Matching Items (2)
Filtering by
- All Subjects: Infrared
- Creators: Clarke, Amanda B
Description
Many planetary science missions study thermophysical properties of surfaces using infrared spectrometers and infrared cameras. Thermal inertia is a frequently derived thermophysical property that quantifies the ability for heat to exchange through planetary surfaces.
To conceptualize thermal inertia, the diffusion equation analogies are extended using a general effusivity term: the square root of a product of conductivity and capacity terms. A hypothetical thermal inductance was investigated for diurnal planetary heating. The hyperbolic heat diffusion equation was solved to derive an augmented thermal inertia. The hypothetical thermal inductance was modeled with negligible effect on Mars.
Extending spectral performance of infrared cameras was desired for colder bodies in the outer solar system where peak infrared emission is at longer wavelengths. The far-infrared response of an infrared microbolometer array with a retrofitted diamond window was determined using an OSIRIS-REx—OTES interferometer. An instrument response function of the diamond interferometer-microbolometer system shows extended peak performance from 15 µm out to 20 µm and 40% performance to at least 30 µm. The results are folded into E-THEMIS for the NASA flagship mission: Europa Clipper.
Infrared camera systems are desired for the expanding smallsat community that can inherit risk and relax performance requirements. The Thermal-camera for Exploration, Science, and Imaging Spacecraft (THESIS) was developed for the Prox-1 microsat mission. THESIS, incorporating 2001 Mars Odyssey—THEMIS experience, consists of an infrared camera, a visible camera, and an instrument computer. THESIS was planned to provide images for demonstrating autonomous proximity operations between two spacecraft, verifying deployment of the Planetary Society’s LightSail-B, and conducting remote sensing of Earth. Prox-1—THESIS was selected as the finalist for the competed University Nanosatellite Program-7 and was awarded a launch on the maiden commercial SpaceX Falcon Heavy. THESIS captures 8-12 µm IR images with 100 mm optics and RGB color images with 25 mm optics. The instrument computer was capable of instrument commanding, automatic data processing, image storage, and telemetry recording. The completed THESIS has a mass of 2.04 kg, a combined volume of 3U, and uses 7W of power. THESIS was designed, fabricated, integrated, and tested in ASU’s 100K clean lab.
To conceptualize thermal inertia, the diffusion equation analogies are extended using a general effusivity term: the square root of a product of conductivity and capacity terms. A hypothetical thermal inductance was investigated for diurnal planetary heating. The hyperbolic heat diffusion equation was solved to derive an augmented thermal inertia. The hypothetical thermal inductance was modeled with negligible effect on Mars.
Extending spectral performance of infrared cameras was desired for colder bodies in the outer solar system where peak infrared emission is at longer wavelengths. The far-infrared response of an infrared microbolometer array with a retrofitted diamond window was determined using an OSIRIS-REx—OTES interferometer. An instrument response function of the diamond interferometer-microbolometer system shows extended peak performance from 15 µm out to 20 µm and 40% performance to at least 30 µm. The results are folded into E-THEMIS for the NASA flagship mission: Europa Clipper.
Infrared camera systems are desired for the expanding smallsat community that can inherit risk and relax performance requirements. The Thermal-camera for Exploration, Science, and Imaging Spacecraft (THESIS) was developed for the Prox-1 microsat mission. THESIS, incorporating 2001 Mars Odyssey—THEMIS experience, consists of an infrared camera, a visible camera, and an instrument computer. THESIS was planned to provide images for demonstrating autonomous proximity operations between two spacecraft, verifying deployment of the Planetary Society’s LightSail-B, and conducting remote sensing of Earth. Prox-1—THESIS was selected as the finalist for the competed University Nanosatellite Program-7 and was awarded a launch on the maiden commercial SpaceX Falcon Heavy. THESIS captures 8-12 µm IR images with 100 mm optics and RGB color images with 25 mm optics. The instrument computer was capable of instrument commanding, automatic data processing, image storage, and telemetry recording. The completed THESIS has a mass of 2.04 kg, a combined volume of 3U, and uses 7W of power. THESIS was designed, fabricated, integrated, and tested in ASU’s 100K clean lab.
ContributorsVeto, Michael (Author) / Christensen, Philip C (Thesis advisor) / Bell III, Jim (Committee member) / Clarke, Amanda B (Committee member) / Asphaug, Erik (Committee member) / Sariapli, Srikanth (Committee member) / Ruff, Steven (Committee member) / Arizona State University (Publisher)
Created2018
Description
Readout Integrated Circuits(ROICs) are important components of infrared(IR) imag
ing systems. Performance of ROICs affect the quality of images obtained from IR
imaging systems. Contemporary infrared imaging applications demand ROICs that
can support large dynamic range, high frame rate, high output data rate, at low
cost, size and power. Some of these applications are military surveillance, remote
sensing in space and earth science missions and medical diagnosis. This work focuses
on developing a ROIC unit cell prototype for National Aeronautics and Space Ad
ministration(NASA), Jet Propulsion Laboratory’s(JPL’s) space applications. These
space applications also demand high sensitivity, longer integration times(large well
capacity), wide operating temperature range, wide input current range and immunity
to radiation events such as Single Event Latchup(SEL).
This work proposes a digital ROIC(DROIC) unit cell prototype of 30ux30u size,
to be used mainly with NASA JPL’s High Operating Temperature Barrier Infrared
Detectors(HOT BIRDs). Current state of the art DROICs achieve a dynamic range
of 16 bits using advanced 65-90nm CMOS processes which adds a lot of cost overhead.
The DROIC pixel proposed in this work uses a low cost 180nm CMOS process and
supports a dynamic range of 20 bits operating at a low frame rate of 100 frames per
second(fps), and a dynamic range of 12 bits operating at a high frame rate of 5kfps.
The total electron well capacity of this DROIC pixel is 1.27 billion electrons, enabling
integration times as long as 10ms, to achieve better dynamic range. The DROIC unit
cell uses an in-pixel 12-bit coarse ADC and an external 8-bit DAC based fine ADC.
The proposed DROIC uses layout techniques that make it immune to radiation up to
300krad(Si) of total ionizing dose(TID) and single event latch-up(SEL). It also has a
wide input current range from 10pA to 1uA and supports detectors operating from
Short-wave infrared (SWIR) to longwave infrared (LWIR) regions.
ing systems. Performance of ROICs affect the quality of images obtained from IR
imaging systems. Contemporary infrared imaging applications demand ROICs that
can support large dynamic range, high frame rate, high output data rate, at low
cost, size and power. Some of these applications are military surveillance, remote
sensing in space and earth science missions and medical diagnosis. This work focuses
on developing a ROIC unit cell prototype for National Aeronautics and Space Ad
ministration(NASA), Jet Propulsion Laboratory’s(JPL’s) space applications. These
space applications also demand high sensitivity, longer integration times(large well
capacity), wide operating temperature range, wide input current range and immunity
to radiation events such as Single Event Latchup(SEL).
This work proposes a digital ROIC(DROIC) unit cell prototype of 30ux30u size,
to be used mainly with NASA JPL’s High Operating Temperature Barrier Infrared
Detectors(HOT BIRDs). Current state of the art DROICs achieve a dynamic range
of 16 bits using advanced 65-90nm CMOS processes which adds a lot of cost overhead.
The DROIC pixel proposed in this work uses a low cost 180nm CMOS process and
supports a dynamic range of 20 bits operating at a low frame rate of 100 frames per
second(fps), and a dynamic range of 12 bits operating at a high frame rate of 5kfps.
The total electron well capacity of this DROIC pixel is 1.27 billion electrons, enabling
integration times as long as 10ms, to achieve better dynamic range. The DROIC unit
cell uses an in-pixel 12-bit coarse ADC and an external 8-bit DAC based fine ADC.
The proposed DROIC uses layout techniques that make it immune to radiation up to
300krad(Si) of total ionizing dose(TID) and single event latch-up(SEL). It also has a
wide input current range from 10pA to 1uA and supports detectors operating from
Short-wave infrared (SWIR) to longwave infrared (LWIR) regions.
ContributorsPraveen, Subramanya Chilukuri (Author) / Bakkaloglu, Bertan (Thesis advisor) / Kitchen, Jennifer (Committee member) / Long, Yu (Committee member) / Arizona State University (Publisher)
Created2019