Matching Items (4)
Filtering by

Clear all filters

151476-Thumbnail Image.png
Description
The health benefits of physical activity are widely accepted. Emerging research also indicates that sedentary behaviors can carry negative health consequences regardless of physical activity level. This dissertation explored four projects that examined measurement properties of physical activity and sedentary behavior monitors. Project one identified the oxygen costs of four

The health benefits of physical activity are widely accepted. Emerging research also indicates that sedentary behaviors can carry negative health consequences regardless of physical activity level. This dissertation explored four projects that examined measurement properties of physical activity and sedentary behavior monitors. Project one identified the oxygen costs of four other care activities in seventeen adults. Pushing a wheelchair and pushing a stroller were identified as moderate-intensity activities. Minutes spent engaged in these activities contribute towards meeting the 2008 Physical Activity Guidelines. Project two identified the oxygen costs of common cleaning activities in sixteen adults. Mopping a floor was identified as moderate-intensity physical activity, while cleaning a kitchen and cleaning a bathtub were identified as light-intensity physical activity. Minutes spent engaged in mopping a floor contributes towards meeting the 2008 Physical Activity Guidelines. Project three evaluated the differences in number of minutes spent in activity levels when utilizing different epoch lengths in accelerometry. A shorter epoch length (1-second, 5-seconds) accumulated significantly more minutes of sedentary behaviors than a longer epoch length (60-seconds). The longer epoch length also identified significantly more time engaged in light-intensity activities than the shorter epoch lengths. Future research needs to account for epoch length selection when conducting physical activity and sedentary behavior assessment. Project four investigated the accuracy of four activity monitors in assessing activities that were either sedentary behaviors or light-intensity physical activities. The ActiGraph GT3X+ assessed the activities least accurately, while the SenseWear Armband and ActivPAL assessed activities equally accurately. The monitor used to assess physical activity and sedentary behaviors may influence the accuracy of the measurement of a construct.
ContributorsMeckes, Nathanael (Author) / Ainsworth, Barbara E (Thesis advisor) / Belyea, Michael (Committee member) / Buman, Matthew (Committee member) / Gaesser, Glenn (Committee member) / Wharton, Christopher (Christopher Mack), 1977- (Committee member) / Arizona State University (Publisher)
Created2012
153035-Thumbnail Image.png
Description
Dimensional Metrology is the branch of science that determines length, angular, and geometric relationships within manufactured parts and compares them with required tolerances. The measurements can be made using either manual methods or sampled coordinate metrology (Coordinate measuring machines). Manual measurement methods have been in practice for a long time

Dimensional Metrology is the branch of science that determines length, angular, and geometric relationships within manufactured parts and compares them with required tolerances. The measurements can be made using either manual methods or sampled coordinate metrology (Coordinate measuring machines). Manual measurement methods have been in practice for a long time and are well accepted in the industry, but are slow for the present day manufacturing. On the other hand CMMs are relatively fast, but these methods are not well established yet. The major problem that needs to be addressed is the type of feature fitting algorithm used for evaluating tolerances. In a CMM the use of different feature fitting algorithms on a feature gives different values, and there is no standard that describes the type of feature fitting algorithm to be used for a specific tolerance. Our research is focused on identifying the feature fitting algorithm that is best used for each type of tolerance. Each algorithm is identified as the one to best represent the interpretation of geometric control as defined by the ASME Y14.5 standard and on the manual methods used for the measurement of a specific tolerance type. Using these algorithms normative procedures for CMMs are proposed for verifying tolerances. The proposed normative procedures are implemented as software. Then the procedures are verified by comparing the results from software with that of manual measurements.

To aid this research a library of feature fitting algorithms is developed in parallel. The library consists of least squares, Chebyshev and one sided fits applied on the features of line, plane, circle and cylinder. The proposed normative procedures are useful for evaluating tolerances in CMMs. The results evaluated will be in accordance to the standard. The ambiguity in choosing the algorithms is prevented. The software developed can be used in quality control for inspection purposes.
ContributorsVemulapalli, Prabath (Author) / Shah, Jami J. (Thesis advisor) / Davidson, Joseph K. (Committee member) / Takahashi, Timothy (Committee member) / Arizona State University (Publisher)
Created2014
149587-Thumbnail Image.png
Description
It is broadly accepted that physical activity provides substantial health benefits. Despite strong evidence, approximately 60% to 95% of US adults are insufficiently active to obtain these health benefits. This dissertation explored five projects that examined the measurement properties and methodology for a variety of physical activity assessment methods. Project

It is broadly accepted that physical activity provides substantial health benefits. Despite strong evidence, approximately 60% to 95% of US adults are insufficiently active to obtain these health benefits. This dissertation explored five projects that examined the measurement properties and methodology for a variety of physical activity assessment methods. Project one identified validity evidence for the new MyWellness Key accelerometer in sixteen adults. The MyWellness Key demonstrated acceptable validity evidence when compared to a criterion accelerometer during graded treadmill walking and in free-living settings. This supports the use of the MyWellness Key accelerometer to measure physical activity. Project two evaluated validity (study 1) and test-retest reliability evidence (study 2) of the Global Physical Activity Questionnaire (GPAQ) in a two part study. The GPAQ was compared to direct and indirect criterion measures including object and subjective physical activity instruments. These data provided preliminary validity and reliability evidence for the GPAQ that support its use to assess physical activity. Project three investigated the optimal h.d-1 of accelerometer wear time needed to assess daily physical activity. Using a semi-simulation approach, data from 124 participants were used to compare 10-13 h.d-1 to the criterion 14 h.d-1. This study suggested that a minimum accelerometer wear time of 13 h.d-1 is needed to provide a valid measure of daily physical activity. Project four evaluated validity and reliability evidence of a novel method (Movement and Activity in Physical Space [MAPS] score) that combines accelerometer and GPS data to assess person-environment interactions. Seventy-five healthy adults wore an accelerometer and GPS receiver for three days to provide MAPS scores. This study provided evidence for use of a MAPS score for future research and clinical use. Project five used accelerometer data from 1,000 participants from the 2005-2006 National Health and Nutrition Examination Study. A semi-simulation approach was used to assess the effect of accelerometer wear time (10-14 h.d-1) on physical activity data. These data showed wearing for 12 h.d-1 or less may underestimate time spent in various intensities of physical activity.
ContributorsHerrmann, Stephen (Author) / Ainsworth, Barbara (Thesis advisor) / Gaesser, Glenn (Committee member) / Der Ananian, Cheryl (Committee member) / Kang, Minsoo (Committee member) / Vega-Lopez, Sonia (Committee member) / Arizona State University (Publisher)
Created2011
157636-Thumbnail Image.png
Description
Although researchers often conceptualize shyness as stable across different situations (e.g., Rubin, Coplan, & Bowker, 2009), evidence has suggested that shyness may consist of situation-specific components (e.g., Asendorpf, 1990a; 1990b; Gazelle & Faldowski, 2014; Xu & Farver, 2009). This study was aimed at developing a systematic measurement tool for situational

Although researchers often conceptualize shyness as stable across different situations (e.g., Rubin, Coplan, & Bowker, 2009), evidence has suggested that shyness may consist of situation-specific components (e.g., Asendorpf, 1990a; 1990b; Gazelle & Faldowski, 2014; Xu & Farver, 2009). This study was aimed at developing a systematic measurement tool for situational shyness in adolescence, as well as examining the relations between situational shyness and other popular measures of shyness and between situational shyness and adjustment. A sample of Chinese adolescents (N = 492) from an urban school participated in the study during 7th (T1) and 8th (T2) grades. Adolescents self-reported their situational shyness using a new measure of hypothetical scenarios, as well as their general shyness, anxious shyness, regulated shyness, depressive symptoms, and loneliness. Peers reported adolescents’ general and conflicted shyness, and popularity and peer rejection. The school provided records of their academic achievement (exam scores).

Exploratory and confirmatory factor analyses of the situational shyness measure consistently supported that shyness in the hypothetical scenarios can be separated into three components: shyness with familiar peers, shyness with unfamiliar peers, and shyness in formal situations. These components had differential associations with other measures of shyness. Self-reported general and anxious shyness were related consistently to shyness with unfamiliar peers and in formal situations, and occasionally to shyness with familiar peers. Self-reported regulated shyness was not related to self-reported shyness in any situation. Peer-reported conflicted shyness was associated with shyness with familiar and unfamiliar peers, whereas peer-reported general shyness was associated with shyness with unfamiliar peers and in formal situations. Moreover, situational shyness showed differential relations to maladjustment. Shyness with familiar peers was associated positively with maladjustment in multiple domains, especially academic and peer difficulties. Shyness with unfamiliar peers and shyness in formal situations, in contrast, were associated primarily with internalizing problems. In addition, shyness with unfamiliar peers and in formal situations occasionally related to positive adjustment, suggesting shyness in specific situations may still be protective in contemporary urban China. The findings provided new evidence that the correlates of shyness depend on the situation in which shyness occurs, and may inform future intervention programs.
ContributorsAn, Danming (Author) / Eggum-Wilkens, Natalie D (Thesis advisor) / Spinrad, Tracy L (Committee member) / Eisenberg, Nancy (Committee member) / Lemery-Chalfant, Kathryn (Committee member) / Arizona State University (Publisher)
Created2019