Matching Items (3)
Filtering by

Clear all filters

153035-Thumbnail Image.png
Description
Dimensional Metrology is the branch of science that determines length, angular, and geometric relationships within manufactured parts and compares them with required tolerances. The measurements can be made using either manual methods or sampled coordinate metrology (Coordinate measuring machines). Manual measurement methods have been in practice for a long time

Dimensional Metrology is the branch of science that determines length, angular, and geometric relationships within manufactured parts and compares them with required tolerances. The measurements can be made using either manual methods or sampled coordinate metrology (Coordinate measuring machines). Manual measurement methods have been in practice for a long time and are well accepted in the industry, but are slow for the present day manufacturing. On the other hand CMMs are relatively fast, but these methods are not well established yet. The major problem that needs to be addressed is the type of feature fitting algorithm used for evaluating tolerances. In a CMM the use of different feature fitting algorithms on a feature gives different values, and there is no standard that describes the type of feature fitting algorithm to be used for a specific tolerance. Our research is focused on identifying the feature fitting algorithm that is best used for each type of tolerance. Each algorithm is identified as the one to best represent the interpretation of geometric control as defined by the ASME Y14.5 standard and on the manual methods used for the measurement of a specific tolerance type. Using these algorithms normative procedures for CMMs are proposed for verifying tolerances. The proposed normative procedures are implemented as software. Then the procedures are verified by comparing the results from software with that of manual measurements.

To aid this research a library of feature fitting algorithms is developed in parallel. The library consists of least squares, Chebyshev and one sided fits applied on the features of line, plane, circle and cylinder. The proposed normative procedures are useful for evaluating tolerances in CMMs. The results evaluated will be in accordance to the standard. The ambiguity in choosing the algorithms is prevented. The software developed can be used in quality control for inspection purposes.
ContributorsVemulapalli, Prabath (Author) / Shah, Jami J. (Thesis advisor) / Davidson, Joseph K. (Committee member) / Takahashi, Timothy (Committee member) / Arizona State University (Publisher)
Created2014
153961-Thumbnail Image.png
Description
Background: Heart failure is the leading cause of hospitalization in older adults and has the highest 30-day readmission rate of all diagnoses. An estimated 30 to 60 percent of older adults lose some degree of physical function in the course of an acute hospital stay. Few studies have addressed the

Background: Heart failure is the leading cause of hospitalization in older adults and has the highest 30-day readmission rate of all diagnoses. An estimated 30 to 60 percent of older adults lose some degree of physical function in the course of an acute hospital stay. Few studies have addressed the role of posture and mobility in contributing to, or improving, physical function in older hospitalized adults. No study to date that we are aware of has addressed this in the older heart failure population.

Purpose: To investigate the predictive value of mobility during a hospital stay and patterns of mobility during the month following discharge on hospital readmission and 30-day changes in functional status in older heart failure patients.

Methods: This was a prospective observational study of 21 older (ages 60+) patients admitted with a primary diagnosis of heart failure. Patients wore two inclinometric accelerometers (rib area and thigh) to record posture and an accelerometer placed at the ankle to record ambulatory activity. Patients wore all sensors continuously during hospitalization and the ankle accelerometer for 30 days after hospital discharge. Function was assessed in all patients the day after hospital discharge and again at 30 days post-discharge.

Results: Five patients (23.8%) were readmitted within the 30 day post-discharge period. None of the hospital or post-discharge mobility measures were associated with readmission after adjustment for covariates. Higher percent lying time in the hospital was associated with slower Timed Up and Go (TUG) time (b = .08, p = .01) and poorer hand grip strength (b = -13.94, p = .02) at 30 days post-discharge. Higher daily stepping activity during the 30 day post-discharge period was marginally associated with improvements in SPPB scores at 30 days (b = <.001, p = .06).

Conclusion: For older heart failure patients, increased time lying while hospitalized is associated with slower walking time and poor hand grip strength 30 days after discharge. Higher daily stepping after discharge may be associated with improvements in physical function at 30 days.
ContributorsFloegel, Theresa A (Author) / Buman, Matthew P (Thesis advisor) / Hooker, Steven (Committee member) / Dickinson, Jared (Committee member) / DerAnanian, Cheryl (Committee member) / McCarthy, Marianne (Committee member) / Arizona State University (Publisher)
Created2015
155684-Thumbnail Image.png
Description
Having accurate measurements of sedentary behaviors is important to understand relationships between sedentary behaviors and health outcomes and to evaluate changes in interventions and health promotion programs designed to reduce sedentary behaviors. This dissertation included three projects that examined measurement properties of wearable monitors used to measure sedentary behaviors. Project

Having accurate measurements of sedentary behaviors is important to understand relationships between sedentary behaviors and health outcomes and to evaluate changes in interventions and health promotion programs designed to reduce sedentary behaviors. This dissertation included three projects that examined measurement properties of wearable monitors used to measure sedentary behaviors. Project one examined the validity of three monitors: the ActiGraph GT3X+, activPAL™, and SenseWear 2. None of the monitors were equivalent with the criterion measure of oxygen uptake to estimate the energy cost of sedentary and light-intensity activities. The ActivPAL™ had the best accuracy as compared with the other monitors. In project two, the accuracy of ActiGraph GT3X+and GENEActiv cut-points used to assess sedentary behavior were compared with direct observation during free-living conditions. New vector magnitude cut-points also were developed to classify time spent in sedentary- and stationary behaviors during free-living conditions. The cut-points tested had modest overall accuracy to classify sedentary time as compared to direct observation. New ActiGraph 1-minute vector cut-points increased overall accuracy for classifying sedentary time. Project 3 examined the accuracy of the sedentary sphere by testing various arm elevation- and movement-count configurations using GENEActiv and ActiGraph GT3X+ data obtained during free-living conditions. None of the configurations were equivalent to the criterion measure of direct observation. The best configuration of the GENEActiv was: worn on the dominant wrist at 15 degrees below the horizontal plane with a cut-point <489 for each 15-second interval. The best configuration for the ActiGraph was: worn on the non-dominant wrist at 5° below the horizontal plane with a cut-point of <489 counts for each 15-second interval. Collectively, these findings indicate that the wearable monitors and methods examined in this study are limited in their ability to assess sedentary behaviors and light intensity physical activity. Additional research is needed to further understand the scope and limitations of wearable monitors and methods used to assess sedentary behaviors and light intensity physical activity.
ContributorsFlorez Pregonero, Argemiro Alberto (Author) / Ainsworth, Barbara E (Thesis advisor) / Buman, Matthew P (Committee member) / Hooker, Steven P (Committee member) / Keller, Colleen S (Committee member) / Swan, Pamela (Committee member) / Arizona State University (Publisher)
Created2017