Matching Items (6)
Filtering by

Clear all filters

149728-Thumbnail Image.png
Description
In geotechnical engineering, measuring the unsaturated hydraulic conductivity of fine grained soils can be time consuming and tedious. The various applications that require knowledge of the unsaturated hydraulic conductivity function are great, and in geotechnical engineering, they range from modeling seepage through landfill covers to determining infiltration of water

In geotechnical engineering, measuring the unsaturated hydraulic conductivity of fine grained soils can be time consuming and tedious. The various applications that require knowledge of the unsaturated hydraulic conductivity function are great, and in geotechnical engineering, they range from modeling seepage through landfill covers to determining infiltration of water under a building slab. The unsaturated hydraulic conductivity function can be measured using various direct and indirect techniques. The instantaneous profile method has been found to be the most promising unsteady state method for measuring the unsaturated hydraulic conductivity function for fine grained soils over a wide range of suction values. The instantaneous profile method can be modified by using different techniques to measure suction and water content and also through the way water is introduced or removed from the soil profile. In this study, the instantaneous profile method was modified by creating duplicate soil samples compacted into cylindrical tubes at two different water contents. The techniques used in the duplicate method to measure the water content and matric suction included volumetric moisture probes, manual water content measurements, and filter paper tests. The experimental testing conducted in this study provided insight into determining the unsaturated hydraulic conductivity using the instantaneous profile method for a sandy clay soil and recommendations are provided for further evaluation. Overall, this study has demonstrated that the presence of cracks has no significant impact on the hydraulic behavior of soil in high suction ranges. The results of this study do not examine the behavior of cracked soil unsaturated hydraulic conductivity at low suction and at moisture contents near saturation.
ContributorsJacquemin, Sean Christopher (Author) / Zapata, Claudia (Thesis advisor) / Houston, Sandra (Committee member) / Kavazanjian, Edward (Committee member) / Arizona State University (Publisher)
Created2011
150101-Thumbnail Image.png
Description
As a prelude to a study on the post-liquefaction properties and structure of soil, an investigation of ground freezing as an undisturbed sampling technique was conducted to investigate the ability of this sampling technique to preserve soil structure and properties. Freezing the ground is widely regarded as an appropriate technique

As a prelude to a study on the post-liquefaction properties and structure of soil, an investigation of ground freezing as an undisturbed sampling technique was conducted to investigate the ability of this sampling technique to preserve soil structure and properties. Freezing the ground is widely regarded as an appropriate technique to recover undisturbed samples of saturated cohesionless soil for laboratory testing, despite the fact that water increases in volume when frozen. The explanation generally given for the preservation of soil structure using the freezing technique was that, as long as the freezing front advanced uni-directionally, the expanding pore water is expelled ahead of the freezing front as the front advances. However, a literature review on the transition of water to ice shows that the volume of ice expands approximately nine percent after freezing, bringing into question the hypothesized mechanism and the ability of a frozen and then thawed specimen to retain the properties and structure of the soil in situ. Bench-top models were created by pluviation of sand. The soil in the model was then saturated and subsequently frozen. Freezing was accomplished using a pan filled with alcohol and dry ice placed on the surface of the sand layer to induce a unidirectional freezing front in the sample container. Coring was used to recover frozen samples from model containers. Recovered cores were then placed in a triaxial cell, thawed, and subjected to consolidated undrained loading. The stress-strain-strength behavior of the thawed cores was compared to the behavior of specimens created in a split mold by pluviation and then saturated and sheared without freezing and thawing. The laboratory testing provide insight to the impact of freezing and thawing on the properties of cohesionless soil.
ContributorsKatapa, Kanyembo (Author) / Kavazanjian, Edward (Thesis advisor) / Houston, Sandra (Committee member) / Zapata, Claudia (Committee member) / Arizona State University (Publisher)
Created2011
154167-Thumbnail Image.png
Description
The influence of temperature on soil engineering properties is a major concern in the design of engineering systems such as radioactive waste disposal barriers, ground source heat pump systems and pavement structures. In particular, moisture redistribution under pavement systems might lead to changes in unbound material stiffness that will affect

The influence of temperature on soil engineering properties is a major concern in the design of engineering systems such as radioactive waste disposal barriers, ground source heat pump systems and pavement structures. In particular, moisture redistribution under pavement systems might lead to changes in unbound material stiffness that will affect pavement performance. Accurate measurement of thermal effects on unsaturated soil hydraulic properties may lead to reduction in design and construction costs. This thesis presents preliminary results of an experimental study aimed at determining the effect of temperature on the soil water characteristic curve (SWCC) and the unsaturated hydraulic conductivity function (kunsat). Pressure plate devices with volume change control were used to determine the SWCC and the instantaneous profile method was used to obtain the kunsat function. These properties were measured on two fine-grained materials subjected to controlled temperatures of 5oC, 25oC and 40oC. The results were used to perform a sensitivity analysis of the effect of temperature changes on the prediction of moisture movement under a covered area. In addition, two more simulations were performed where changes in hydraulic properties were done in a stepwise fashion. The findings were compared to field measured water content data obtained on the subgrade material of the FAA William Hughes test facility located in Atlantic City. Results indicated that temperature affects the unsaturated hydraulic properties of the two soils used in the study. For the DuPont soil, a soil with high plasticity, it was found that the water retention was higher at low temperatures for suction levels lower than about 10,000 kPa; while the kunsat functions at the three temperatures were not significantly different. For the County soil, a material with medium plasticity, it was found that it holds around 10% more degree of saturation at 5°C than that at 40°C for suction levels higher than about 1,000 kPa; while the hydraulic conductivity at 40°C was at least one order of magnitude higher than that at 5°C, for suction levels higher than 1,000 kPa. These properties were used to perform two types of numerical analyses: a sensitivity analysis and stepwise analysis. Absolute differences between predicted and field measured data were considered to be acceptable, ranging from 4.5% to 9% for all simulations. Overall results show an improvement in predictions when non-isothermal conditions were used over the predictions obtained with isothermal conditions.
ContributorsLu, Yutong (Author) / Zapata, Claudia E (Thesis advisor) / Kavazanjian, Edward (Committee member) / Houston, Sandra L. (Committee member) / Arizona State University (Publisher)
Created2015
135563-Thumbnail Image.png
Description
This dissertation details an attempt to experimentally evaluate the Giroud et al. (1995) concentration factors for geomembranes loaded in tension perpendicular to a seam by laboratory measurement. Field observations of the performance of geomembrane liner systems indicates that tears occur at average strains well below the yield criteria. These observations

This dissertation details an attempt to experimentally evaluate the Giroud et al. (1995) concentration factors for geomembranes loaded in tension perpendicular to a seam by laboratory measurement. Field observations of the performance of geomembrane liner systems indicates that tears occur at average strains well below the yield criteria. These observations have been attributed, in part, to localized strain concentrations in the geomembrane loaded in tension in a direction perpendicular to the seam. Giroud et al. (1995) has presented theoretical strain concentration factors for geomembrane seams loaded in tension when the seam is perpendicular to the applied tensile strain. However, these factors have never been verified. This dissertation was prepared in fulfillment of the requirements for graduation from Barrett, the Honors College at Arizona State University. The work described herein was sponsored by the National Science Foundation as a part of a larger research project entitled "NEESR: Performance Based Design of Geomembrane Liner Systems Subject to Extreme Loading." The work is motivated by geomembrane tears observed at the Chiquita Canyon landfill following the 1994 Northridge earthquake. Numerical analysis of the strains in the Chiquita Canyon landfill liner induced by the earthquake indicated that the tensile strains, were well below the yield strain of the geomembrane material. In order to explain why the membrane did fail, strain concentration factors due to bending at seams perpendicular to the load in the model proposed by Giroud et al. (1995) had to be applied to the geomembrane (Arab, 2011). Due to the localized nature of seam strain concentrations, digital image correlation (DIC) was used. The high resolution attained with DIC had a sufficient resolution to capture the localized strain concentrations. High density polyethylene (HDPE) geomembrane samples prepared by a leading geomembrane manufacturer were used in the testing described herein. The samples included both extrusion fillet and dual hot wedge fusion seams. The samples were loaded in tension in a standard triaxial test apparatus. to the seams in the samples including both extrusion fillet and dual hot wedge seams. DIC was used to capture the deformation field and strain fields were subsequently created by computer analysis.
ContributorsAndresen, Jake Austin (Author) / Kavazanjian, Edward (Thesis director) / Gutierrez, Angel (Committee member) / Civil, Environmental and Sustainable Engineering Programs (Contributor) / Barrett, The Honors College (Contributor)
Created2016-05
154863-Thumbnail Image.png
Description
The understanding of multiphase fluid flow in porous media is of great importance in many fields such as enhanced oil recovery, hydrology, CO2 sequestration, contaminants cleanup, and natural gas production from hydrate bearing sediments.

In this study, first, the water retention curve (WRC) and relative permeability in hydrate bearing sediments

The understanding of multiphase fluid flow in porous media is of great importance in many fields such as enhanced oil recovery, hydrology, CO2 sequestration, contaminants cleanup, and natural gas production from hydrate bearing sediments.

In this study, first, the water retention curve (WRC) and relative permeability in hydrate bearing sediments are explored to obtain fitting parameters for semi-empirical equations. Second, immiscible fluid invasion into porous media is investigated to identify fluid displacement pattern and displacement efficiency that are affected by pore size distribution and connectivity. Finally, fluid flow through granular media is studied to obtain fluid-particle interaction. This study utilizes the combined techniques of discrete element method simulation, micro-focus X-ray computed tomography (CT), pore-network model simulation algorithms for gas invasion, gas expansion, and relative permeability calculation, transparent micromodels, and water retention curve measurement equipment modified for hydrate-bearing sediments. In addition, a photoelastic disk set-up is fabricated and the image processing technique to correlate the force chain to the applied contact forces is developed.

The results show that the gas entry pressure and the capillary pressure increase with increasing hydrate saturation. Fitting parameters are suggested for different hydrate saturation conditions and morphologies. And, a new model for immiscible fluid invasion and displacement is suggested in which the boundaries of displacement patterns depend on the pore size distribution and connectivity. Finally, the fluid-particle interaction study shows that the fluid flow increases the contact forces between photoelastic disks in parallel direction with the fluid flow.
ContributorsMahabadi, Nariman (Author) / Jang, Jaewon (Thesis advisor) / Zapata, Claudia (Committee member) / Kavazanjian, Edward (Committee member) / Arizona State University (Publisher)
Created2016
155622-Thumbnail Image.png
Description
Laboratory testing was conducted to quantify strain concentrations adjacent to seams and scratches in high density polyethylene (HDPE) geomembranes. The tensile strain profile of remnants meeting the ASTM criteria for wide-width tensile testing from samples of field seams recovered for construction quality assurance testing was evaluated using digital image correlation

Laboratory testing was conducted to quantify strain concentrations adjacent to seams and scratches in high density polyethylene (HDPE) geomembranes. The tensile strain profile of remnants meeting the ASTM criteria for wide-width tensile testing from samples of field seams recovered for construction quality assurance testing was evaluated using digital image correlation (DIC). Strains adjacent to scratches on laboratory prepared samples loaded in tension were also measured using DIC. The tensile strain in the zone adjacent to a seam and the tensile strain adjacent to a scratch were compared to the tensile strains calculated using theoretical strain concentration factors. The relationship between the maximum tensile strain adjacent to a seam and the global nominal strain in the sample was quantified for textured and smooth geomembranes of common thicknesses. Using statistical analysis of the data, bounds were developed for the allowable nominal tensile strain expected to induce maximum tensile strains adjacent to the seam less than or equal to the typical yield strain of HDPE geomembranes, at several confidence levels. Where nominal strain is the global or average strain applied to the sample and maximum strain is the largest tensile strain induced in the sample.

The reduction in the nominal yield strain due to a scratch in a HDPE geomembrane was also quantified. The yield strain was approximately the same as predicted using theoretical strain concentration factors. The difference in the average measured maximum strains adjacent to the seams of textured and smooth HDPE geomembranes was found to be statistically insignificant. However, maximum strains adjacent to extrusion welded seams were somewhat greater than adjacent to fusion welded seams for nominal strains on the order of 3% to 4%. The results of the testing program suggest that the nominal tensile strain should be limited to 4% around dual hot wedge seams and 3% around extrusion fillet seams to avoid maximum strains equal to 11%, a typical yield strain for HDPE geomembranes.
ContributorsAndresen, Jake (Author) / Kavazanjian, Edward (Thesis advisor) / Houston, Sandra (Committee member) / Zapata, Claudia (Committee member) / Arizona State University (Publisher)
Created2017