Exposure of blood plasma/serum (P/S) to thawed conditions, greater than -30°C, can produce biomolecular changes that misleadingly impact measurements of clinical markers within archived samples. Reported here is a low sample-volume, dilute-and-shoot, intact protein mass spectrometric assay of albumin proteoforms called “ΔS-Cys-Albumin” that quantifies cumulative exposure of archived P/S samples

Exposure of blood plasma/serum (P/S) to thawed conditions, greater than -30°C, can produce biomolecular changes that misleadingly impact measurements of clinical markers within archived samples. Reported here is a low sample-volume, dilute-and-shoot, intact protein mass spectrometric assay of albumin proteoforms called “ΔS-Cys-Albumin” that quantifies cumulative exposure of archived P/S samples to thawed conditions. The assay uses the fact that S-cysteinylation (oxidation) of albumin in P/S increases to a maximum value when exposed to temperatures greater than -30°C. The multi-reaction rate law that governs this albumin S-cysteinylation formation in P/S was determined and was shown to predict the rate of formation of S-cysteinylated albumin in P/S samples—a step that enables back-calculation of the time at which unknown P/S specimens have been exposed to room temperature. To emphasize the capability of this assay, a blind challenge demonstrated the ability of ΔS-Cys-Albumin to detect exposure of individual and grouped P/S samples to unfavorable storage conditions. The assay was also capable of detecting an anomaly in a case study of nominally pristine serum samples collected under NIH-sponsorship, demonstrating that empirical evidence is required to guarantee accurate knowledge of archived P/S biospecimen storage history.

The ex vivo glycation of human serum albumin was also investigated showing that P/S samples stored above their freezing point leads to significant increases in glycated albumin. These increases were found to occur within hours at room temperature, and within days at -20 °C. These increases continued over a period of 1-2 weeks at room temperature and over 200 days at -20 °C, ultimately resulting in a doubling of glycated albumin in both healthy and diabetic patients. It was also shown that samples stored at lower surface area-to-volume ratios or incubated under a nitrogen atmosphere experienced less rapid glucose adduction of albumin—suggesting a role for oxidative glycation in the ex vivo glycation of albumin.
ContributorsJeffs, Joshua W (Author) / Borges, Chad R (Thesis advisor) / Van Horn, Wade (Committee member) / Williams, Peter (Committee member) / Arizona State University (Publisher)
Created2018
136922-Thumbnail Image.png
Description
A high voltage plasma arc can be created and sustained in air by subjecting the gases to an electric field with high voltage potential, causing ionization. The internal energy of the ionized gases can be transferred to corresponding pressure waves when the matter involved switches between the gaseous and plasma

A high voltage plasma arc can be created and sustained in air by subjecting the gases to an electric field with high voltage potential, causing ionization. The internal energy of the ionized gases can be transferred to corresponding pressure waves when the matter involved switches between the gaseous and plasma states. By pulse-width modulating a transformer driving signal, the transfer of internal electrical energy to resonating pressure waves may be controlled. Audio wave input to the driver signal can then be modulated into the carrier wave and be used to determine the width of each pulse in the plasma, thus reconstructing the audio signal as pressure, or sound waves, as the plasma arc switches on and off. The result will be the audio waveform resonating out of the plasma arc as audible sound, and thus creating a plasma loudspeaker. Theory of operation was tested through construction of a plasma arc speaker, and resultant audio playback was analyzed. This analysis confirmed accurate reproduction of audio signal in audible sound.