver loading of 2.0± 0.51 ug/cm2. The mass balance was conducted for all of the leaching tests. For the batch test, water jet test, and dead-end filtration, the mass balances are all within 100±25%, which is acceptable in this experiment because of the variance of the initial silver loading on the membranes. A bad silver mass balance was observed at cross-flow filtration. Both of AgNP and Ag ions leached in the solution was examined in this experiment. The concentration of total silver leaching into solutions from the four leaching tests are all below the Secondary Drinking Water Standard for silver which is 100 ppb. The cross-flow test is the most aggressive leaching method, which has more than 80% of silver leached from the membrane after 50 hours of the test. The water jet (54 ± 6.9% of silver remaining) can cause higher silver leaching than batch test (85 ± 1.2% of silver remaining) in one-hour, and it can also cause both AgNP and Ag ions leaching from the membrane, which is closer to the leaching condition in the cross-flow test.
ContributorsHan, Bingru (Author) / Westerhoff, Paul (Thesis advisor) / Perreault, Francois (Committee member) / Sinha, Shahnawaz (Committee member) / Arizona State University (Publisher)
Created2017
147954-Thumbnail Image.png
Description

This study investigated the difference in biofilm growth between pristine polypropylene microplastics and aged polypropylene microplastics. The microplastics were added to Tempe Town Lake water for 4 weeks. Each week the microplastic biofilms were quantified. Comparing the total biofilm counts, the results showed that the aged microplastic biofilms were larger

This study investigated the difference in biofilm growth between pristine polypropylene microplastics and aged polypropylene microplastics. The microplastics were added to Tempe Town Lake water for 4 weeks. Each week the microplastic biofilms were quantified. Comparing the total biofilm counts, the results showed that the aged microplastic biofilms were larger than the pristine each week. By week 3 the aged microplastic counts had almost doubled in size increasing from 324 to 626 Colony Forming Units per gram in just one week. There was a significant difference in the diversity found from week 1 to week 4. About 40% of the diversity for the pristine microplastic biofilm was seen as light-yellow dots and about 60% of these dots were seen on the aged microplastic biofilms in both weeks. As the microplastics were submerged in the lake water, new phenotypes emerged varying from week 1 to week 4 and from pristine to aged microplastic biofilms. Generally, it was found that as the microplastics stay in the environment there is more biofilm on the particles. The aged microplastics have a larger amount of biofouling, and the pristine microplastic biofilms were found to have more diversity of phenotypes.

Created2021-05
157964-Thumbnail Image.png
Description
This dissertation investigates the mechanisms that lead to fouling, as well as how an understanding of how these mechanisms can be leveraged to mitigate fouling.

To limit fouling on feed spacers, various coatings were applied. The results showed silver-coated biocidal spacers outperformed other spacers by all measures. The control polypropylene

This dissertation investigates the mechanisms that lead to fouling, as well as how an understanding of how these mechanisms can be leveraged to mitigate fouling.

To limit fouling on feed spacers, various coatings were applied. The results showed silver-coated biocidal spacers outperformed other spacers by all measures. The control polypropylene spacers performed in-line with, or better than, the other coatings. Polypropylene’s relative anti-adhesiveness is due to its surface free energy (SFE; 30.0 +/- 2.8 mN/m), which, according to previously generated models, is near the ideal SFE for resisting adhesion of bacteria and organics (~25 mN/m).

Previous research has indicated that electrochemical surfaces can be used to remove biofilms. To better elucidate the conditions and kinetics of biofilm removal, optical coherence tomography microscopy was used to visualize the biofouling and subsequent cleaning of the surface. The 50.0 mA cm-2 and 87.5 mA cm-2 current densities proved most effective in removing the biofilm. The 50.0 mA cm-2 condition offers the best balance between performance and energy use for anodic operation.

To test the potential to incorporate electrochemical coatings into infrastructure, membranes were coated with carbon nanotubes (CNTs), rendering the membranes electrochemically active. These membranes were biofouled and subsequently cleaned via electrochemical reactions. P. aeruginosa was given 72h to develop a biofilm on the CNT-coated membranes in a synthetic medium simulating desalination brines. Cathodic reactions, which generate H2 gas, produce vigorous bubbling at a current density of 12.5 mA cm-2 and higher, leading to a rapid and complete displacement of the biofilm from the CNT-functionalized membrane surface. In comparison, anodic reactions were unable to disperse the biofilms from the surface at similar current densities.

The scaling behavior of a nanophotonics-enabled solar membrane distillation (NESMD) system was investigated. The results showed the NESMD system to be resistant to scaling. The system operated without any decline in flux up to concentrations 6x higher than the initial salt concentration (8,439 mg/L), whereas in traditional membrane distillation (MD), flux essentially stopped at a salt concentration factor of 2x. Microscope and analytical analyses showed more fouling on the membranes from the MD system.
ContributorsRice, Douglas, Ph.D (Author) / Perreault, Francois (Thesis advisor) / Abbaszadegan, Morteza (Committee member) / Fox, Peter (Committee member) / Lind-Thomas, Mary Laura (Committee member) / Arizona State University (Publisher)
Created2019