Matching Items (4)
Filtering by

Clear all filters

152160-Thumbnail Image.png
Description
A cerebral aneurysm is an abnormal ballooning of the blood vessel wall in the brain that occurs in approximately 6% of the general population. When a cerebral aneurysm ruptures, the subsequent damage is lethal damage in nearly 50% of cases. Over the past decade, endovascular treatment has emerged as an

A cerebral aneurysm is an abnormal ballooning of the blood vessel wall in the brain that occurs in approximately 6% of the general population. When a cerebral aneurysm ruptures, the subsequent damage is lethal damage in nearly 50% of cases. Over the past decade, endovascular treatment has emerged as an effective treatment option for cerebral aneurysms that is far less invasive than conventional surgical options. Nonetheless, the rate of successful treatment is as low as 50% for certain types of aneurysms. Treatment success has been correlated with favorable post-treatment hemodynamics. However, current understanding of the effects of endovascular treatment parameters on post-treatment hemodynamics is limited. This limitation is due in part to current challenges in in vivo flow measurement techniques. Improved understanding of post-treatment hemodynamics can lead to more effective treatments. However, the effects of treatment on hemodynamics may be patient-specific and thus, accurate tools that can predict hemodynamics on a case by case basis are also required for improving outcomes.Accordingly, the main objectives of this work were 1) to develop computational tools for predicting post-treatment hemodynamics and 2) to build a foundation of understanding on the effects of controllable treatment parameters on cerebral aneurysm hemodynamics. Experimental flow measurement techniques, using particle image velocimetry, were first developed for acquiring flow data in cerebral aneurysm models treated with an endovascular device. The experimental data were then used to guide the development of novel computational tools, which consider the physical properties, design specifications, and deployment mechanics of endovascular devices to simulate post-treatment hemodynamics. The effects of different endovascular treatment parameters on cerebral aneurysm hemodynamics were then characterized under controlled conditions. Lastly, application of the computational tools for interventional planning was demonstrated through the evaluation of two patient cases.
ContributorsBabiker, M. Haithem (Author) / Frakes, David H (Thesis advisor) / Adrian, Ronald (Committee member) / Caplan, Michael (Committee member) / Chong, Brian (Committee member) / Vernon, Brent (Committee member) / Arizona State University (Publisher)
Created2013
137098-Thumbnail Image.png
Description
This paper summarizes the [1] ideas behind, [2] needs, [3] development, and [4] testing of 3D-printed sensor-stents known as Stentzors. This sensor was successfully developed entirely from scratch, tested, and was found to have an output of 3.2*10-6 volts per RMS pressure in pascals. This paper also recommends further work

This paper summarizes the [1] ideas behind, [2] needs, [3] development, and [4] testing of 3D-printed sensor-stents known as Stentzors. This sensor was successfully developed entirely from scratch, tested, and was found to have an output of 3.2*10-6 volts per RMS pressure in pascals. This paper also recommends further work to render the Stentzor deployable in live subjects, including [1] further design optimization, [2] electrical isolation, [3] wireless data transmission, and [4] testing for aneurysm prevention.
ContributorsMeidinger, Aaron Michael (Author) / LaBelle, Jeffrey (Thesis director) / Frakes, David (Committee member) / Barrett, The Honors College (Contributor) / Mechanical and Aerospace Engineering Program (Contributor)
Created2014-05
151444-Thumbnail Image.png
Description
Assessments for the threats posed by volcanic eruptions rely in large part on the accurate prediction of volcanic plume motion over time. That predictive capacity is currently hindered by a limited understanding of volcanic plume dynamics. While eruption rate is considered a dominant control on volcanic plume dynamics, the effects

Assessments for the threats posed by volcanic eruptions rely in large part on the accurate prediction of volcanic plume motion over time. That predictive capacity is currently hindered by a limited understanding of volcanic plume dynamics. While eruption rate is considered a dominant control on volcanic plume dynamics, the effects of variable eruption rates on plume rise and evolution are not well understood. To address this aspect of plume dynamics, I conducted an experimental investigation wherein I quantified the relationship between laboratory jet development and highly-variable discharge rates under conditions analogous to those which may prevail in unsteady, short-lived explosive eruptions. I created turbulent jets in the laboratory by releasing pressurized water into a tank of still water. I then measured the resultant jet growth over time using simple video images and particle image velocimetry (PIV). I investigated jet behavior over a range of jet Reynolds numbers which overlaps with estimates of Reynolds numbers for short-duration volcanic plumes. By analysis of the jet boundary and velocity field evolution, I discovered a direct relationship between changes in vent conditions and jet evolution. Jet behavior evolved through a sequence of three stages - jet-like, transitional, and puff-like - that correlate with three main injection phases - acceleration, deceleration and off. While the source was off, jets were characterized by relatively constant internal velocity distributions and flow propagation followed that of a classical puff. However, while the source was on, the flow properties - both in the flows themselves and in the induced ambient flow - changed abruptly with changes at the source. On the basis of my findings for unsteady laboratory jets, I conclude that variable eruption rates with characteristic time scales close to eruption duration have first-order control over volcanic plume evolution. Prior to my study, the significance of this variation was largely uncharacterized as the volcanology community predominately uses steady eruption models for interpretation and prediction of activity. My results suggest that unsteady models are necessary to accurately interpret behavior and assess threats from unsteady, short-lived eruptions.
ContributorsChojnicki, Kirsten (Author) / Clarke, Amanda (Thesis advisor) / Williams, Stanley (Committee member) / Adrian, Ronald (Committee member) / Phillips, Jeremy (Committee member) / Fernando, Harindra (Committee member) / Arizona State University (Publisher)
Created2012
Description

Particle Image Velocimetry (PIV) has become a cornerstone of modern experimental fluid mechanics due to its unique ability to resolve the entire instantaneous two-dimensional velocity field of an experimental flow. However, this methodology has historically been omitted from undergraduate curricula due to the significant cost of research-grade PIV systems and

Particle Image Velocimetry (PIV) has become a cornerstone of modern experimental fluid mechanics due to its unique ability to resolve the entire instantaneous two-dimensional velocity field of an experimental flow. However, this methodology has historically been omitted from undergraduate curricula due to the significant cost of research-grade PIV systems and safety considerations stemming from the high-power Nd-YAG lasers typically implemented by PIV systems. In the following undergraduate thesis, a low-cost model of a PIV system is designed to be used within the context of an undergraduate fluid mechanics lab. The proposed system consists of a Hele-Shaw water tunnel, a high-power LED lighting source, and a modern smartphone camera. Additionally, a standalone application was developed to perform the necessary image processing as well as to perform Particle Streak Velocimetry (PSV) and PIV image analysis. Ultimately, the proposed system costs $229.33 and can replicate modern PIV techniques albeit for simple flow scenarios.

ContributorsZamora, Matthew Alan (Author) / Adrian, Ronald (Thesis director) / Kim, Jeonglae (Committee member) / Mechanical and Aerospace Engineering Program (Contributor) / Barrett, The Honors College (Contributor)
Created2021-05